---
title: "JA Solar JAP72S01-335/SC Specs (335.0W, 46.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap72s01-335-sc/
description: "CEC datasheet for JA Solar JAP72S01-335/SC: 335.0W STC, 46.7V Voc, 24-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP72S01-335/SC — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP72S01-335/SC is a 335.0 W STC (309.0 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.78% efficiency, 46.7 V Voc at 25 C, and 51.54 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 335.0 W

- **PTC Wattage** : 309.0 W

- **Voc @ 25C** : 46.7 V

- **Efficiency** : 17.78%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP72S01-335/SC Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP72S01-335/SC handles rooftop heat (309.0 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAP72S01-335/SC (Multi-c-Si) as a compact residential or specialty off-grid module delivering 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). Compared against Centrosolar America EM72 335BW (335.0 W), this model holds strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Mid-range 46.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.59 A overcurrent floor served by a 15 A breaker.

## Where Does JA Solar JAP72S01-335/SC Fall Across Listed CEC Models?

Where JA Solar JAP72S01-335/SC (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAP72S01-335/SC?

Percentile placement of JA Solar JAP72S01-335/SC across power density (177.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAP72S01-335/SC?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP72S01-335/SC specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #13,844 / 21,677

### 335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,390

### 17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.54 V at -10 C (566.9 V string) and 52.92 V at -20 C (11 max).

 8 kW Reference Array

### 24 Panels = 8,040 W STC

Occupies 45.2 m2 (487 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 14.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.7 * (1 + (-0.296/100) * (-10 - 25)) = 51.54 V | OCPD = 1.56 * 9.35 = 14.59 A

Inputs from CEC Modules.csv for JA Solar JAP72S01-335/SC: Voc=46.7 V, beta_Voc=-0.296%/C, Isc=9.35 A, STC=335.0 W, Area=1.884 m2.

**Result:** 11 panels max on 600 V (566.9 V); 24 panels for 8 kW (487 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP72S01-335/SC?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP72S01-335/SC.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP72S01-335/SC.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 309.0 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 46.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.83 V / 8.87 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.296 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.78% (1.884 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP72S01-335/SC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP72S01-335/SC (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 18 | 6.03 kW | 365 sq ft | $1,509 | $2,552 |
| **8 kW Class** | 24 | 8.04 kW | 487 sq ft | $2,012 | $3,403 |
| **10 kW Class** | 30 | 10.05 kW | 608 sq ft | $2,515 | $4,253 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP72S01-335/SC architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the JA Solar JAP72S01-335/SC wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP72S01-325/SC** | 325.0 W | 300.1 W | 46.38 V | 37.39 V | 17.29% |
| **JA Solar JAP72S01-330/SC** | 330.0 W | 304.2 W | 46.4 V | 37.65 V | 17.52% |
| **JA Solar JAP72S01-335/SC** | 335.0 W | 309.0 W | 46.7 V | 37.83 V | 17.78% |
| **JA Solar JAP72S01-340/SC** | 340.0 W | 313.7 W | 47.0 V | 38.02 V | 18.05% |

## How Many JA Solar JAP72S01-335/SC Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP72S01-335/SC from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.7V and beta_Voc=-0.296%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.92 V | 11 panels | 582.1 V | 18 panels |
| **-10 C (14 F)** | 51.54 V | 11 panels | 566.9 V | 19 panels |
| **0 C (32 F)** | 50.16 V | 11 panels | 551.8 V | 19 panels |
| **25 C (77 F STC)** | 46.7 V | 12 panels | 560.4 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP72S01-335/SC?

Alternative CEC solar modules from competing brands near JA Solar JAP72S01-335/SC (335.0 W), including Centrosolar America EM72 335BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America EM72 335BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335bw/) Centrosolar America | 335.0 W | Tie (0 W) | 46.75 V | 17.42% | 91.4% |
| [**Centrosolar America EM72 335SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-335sw/) Centrosolar America | 335.0 W | Tie (0 W) | 46.75 V | 17.42% | 91.4% |
| [**Bluesun Solar Energy Tech CoLtd BSM335P-72**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-energy-tech-coltd/bluesun-solar-energy-tech-coltd-bsm335p-72/) Bluesun Solar Energy Tech CoLtd | 335.0 W | Tie (0 W) | 46.76 V | 17.29% | 91.4% |
| [**AXITEC AC-335P/72X**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-335p-72x/) AXITEC | 335.0 W | Tie (0 W) | 46.45 V | 17.36% | 90.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP72S01-335/SC?

Evaluate JA Solar JAP72S01-335/SC (335.0 W STC, 46.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP72S01-335/SC reaches 52.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 487 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (487 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP72S01-335/SC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP72S01-335/SC 8 kW Residential Fit

Needs 24 modules (487 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EM72 335BW.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP72S01-335/SC by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAP72S01-335/SC?

Multiplying JA Solar JAP72S01-335/SC's 9.35 A short-circuit current by 1.56 equals 14.59 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can JA Solar JAP72S01-335/SC pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.54 V cold Voc at 14 F and handles 9.35 A Isc; string inverters cap JA Solar JAP72S01-335/SC at 11 panels on 600 V.

### Is JA Solar JAP72S01-335/SC eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP72S01-335/SC rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, Centrosolar America EM72 335BW specs, utility payback rates, and NEC string calculators alongside JA Solar JAP72S01-335/SC.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)
