title: "Jinko Solar Co Ltd JKM475M-7RL3 Specs (475.0W, 52.24V Voc)"
url: https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm475m-7rl3/
description: "CEC datasheet for Jinko Solar Co Ltd JKM475M-7RL3: 475.0W STC, 52.24V Voc, 17-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Jinko Solar Co Ltd JKM475M-7RL3 — CEC Solar Module Specifications

Manufacturer: [**Jinko Solar Co Ltd**](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

Jinko Solar Co Ltd JKM475M-7RL3 is a 475.0 W STC (439.0 W PTC) Mono-c-Si solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 21.79% efficiency, 52.24 V Voc at 25 C, and 57.87 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 475.0 W

- **PTC Wattage** : 439.0 W

- **Voc @ 25C** : 52.24 V

- **Efficiency** : 21.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKM475M-7RL3 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM475M-7RL3 (Mono-c-Si) residential solar systems.

Homeowners evaluating Jinko Solar Co Ltd JKM475M-7RL3 need 13 panels for 6 kW or 17 panels (399 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 17 panels (399 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.308%/C) pushes open-circuit voltage to 57.87 V at 14 F and 59.48 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Jinko Solar Co Ltd JKM475M-7RL3 Fall Across Listed CEC Models?

Comparison of Jinko Solar Co Ltd JKM475M-7RL3 (475.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKM475M-7RL3?

Relative ranking of Jinko Solar Co Ltd JKM475M-7RL3 across nameplate watts, 92.4% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM475M-7RL3?

Summary of Jinko Solar Co Ltd JKM475M-7RL3 output rank, 8 kW array size (17 panels), efficiency rating, and 600 V string limit.

Rank #4,892 / 21,677

### Top 22.9% STC Output

475.0 W STC (+90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,590

### 21.79% Aperture Efficiency

Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.87 V at -10 C (578.7 V string) and 59.48 V at -20 C (10 max).

 8 kW Reference Array

### 17 Panels = 8,075 W STC

Occupies 37.1 m2 (399 sq ft) producing 7,463 W PTC; NEC 690.8 OCPD floor is 18.36 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.24 * (1 + (-0.308/100) * (-10 - 25)) = 57.87 V | OCPD = 1.56 * 11.77 = 18.36 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM475M-7RL3: Voc=52.24 V, beta_Voc=-0.308%/C, Isc=11.77 A, STC=475.0 W, Area=2.18 m2.

**Result:** 10 panels max on 600 V (578.7 V); 17 panels for 8 kW (399 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM475M-7RL3?

Complete CEC test sheet for Jinko Solar Co Ltd JKM475M-7RL3 including Isc (11.77 A), Voc (52.24 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM475M-7RL3.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 475.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 439.0 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.24 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.38 V / 10.95 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.308 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.79% (2.18 m2) | Array roof footprint density |
| **Cell Count & Technology** | 26 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jinko Solar Co Ltd JKM475M-7RL3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM475M-7RL3.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.17 kW | 305 sq ft | $1,544 | $2,611 |
| **8 kW Class** | 17 | 8.07 kW | 399 sq ft | $2,020 | $3,415 |
| **10 kW Class** | 22 | 10.45 kW | 516 sq ft | $2,616 | $4,423 |

## How Many Jinko Solar Co Ltd JKM475M-7RL3 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM475M-7RL3 (52.24 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.24V and beta_Voc=-0.308%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.48 V | 10 panels | 594.8 V | 16 panels |
| **-10 C (14 F)** | 57.87 V | 10 panels | 578.7 V | 17 panels |
| **0 C (32 F)** | 56.26 V | 10 panels | 562.6 V | 17 panels |
| **25 C (77 F STC)** | 52.24 V | 11 panels | 574.6 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM475M-7RL3?

Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-470MS (470.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3Y-470MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-470ms/) CSI Solar Co Ltd | 470.0 W | -5.0 W | 52.5 V | 20.52% | 93.5% |
| [**CSI Solar Co Ltd CS3Y-480P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-480p/) CSI Solar Co Ltd | 480.0 W | +5.0 W | 52.8 V | 20.96% | 93.2% |
| [**CSI Solar Co Ltd CS3Y-485MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-485ms/) CSI Solar Co Ltd | 485.0 W | +10.0 W | 53.1 V | 21.18% | 93.6% |
| [**CSI Solar Co Ltd CS3Y-460P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3y-460p/) CSI Solar Co Ltd | 460.0 W | -15.0 W | 52.0 V | 20.09% | 93.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM475M-7RL3?

Evaluate Jinko Solar Co Ltd JKM475M-7RL3 (475.0 W STC, 52.24 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM475M-7RL3 reaches 59.48 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (399 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM475M-7RL3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKM475M-7RL3 8 kW Residential Fit

Needs 17 modules (399 sq ft) with a 20 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-470MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 439.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM475M-7RL3 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Jinko Solar Co Ltd JKM475M-7RL3 PTC wattage (439.0 W) lower than STC (475.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 439.0 W PTC (92.4% retention) across Jinko Solar Co Ltd JKM475M-7RL3's 2.18 m2 aperture.

### Who should skip Jinko Solar Co Ltd JKM475M-7RL3 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 Jinko Solar Co Ltd JKM475M-7RL3 panels (399 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-470MS.

### What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM475M-7RL3?

On 1,000 V commercial inverters at -10 C (57.87 V cold Voc), Jinko Solar Co Ltd JKM475M-7RL3 fits up to 17 panels per series string.

## Related Pages

Compare Jinko Solar Co Ltd equipment, CSI Solar Co Ltd CS3Y-470MS specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKM475M-7RL3.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDX](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/)