title: "Jinko Solar Co Ltd Specs (405.0W, 48.45V Voc)"
url: https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm405m-72hl-bdvp/
description: "CEC datasheet for Jinko Solar Co Ltd JKM405M-72HL-BDVP: 405.0W STC, 48.45V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Jinko Solar Co Ltd JKM405M-72HL-BDVP — CEC Solar Module Specifications

Manufacturer: [**Jinko Solar Co Ltd**](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

Jinko Solar Co Ltd JKM405M-72HL-BDVP is a 405.0 W STC (372.8 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.45% efficiency, 48.45 V Voc at 25 C, and 53.76 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 372.8 W

- **Voc @ 25C** : 48.45 V

- **Efficiency** : 20.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKM405M-72HL-BDVP Compare Against Peer CEC Listings?

How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM405M-72HL-BDVP handles rooftop heat (372.8 W PTC), 8 kW sizing, and cold winter string voltage.

Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKM405M-72HL-BDVP (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 204.5 W/m2 (0.54 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3U-405MB-AG (405.0 W), this model holds strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677). Higher 48.45 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 16.66 A overcurrent floor served by a 20 A breaker.

## Where Does Jinko Solar Co Ltd JKM405M-72HL-BDVP Fall Across Listed CEC Models?

Where Jinko Solar Co Ltd JKM405M-72HL-BDVP (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKM405M-72HL-BDVP?

Percentile placement of Jinko Solar Co Ltd JKM405M-72HL-BDVP across power density (204.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM405M-72HL-BDVP?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM405M-72HL-BDVP specifications.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,829

### 20.45% Aperture Efficiency

Power density 204.5 W/m2 (0.54 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.76 V at -10 C (591.4 V string) and 55.27 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,456 W PTC; NEC 690.8 OCPD floor is 16.66 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.45 * (1 + (-0.313/100) * (-10 - 25)) = 53.76 V | OCPD = 1.56 * 10.68 = 16.66 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM405M-72HL-BDVP: Voc=48.45 V, beta_Voc=-0.313%/C, Isc=10.68 A, STC=405.0 W, Area=1.98 m2.

**Result:** 11 panels max on 600 V (591.4 V); 20 panels for 8 kW (426 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM405M-72HL-BDVP?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM405M-72HL-BDVP.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM405M-72HL-BDVP.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 372.8 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.19 V / 10.08 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.313 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.45% (1.98 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Jinko Solar Co Ltd JKM405M-72HL-BDVP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM405M-72HL-BDVP (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 320 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 426 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 533 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?

All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKM405M-72HL-BDVP architecture.

Sibling CEC listings grouped into the Jinko Solar Co Ltd JKM405M-72HL-BDVP wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Jinko Solar Co Ltd JKM400M-72HL-BDVP** | 400.0 W | 368.1 W | 48.35 V | 40.01 V | 20.2% |
| **Jinko Solar Co Ltd JKM405M-72HL-BDVP** | 405.0 W | 372.8 W | 48.45 V | 40.19 V | 20.45% |

## How Many Jinko Solar Co Ltd JKM405M-72HL-BDVP Modules Fit in a Cold-Weather String?

Maximum series module counts for Jinko Solar Co Ltd JKM405M-72HL-BDVP from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.45V and beta_Voc=-0.313%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.27 V | 10 panels | 552.7 V | 18 panels |
| **-10 C (14 F)** | 53.76 V | 11 panels | 591.4 V | 18 panels |
| **0 C (32 F)** | 52.24 V | 11 panels | 574.6 V | 19 panels |
| **25 C (77 F STC)** | 48.45 V | 12 panels | 581.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM405M-72HL-BDVP?

Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM405M-72HL-BDVP (405.0 W), including CSI Solar Co Ltd CS3U-405MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-405MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-405mb-ag/) CSI Solar Co Ltd | 405.0 W | Tie (0 W) | 49.3 V | 20.56% | 92.9% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.15% | 93.4% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf-dg/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.05% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc-bf/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.76% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM405M-72HL-BDVP?

Evaluate Jinko Solar Co Ltd JKM405M-72HL-BDVP (405.0 W STC, 48.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM405M-72HL-BDVP reaches 55.27 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM405M-72HL-BDVP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKM405M-72HL-BDVP 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3U-405MB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 372.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM405M-72HL-BDVP by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM405M-72HL-BDVP?

Multiplying Jinko Solar Co Ltd JKM405M-72HL-BDVP's 10.68 A short-circuit current by 1.56 equals 16.66 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Jinko Solar Co Ltd JKM405M-72HL-BDVP pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.76 V cold Voc at 14 F and handles 10.68 A Isc; string inverters cap Jinko Solar Co Ltd JKM405M-72HL-BDVP at 11 panels on 600 V.

### Is Jinko Solar Co Ltd JKM405M-72HL-BDVP eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM405M-72HL-BDVP rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jinko Solar Co Ltd equipment, CSI Solar Co Ltd CS3U-405MB-AG specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKM405M-72HL-BDVP.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDX](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/)