title: "Jinko Solar Co Ltd JKM360M-72H-V Specs (360.0W, 48.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm360m-72h-v/
description: "CEC datasheet for Jinko Solar Co Ltd JKM360M-72H-V: 360.0W STC, 48.0V Voc, 23-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Jinko Solar Co Ltd JKM360M-72H-V — CEC Solar Module Specifications

Manufacturer: [**Jinko Solar Co Ltd**](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) Registry: **CEC Verified Engineering Specification**

Jinko Solar Co Ltd JKM360M-72H-V is a 360.0 W STC (331.0 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.95% efficiency, 48.0 V Voc at 25 C, and 53.66 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 360.0 W

- **PTC Wattage** : 331.0 W

- **Voc @ 25C** : 48.0 V

- **Efficiency** : 18.95%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jinko Solar Co Ltd JKM360M-72H-V Compare Against Peer CEC Listings?

Solar engineering breakdown for Jinko Solar Co Ltd JKM360M-72H-V: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Jinko Solar Co Ltd and peers, Jinko Solar Co Ltd JKM360M-72H-V stands 50.0 W below the 410.0 W Mono-c-Si median and strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Higher 48.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does Jinko Solar Co Ltd JKM360M-72H-V Fall Across Listed CEC Models?

Distribution marker showing Jinko Solar Co Ltd JKM360M-72H-V (360.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Jinko Solar Co Ltd JKM360M-72H-V?

Dataset percentiles tracking Jinko Solar Co Ltd JKM360M-72H-V power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM360M-72H-V?

Benchmark highlights for Jinko Solar Co Ltd JKM360M-72H-V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,385 / 21,677

### 360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,547

### 18.95% Aperture Efficiency

Power density 189.5 W/m2 (0.96 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.66 V at -10 C (590.3 V string) and 55.28 V at -20 C (10 max).

 8 kW Reference Array

### 23 Panels = 8,280 W STC

Occupies 43.7 m2 (470 sq ft) producing 7,613 W PTC; NEC 690.8 OCPD floor is 14.84 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.0 * (1 + (-0.337/100) * (-10 - 25)) = 53.66 V | OCPD = 1.56 * 9.51 = 14.84 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM360M-72H-V: Voc=48.0 V, beta_Voc=-0.337%/C, Isc=9.51 A, STC=360.0 W, Area=1.9 m2.

**Result:** 11 panels max on 600 V (590.3 V); 23 panels for 8 kW (470 sq ft).

## What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM360M-72H-V?

Official CEC datasheet figures for Jinko Solar Co Ltd JKM360M-72H-V (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM360M-72H-V.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 331.0 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 39.5 V / 9.12 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.337 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.95% (1.9 m2) | Array roof footprint density |
| **Cell Count & Technology** | 144 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jinko Solar Co Ltd JKM360M-72H-V Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Jinko Solar Co Ltd JKM360M-72H-V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.12 kW | 348 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 23 | 8.28 kW | 470 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 28 | 10.08 kW | 573 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?

Consolidated Jinko Solar Co Ltd wattage variants sharing the Jinko Solar Co Ltd JKM360M-72H-V mechanical and cell layout.

Sibling CEC listings grouped into the Jinko Solar Co Ltd JKM360M-72H-V wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Jinko Solar Co Ltd JKM350M-72H-V** | 350.0 W | 321.5 W | 47.5 V | 39.1 V | 18.42% |
| **Jinko Solar Co Ltd JKM355M-72H-V** | 355.0 W | 326.2 W | 47.8 V | 39.3 V | 18.68% |
| **Jinko Solar Co Ltd JKM360M-72H-V** | 360.0 W | 331.0 W | 48.0 V | 39.5 V | 18.95% |
| **Jinko Solar Co Ltd JKM365M-72H-V** | 365.0 W | 335.7 W | 48.2 V | 39.7 V | 19.21% |
| **Jinko Solar Co Ltd JKM370M-72H-V** | 370.0 W | 340.4 W | 48.5 V | 39.9 V | 19.47% |

## How Many Jinko Solar Co Ltd JKM360M-72H-V Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Jinko Solar Co Ltd JKM360M-72H-V (53.66 V at 14 F).

Computed from Voc=48.0V and beta_Voc=-0.337%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.28 V | 10 panels | 552.8 V | 18 panels |
| **-10 C (14 F)** | 53.66 V | 11 panels | 590.3 V | 18 panels |
| **0 C (32 F)** | 52.04 V | 11 panels | 572.4 V | 19 panels |
| **25 C (77 F STC)** | 48.0 V | 12 panels | 576.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM360M-72H-V?

Competing CEC solar panels closest to Jinko Solar Co Ltd JKM360M-72H-V in nameplate wattage and Voc, starting with Advance Power API-M360.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-M360**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m360/) Advance Power | 360.0 W | Tie (0 W) | 47.56 V | 18.56% | 91.7% |
| [**Auxin Solar AXN6M612T360**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t360/) Auxin Solar | 360.0 W | Tie (0 W) | 47.56 V | 18.55% | 91.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-360**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-360/) Boviet Solar Technology Co Ltd | 360.0 W | Tie (0 W) | 47.5 V | 18.56% | 92.3% |
| [**Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development-co-ltd/anhui-rinengzhongtian-semiconductor-development-co-ltd-qjm360-72/) Anhui Rinengzhongtian Semiconductor Development Co Ltd | 360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM360M-72H-V?

Evaluate Jinko Solar Co Ltd JKM360M-72H-V (360.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM360M-72H-V reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (470 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM360M-72H-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jinko Solar Co Ltd JKM360M-72H-V 8 kW Residential Fit

Needs 23 modules (470 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Advance Power API-M360.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 331.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM360M-72H-V by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM360M-72H-V?

Multiplying Jinko Solar Co Ltd JKM360M-72H-V's 9.51 A short-circuit current by 1.56 equals 14.84 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Jinko Solar Co Ltd JKM360M-72H-V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.66 V cold Voc at 14 F and handles 9.51 A Isc; string inverters cap Jinko Solar Co Ltd JKM360M-72H-V at 11 panels on 600 V.

### Is Jinko Solar Co Ltd JKM360M-72H-V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM360M-72H-V rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jinko Solar Co Ltd equipment, Advance Power API-M360 specs, utility payback rates, and NEC string calculators alongside Jinko Solar Co Ltd JKM360M-72H-V.

[All Jinko Solar Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jinko Solar Co Ltd

- [All Jinko Solar Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/jinko-solar-co-ltd/)
- [Jinko Solar Co Ltd JKM650N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm650n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM635N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm635n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM610N-66HL4M-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDV](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdv/)
- [Jinko Solar Co Ltd JKM605N-72HL4-BDX](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm605n-72hl4-bdx/)