title: "Jinko Solar Co Ltd JKM420M-6TL4 Specs (420.0W, 40.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm420m-6tl4/
description: "CEC datasheet for Jinko Solar Co Ltd JKM420M-6TL4: 420.0W STC, 40.7V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Jinko Solar Co Ltd JKM420M-6TL4 — CEC Solar Module Specifications

Manufacturer: [**Jinko Solar Co Ltd**](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

Jinko Solar Co Ltd JKM420M-6TL4 is a 420.0 W STC (384.2 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 20.49% efficiency, 40.7 V Voc at 25 C, and 44.95 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 384.2 W

- **Voc @ 25C** : 40.7 V

- **Efficiency** : 20.49%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKM420M-6TL4 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM420M-6TL4 (Mono-c-Si) residential solar systems.

Homeowners evaluating Jinko Solar Co Ltd JKM420M-6TL4 need 15 panels for 6 kW or 20 panels (441 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (441 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.298%/C) pushes open-circuit voltage to 44.95 V at 14 F and 46.16 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Jinko Solar Co Ltd JKM420M-6TL4 Fall Across Listed CEC Models?

Comparison of Jinko Solar Co Ltd JKM420M-6TL4 (420.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKM420M-6TL4?

Relative ranking of Jinko Solar Co Ltd JKM420M-6TL4 across nameplate watts, 91.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM420M-6TL4?

Summary of Jinko Solar Co Ltd JKM420M-6TL4 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,658

### 20.49% Aperture Efficiency

Power density 204.9 W/m2 (0.58 percentage points above 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.95 V at -10 C (584.4 V string) and 46.16 V at -20 C (12 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 41.0 m2 (441 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 21.04 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.7 * (1 + (-0.298/100) * (-10 - 25)) = 44.95 V | OCPD = 1.56 * 13.49 = 21.04 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM420M-6TL4: Voc=40.7 V, beta_Voc=-0.298%/C, Isc=13.49 A, STC=420.0 W, Area=2.05 m2.

**Result:** 13 panels max on 600 V (584.4 V); 20 panels for 8 kW (441 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM420M-6TL4?

Complete CEC test sheet for Jinko Solar Co Ltd JKM420M-6TL4 including Isc (13.49 A), Voc (40.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM420M-6TL4.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 384.2 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.49 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.31 V / 12.61 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.298 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.49% (2.05 m2) | Array roof footprint density |
| **Cell Count & Technology** | 20 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jinko Solar Co Ltd JKM420M-6TL4 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM420M-6TL4.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 331 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 441 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 530 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?

Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM420M-6TL4 series guide.

Sibling CEC listings grouped into the Jinko Solar Co Ltd JKM420M-6TL4 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Jinko Solar Co Ltd JKM415M-6TL4** | 415.0 W | 379.4 W | 40.62 V | 33.2 V | 20.24% |
| **Jinko Solar Co Ltd JKM420M-6TL4** | 420.0 W | 384.2 W | 40.7 V | 33.31 V | 20.49% |

## How Many Jinko Solar Co Ltd JKM420M-6TL4 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM420M-6TL4 (40.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.7V and beta_Voc=-0.298%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.16 V | 12 panels | 553.9 V | 21 panels |
| **-10 C (14 F)** | 44.95 V | 13 panels | 584.4 V | 22 panels |
| **0 C (32 F)** | 43.73 V | 13 panels | 568.5 V | 22 panels |
| **25 C (77 F STC)** | 40.7 V | 14 panels | 569.8 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM420M-6TL4?

Four comparable CEC modules such as AE Solar GmbH AE420CMD-108BDE (420.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AE Solar GmbH AE420CMD-108BDE**](https://epri-peac.com/solar-equipment/modules/ae-solar-gmbh/ae-solar-gmbh-ae420cmd-108bde/) AE Solar GmbH | 420.0 W | Tie (0 W) | 39.7 V | 21.54% | 94.8% |
| [**DE SOLAR(S) PTE LTD DE420-108BG-182S-N/BB**](https://epri-peac.com/solar-equipment/modules/de-solar-s-pte-ltd/de-solar-s-pte-ltd-de420-108bg-182s-n-bb/) DE SOLAR(S) PTE LTD | 420.0 W | Tie (0 W) | 39.7 V | 21.54% | 94.8% |
| [**Aptos Solar Technology LLC DNA-108-MFN10-420W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-420w/) Aptos Solar Technology LLC | 420.0 W | Tie (0 W) | 38.5 V | 21.65% | 95.0% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-n-420/) Elin Energy (Sirius PV) | 420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM420M-6TL4?

Evaluate Jinko Solar Co Ltd JKM420M-6TL4 (420.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM420M-6TL4 reaches 46.16 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM420M-6TL4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKM420M-6TL4 8 kW Residential Fit

Needs 20 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare AE Solar GmbH AE420CMD-108BDE.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM420M-6TL4 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Jinko Solar Co Ltd JKM420M-6TL4 PTC wattage (384.2 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 384.2 W PTC (91.5% retention) across Jinko Solar Co Ltd JKM420M-6TL4's 2.05 m2 aperture.

### Who should skip Jinko Solar Co Ltd JKM420M-6TL4 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Jinko Solar Co Ltd JKM420M-6TL4 panels (441 sq ft) leave unusable roof gaps vs. AE Solar GmbH AE420CMD-108BDE.

### What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM420M-6TL4?

On 1,000 V commercial inverters at -10 C (44.95 V cold Voc), Jinko Solar Co Ltd JKM420M-6TL4 fits up to 22 panels per series string.

## Related Pages

Compare Jinko Solar Co Ltd equipment, AE Solar GmbH AE420CMD-108BDE specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKM420M-6TL4.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDX](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/)