Jinko Solar Co Ltd JKM400N-6RL3-V is a 400.0 W STC (369.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 21.62% efficiency, 45.25 V Voc at 25 C, and 50.03 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 369.2 W

- **Voc @ 25C** : 45.25 V

- **Efficiency** : 21.62%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKM400N-6RL3-V Compare Against Peer CEC Listings?

How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM400N-6RL3-V handles rooftop heat (369.2 W PTC), 8 kW sizing, and cold winter string voltage.

Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKM400N-6RL3-V (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 216.2 W/m2 (1.71 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3N-405MS {Wht} (405.0 W), this model holds strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Mid-range 45.25 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 18.3 A overcurrent floor served by a 20 A breaker.

## Where Does Jinko Solar Co Ltd JKM400N-6RL3-V Fall Across Listed CEC Models?

Where Jinko Solar Co Ltd JKM400N-6RL3-V (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKM400N-6RL3-V?

Percentile placement of Jinko Solar Co Ltd JKM400N-6RL3-V across power density (216.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM400N-6RL3-V?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM400N-6RL3-V specifications.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,097

### 21.62% Aperture Efficiency

Power density 216.2 W/m2 (1.71 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.03 V at -10 C (550.3 V string) and 51.4 V at -20 C (11 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 37.0 m2 (398 sq ft) producing 7,384 W PTC; NEC 690.8 OCPD floor is 18.3 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.25 * (1 + (-0.302/100) * (-10 - 25)) = 50.03 V | OCPD = 1.56 * 11.73 = 18.3 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM400N-6RL3-V: Voc=45.25 V, beta_Voc=-0.302%/C, Isc=11.73 A, STC=400.0 W, Area=1.85 m2.

**Result:** 11 panels max on 600 V (550.3 V); 20 panels for 8 kW (398 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM400N-6RL3-V?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM400N-6RL3-V.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM400N-6RL3-V.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 369.2 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.24 V / 11.04 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.302 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.62% (1.85 m2) | Array roof footprint density |
| **Cell Count & Technology** | 22 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jinko Solar Co Ltd JKM400N-6RL3-V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM400N-6RL3-V (400.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 299 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 398 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 498 sq ft | $2,503 | $4,232 |

## How Many Jinko Solar Co Ltd JKM400N-6RL3-V Modules Fit in a Cold-Weather String?

Maximum series module counts for Jinko Solar Co Ltd JKM400N-6RL3-V from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.25V and beta_Voc=-0.302%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.4 V | 11 panels | 565.4 V | 19 panels |
| **-10 C (14 F)** | 50.03 V | 11 panels | 550.3 V | 19 panels |
| **0 C (32 F)** | 48.67 V | 12 panels | 584.0 V | 20 panels |
| **25 C (77 F STC)** | 45.25 V | 13 panels | 588.2 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM400N-6RL3-V?

Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM400N-6RL3-V (400.0 W), including CSI Solar Co Ltd CS3N-405MS {Wht}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3N-405MS {Wht}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3n-405ms-wht/) CSI Solar Co Ltd | 405.0 W | +5.0 W | 44.7 V | 20.56% | 93.5% |
| [**CSI Solar Co Ltd CS3N-410MS {Blk}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3n-410ms-blk/) CSI Solar Co Ltd | 410.0 W | +10.0 W | 44.9 V | 20.81% | 93.5% |
| [**Boviet Solar Technology Co Ltd BVM6612M-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM400N-6RL3-V?

Evaluate Jinko Solar Co Ltd JKM400N-6RL3-V (400.0 W STC, 45.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM400N-6RL3-V reaches 51.4 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 398 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (398 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM400N-6RL3-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKM400N-6RL3-V 8 kW Residential Fit

Needs 20 modules (398 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM400N-6RL3-V by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM400N-6RL3-V?

Multiplying Jinko Solar Co Ltd JKM400N-6RL3-V's 11.73 A short-circuit current by 1.56 equals 18.3 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Jinko Solar Co Ltd JKM400N-6RL3-V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.03 V cold Voc at 14 F and handles 11.73 A Isc; string inverters cap Jinko Solar Co Ltd JKM400N-6RL3-V at 11 panels on 600 V.

### Is Jinko Solar Co Ltd JKM400N-6RL3-V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM400N-6RL3-V rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jinko Solar Co Ltd equipment, CSI Solar Co Ltd CS3N-405MS {Wht} specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKM400N-6RL3-V.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDX](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/)