# Jackery Inc JS-36A — CEC Solar Module Specifications

Manufacturer: [**Jackery Inc**](https://epri-peac.com/solar-equipment/brands/jackery-inc/) Registry: **CEC Verified Engineering Specification**

Jackery Inc JS-36A is a 36.0 W STC (32.7 W PTC) Mono-c-Si solar module ranking #21,672 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 12.29% efficiency, 5.54 V Voc at 25 C, and 6.14 V cold Voc at -10 C (97 panels max per 600 V string).

- **STC Wattage** : 36.0 W

- **PTC Wattage** : 32.7 W

- **Voc @ 25C** : 5.54 V

- **Efficiency** : 12.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Jackery Inc JS-36A Compare Against Peer CEC Listings?

How Jackery Inc Jackery Inc JS-36A handles rooftop heat (32.7 W PTC), 8 kW sizing, and cold winter string voltage.

Jackery Inc builds the Jackery Inc JS-36A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 122.9 W/m2 (7.62 percentage points below 19.91% CEC median). Compared against Tesla Inc SR25S3 (25.0 W), this model holds typical 90.8% PTC-to-STC thermal output (32.7 W real-world rating). Lower 5.54 V string voltage fits 97 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.81 A overcurrent floor served by a 15 A breaker.

## Where Does Jackery Inc JS-36A Fall Across Listed CEC Models?

Where Jackery Inc JS-36A (36.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Jackery Inc JS-36A?

Percentile placement of Jackery Inc JS-36A across power density (122.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Jackery Inc JS-36A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jackery Inc JS-36A specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,672 / 21,677

### 36.0 W STC · Higher Than 0.0%

36.0 W STC (-349.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,549

### 12.29% Aperture Efficiency

Power density 122.9 W/m2 (7.62 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

### 97 Panels Max @ -10 C (600 V)

Cold Voc reaches 6.14 V at -10 C (595.6 V string) and 6.32 V at -20 C (94 max).

 8 kW Reference Array

### 223 Panels = 8,028 W STC

Occupies 65.3 m2 (703 sq ft) producing 7,292 W PTC; NEC 690.8 OCPD floor is 13.81 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 5.54 * (1 + (-0.311/100) * (-10 - 25)) = 6.14 V | OCPD = 1.56 * 8.85 = 13.81 A

Inputs from CEC Modules.csv for Jackery Inc JS-36A: Voc=5.54 V, beta_Voc=-0.311%/C, Isc=8.85 A, STC=36.0 W, Area=0.293 m2.

**Result:** 97 panels max on 600 V (595.6 V); 223 panels for 8 kW (703 sq ft).

## What Are the Published CEC Specifications for Jackery Inc JS-36A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jackery Inc JS-36A.

Official California Energy Commission (NREL SAM) test parameters for Jackery Inc JS-36A.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 36.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 32.7 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 5.54 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 4.53 V / 7.95 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.311 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.29% (0.293 m2) | Array roof footprint density |
| **Cell Count & Technology** | 8 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Jackery Inc JS-36A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jackery Inc JS-36A (36.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 167 | 6.01 kW | 527 sq ft | $1,504 | $2,544 |
| **8 kW Class** | 223 | 8.03 kW | 703 sq ft | $2,010 | $3,398 |
| **10 kW Class** | 278 | 10.01 kW | 877 sq ft | $2,505 | $4,236 |

## How Many Jackery Inc JS-36A Modules Fit in a Cold-Weather String?

Maximum series module counts for Jackery Inc JS-36A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=5.54V and beta_Voc=-0.311%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 6.32 V | 94 panels | 594.1 V | 158 panels |
| **-10 C (14 F)** | 6.14 V | 97 panels | 595.6 V | 162 panels |
| **0 C (32 F)** | 5.97 V | 100 panels | 597.0 V | 167 panels |
| **25 C (77 F STC)** | 5.54 V | 108 panels | 598.3 V | 180 panels |

## Which Cross-Brand Solar Modules Compare Closest to Jackery Inc JS-36A?

Alternative CEC solar modules from competing brands near Jackery Inc JS-36A (36.0 W), including Tesla Inc SR25S3. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Tesla Inc SR25S3**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr25s3/) Tesla Inc | 25.0 W | -11.0 W | 4.3 V | 10.58% | 89.2% |
| [**Tesla Inc SR25T3**](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr25t3/) Tesla Inc | 25.0 W | -11.0 W | 4.3 V | 10.56% | 87.6% |
| [**Solar Frame Solutions Inc SFS50S**](https://epri-peac.com/solar-equipment/modules/solar-frame-solutions-inc/solar-frame-solutions-inc-sfs50s/) Solar Frame Solutions Inc | 50.0 W | +14.0 W | 6.1 V | 13.89% | 91.4% |
| [**Rare Manufacturing IW-40-B12345YZZ**](https://epri-peac.com/solar-equipment/modules/rare-manufacturing/rare-manufacturing-iw-40-b12345yzz/) Rare Manufacturing | 40.0 W | +4.0 W | 9.26 V | 11.74% | 64.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Jackery Inc JS-36A?

Evaluate Jackery Inc JS-36A (36.0 W STC, 5.54 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Jackery Inc JS-36A reaches 6.32 V per panel—exceeding 94 panels in series voids 600 V inverter warranties.
- Footprint constraint: 223 panels for an 8 kW build require 703 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 223 panels (703 sq ft).
- 2026 tax credit baseline: cash residential installs of Jackery Inc JS-36A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Jackery Inc JS-36A 8 kW Residential Fit

Needs 223 modules (703 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 97 panels (-10 C) or 94 panels (-20 C), or compare Tesla Inc SR25S3.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 32.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jackery Inc JS-36A by Jackery Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Jackery Inc JS-36A?

Multiplying Jackery Inc JS-36A's 8.85 A short-circuit current by 1.56 equals 13.81 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Jackery Inc JS-36A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 6.14 V cold Voc at 14 F and handles 8.85 A Isc; string inverters cap Jackery Inc JS-36A at 97 panels on 600 V.

### Is Jackery Inc JS-36A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jackery Inc JS-36A rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

## Related Pages

Compare Jackery Inc equipment, Tesla Inc SR25S3 specs, utility payback rates, and NEC string calculators alongside Jackery Inc JS-36A.

[All Jackery Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/jackery-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Jackery Inc

- [All Jackery Inc Specs](https://epri-peac.com/solar-equipment/brands/jackery-inc/)
- [Jackery Inc JS-45A](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-45a/)
- [Jackery Inc JS-42A](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-42a/)
- [Jackery Inc JS-38A](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-38a/)