title: "Jackery Inc JS-45A Specs (45.0W, 5.54V Voc)"
url: https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-45a/
description: "CEC datasheet for Jackery Inc JS-45A: 45.0W STC, 5.54V Voc, 178-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Jackery Inc JS-45A — CEC Solar Module Specifications

Manufacturer: [**Jackery Inc**](https://epri-peac.com/solar-equipment/brands/jackery-inc/) Registry: **CEC Verified Engineering Specification**

Jackery Inc JS-45A is a 45.0 W STC (41.6 W PTC) Mono-c-Si solar module ranking #21,667 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 15.36% efficiency, 5.54 V Voc at 25 C, and 6.04 V cold Voc at -10 C (99 panels max per 600 V string).

- **STC Wattage** : 45.0 W

- **PTC Wattage** : 41.6 W

- **Voc @ 25C** : 5.54 V

- **Efficiency** : 15.36%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jackery Inc JS-45A Compare Against Peer CEC Listings?

How Jackery Inc Jackery Inc JS-45A handles rooftop heat (41.6 W PTC), 8 kW sizing, and cold winter string voltage.

Jackery Inc builds the Jackery Inc JS-45A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 153.6 W/m2 (4.55 percentage points below 19.91% CEC median). Compared against Solar Frame Solutions Inc SFS50S (50.0 W), this model holds strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Lower 5.54 V string voltage fits 99 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 16.16 A overcurrent floor served by a 20 A breaker.

## Where Does Jackery Inc JS-45A Fall Across Listed CEC Models?

Where Jackery Inc JS-45A (45.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Jackery Inc JS-45A?

Percentile placement of Jackery Inc JS-45A across power density (153.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Jackery Inc JS-45A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jackery Inc JS-45A specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,667 / 21,677

### 45.0 W STC · Higher Than 0.0%

45.0 W STC (-340.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,197

### 15.36% Aperture Efficiency

Power density 153.6 W/m2 (4.55 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

### 99 Panels Max @ -10 C (600 V)

Cold Voc reaches 6.04 V at -10 C (598.0 V string) and 6.19 V at -20 C (96 max).

 8 kW Reference Array

### 178 Panels = 8,010 W STC

Occupies 52.2 m2 (561 sq ft) producing 7,405 W PTC; NEC 690.8 OCPD floor is 16.16 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 5.54 * (1 + (-0.26/100) * (-10 - 25)) = 6.04 V | OCPD = 1.56 * 10.36 = 16.16 A

Inputs from CEC Modules.csv for Jackery Inc JS-45A: Voc=5.54 V, beta_Voc=-0.26%/C, Isc=10.36 A, STC=45.0 W, Area=0.293 m2.

**Result:** 99 panels max on 600 V (598.0 V); 178 panels for 8 kW (561 sq ft).

## What Are the Published CEC Specifications for Jackery Inc JS-45A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jackery Inc JS-45A.

Official California Energy Commission (NREL SAM) test parameters for Jackery Inc JS-45A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 45.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 41.6 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 5.54 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 4.53 V / 9.93 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.26 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.36% (0.293 m2) | Array roof footprint density |
| **Cell Count & Technology** | 8 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jackery Inc JS-45A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jackery Inc JS-45A (45.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 134 | 6.03 kW | 423 sq ft | $1,509 | $2,552 |
| **8 kW Class** | 178 | 8.01 kW | 561 sq ft | $2,005 | $3,390 |
| **10 kW Class** | 223 | 10.04 kW | 703 sq ft | $2,513 | $4,249 |

## How Many Jackery Inc JS-45A Modules Fit in a Cold-Weather String?

Maximum series module counts for Jackery Inc JS-45A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=5.54V and beta_Voc=-0.26%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 6.19 V | 96 panels | 594.2 V | 161 panels |
| **-10 C (14 F)** | 6.04 V | 99 panels | 598.0 V | 165 panels |
| **0 C (32 F)** | 5.9 V | 101 panels | 595.9 V | 169 panels |
| **25 C (77 F STC)** | 5.54 V | 108 panels | 598.3 V | 180 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jackery Inc JS-45A?

Alternative CEC solar modules from competing brands near Jackery Inc JS-45A (45.0 W), including Solar Frame Solutions Inc SFS50S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Solar Frame Solutions Inc SFS50S**](https://epri-peac.com/solar-equipment/modules/solar-frame-solutions-inc/solar-frame-solutions-inc-sfs50s/) Solar Frame Solutions Inc | 50.0 W | +5.0 W | 6.1 V | 13.89% | 91.4% |
| [**Rare Manufacturing IW-40-B12345YZZ**](https://epri-peac.com/solar-equipment/modules/rare-manufacturing/rare-manufacturing-iw-40-b12345yzz/) Rare Manufacturing | 40.0 W | -5.0 W | 9.26 V | 11.74% | 64.2% |
| [**GAF Energy LLC 294000328**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-294000328/) GAF Energy LLC | 45.0 W | Tie (0 W) | 10.89 V | 6.43% | 85.8% |
| [**GAF Energy LLC TLS-1**](https://epri-peac.com/solar-equipment/modules/gaf-energy-llc/gaf-energy-llc-tls-1/) GAF Energy LLC | 46.0 W | +1.0 W | 10.9 V | 6.57% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jackery Inc JS-45A?

Evaluate Jackery Inc JS-45A (45.0 W STC, 5.54 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jackery Inc JS-45A reaches 6.19 V per panel—exceeding 96 panels in series voids 600 V inverter warranties.
- Footprint constraint: 178 panels for an 8 kW build require 561 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 178 panels (561 sq ft).
- 2026 tax credit baseline: cash residential installs of Jackery Inc JS-45A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jackery Inc JS-45A 8 kW Residential Fit

Needs 178 modules (561 sq ft) with a 20 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 99 panels (-10 C) or 96 panels (-20 C), or compare Solar Frame Solutions Inc SFS50S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 41.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jackery Inc JS-45A by Jackery Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jackery Inc JS-45A?

Multiplying Jackery Inc JS-45A's 10.36 A short-circuit current by 1.56 equals 16.16 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Jackery Inc JS-45A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 6.04 V cold Voc at 14 F and handles 10.36 A Isc; string inverters cap Jackery Inc JS-45A at 99 panels on 600 V.

### Is Jackery Inc JS-45A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jackery Inc JS-45A rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jackery Inc equipment, Solar Frame Solutions Inc SFS50S specs, utility payback rates, and NEC string calculators alongside Jackery Inc JS-45A.

[All Jackery Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jackery-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jackery Inc

- [All Jackery Inc Specs](https://epri-peac.com/solar-equipment/brands/jackery-inc/)
- [Jackery Inc JS-42A](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-42a/)
- [Jackery Inc JS-38A](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-38a/)
- [Jackery Inc JS-36A](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-36a/)