# Jiangyin Hareon Power HR-240P-AC/BbP — CEC Solar Module Specifications

Manufacturer: [**Jiangyin Hareon Power**](https://epri-peac.com/solar-equipment/brands/jiangyin-hareon-power/) Registry: **CEC Verified Engineering Specification**

Jiangyin Hareon Power HR-240P-AC/BbP is a 240.0 W STC (213.1 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.79% efficiency, 37.25 V Voc at 25 C, and 41.68 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 213.1 W

- **Voc @ 25C** : 37.25 V

- **Efficiency** : 14.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jiangyin Hareon Power HR-240P-AC/BbP Compare Against Peer CEC Listings?

How Jiangyin Hareon Power Jiangyin Hareon Power HR-240P-AC/BbP handles rooftop heat (213.1 W PTC), 8 kW sizing, and cold winter string voltage.

Jiangyin Hareon Power builds the Jiangyin Hareon Power HR-240P-AC/BbP (Multi-c-Si) as a compact residential or specialty off-grid module delivering 147.9 W/m2 (5.12 percentage points below 19.91% CEC median). Compared against CSI Solar Co Ltd CS6P-240M (240.0 W), this model holds typical 88.8% PTC-to-STC thermal output (213.1 W real-world rating). Lower 37.25 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.23 A overcurrent floor served by a 15 A breaker.

## Where Does Jiangyin Hareon Power HR-240P-AC/BbP Fall Across Listed CEC Models?

Where Jiangyin Hareon Power HR-240P-AC/BbP (240.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Jiangyin Hareon Power HR-240P-AC/BbP?

Percentile placement of Jiangyin Hareon Power HR-240P-AC/BbP across power density (147.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Jiangyin Hareon Power HR-240P-AC/BbP?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jiangyin Hareon Power HR-240P-AC/BbP specifications.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,049

### 14.79% Aperture Efficiency

Power density 147.9 W/m2 (5.12 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.68 V at -10 C (583.5 V string) and 42.95 V at -20 C (13 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,245 W PTC; NEC 690.8 OCPD floor is 13.23 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.25 * (1 + (-0.34/100) * (-10 - 25)) = 41.68 V | OCPD = 1.56 * 8.48 = 13.23 A

Inputs from CEC Modules.csv for Jiangyin Hareon Power HR-240P-AC/BbP: Voc=37.25 V, beta_Voc=-0.34%/C, Isc=8.48 A, STC=240.0 W, Area=1.623 m2.

**Result:** 14 panels max on 600 V (583.5 V); 34 panels for 8 kW (594 sq ft).

## What Are the Published CEC Specifications for Jiangyin Hareon Power HR-240P-AC/BbP?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jiangyin Hareon Power HR-240P-AC/BbP.

Official California Energy Commission (NREL SAM) test parameters for Jiangyin Hareon Power HR-240P-AC/BbP.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 213.1 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.67 V / 8.09 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.79% (1.623 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Jiangyin Hareon Power HR-240P-AC/BbP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jiangyin Hareon Power HR-240P-AC/BbP (240.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 437 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 594 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 734 sq ft | $2,523 | $4,266 |

## How Many Jiangyin Hareon Power HR-240P-AC/BbP Modules Fit in a Cold-Weather String?

Maximum series module counts for Jiangyin Hareon Power HR-240P-AC/BbP from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.25V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.95 V | 13 panels | 558.4 V | 23 panels |
| **-10 C (14 F)** | 41.68 V | 14 panels | 583.5 V | 23 panels |
| **0 C (32 F)** | 40.42 V | 14 panels | 565.9 V | 24 panels |
| **25 C (77 F STC)** | 37.25 V | 16 panels | 596.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jiangyin Hareon Power HR-240P-AC/BbP?

Alternative CEC solar modules from competing brands near Jiangyin Hareon Power HR-240P-AC/BbP (240.0 W), including CSI Solar Co Ltd CS6P-240M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6P-240M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-240m/) CSI Solar Co Ltd | 240.0 W | Tie (0 W) | 37.3 V | 15.5% | 90.5% |
| [**CSI Solar Co Ltd CS6P-240MX**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-240mx/) CSI Solar Co Ltd | 240.0 W | Tie (0 W) | 37.3 V | 15.5% | 88.3% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-2-240q/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.3 V | 14.53% | 89.0% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QB**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pa-2-240qb/) Hanwha Qcells (Qidong) Co Ltd | 240.0 W | Tie (0 W) | 37.3 V | 14.53% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jiangyin Hareon Power HR-240P-AC/BbP?

Evaluate Jiangyin Hareon Power HR-240P-AC/BbP (240.0 W STC, 37.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jiangyin Hareon Power HR-240P-AC/BbP reaches 42.95 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Jiangyin Hareon Power HR-240P-AC/BbP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jiangyin Hareon Power HR-240P-AC/BbP 8 kW Residential Fit

Needs 34 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS6P-240M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jiangyin Hareon Power HR-240P-AC/BbP by Jiangyin Hareon Power grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jiangyin Hareon Power HR-240P-AC/BbP?

Multiplying Jiangyin Hareon Power HR-240P-AC/BbP's 8.48 A short-circuit current by 1.56 equals 13.23 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Jiangyin Hareon Power HR-240P-AC/BbP pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.68 V cold Voc at 14 F and handles 8.48 A Isc; string inverters cap Jiangyin Hareon Power HR-240P-AC/BbP at 14 panels on 600 V.

### Is Jiangyin Hareon Power HR-240P-AC/BbP eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jiangyin Hareon Power HR-240P-AC/BbP rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jiangyin Hareon Power equipment, CSI Solar Co Ltd CS6P-240M specs, utility payback rates, and NEC string calculators alongside Jiangyin Hareon Power HR-240P-AC/BbP.

[All Jiangyin Hareon Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jiangyin-hareon-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jiangyin Hareon Power

- [All Jiangyin Hareon Power Specs](https://epri-peac.com/solar-equipment/brands/jiangyin-hareon-power/)
- [Jiangyin Hareon Power HR-240P-AC/Bb](https://epri-peac.com/solar-equipment/modules/jiangyin-hareon-power/jiangyin-hareon-power-hr-240p-ac-bb/)
- [Jiangyin Hareon Power HR-170W/24V](https://epri-peac.com/solar-equipment/modules/jiangyin-hareon-power/jiangyin-hareon-power-hr-170w-24v/)