title: "JA Solar JAP6(BK)-72-310/MP Specs (310.0W, 45.81V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-bk-72-310-mp/
description: "CEC datasheet for JA Solar JAP6(BK)-72-310/MP: 310.0W STC, 45.81V Voc, 26-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6(BK)-72-310/MP — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6(BK)-72-310/MP is a 310.0 W STC (274.4 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.99% efficiency, 45.81 V Voc at 25 C, and 51.33 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 274.4 W

- **Voc @ 25C** : 45.81 V

- **Efficiency** : 15.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6(BK)-72-310/MP Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6(BK)-72-310/MP (Multi-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAP6(BK)-72-310/MP need 20 panels for 6 kW or 26 panels (542 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). Under NEC 690.7(A), beta_Voc (-0.344%/C) pushes open-circuit voltage to 51.33 V at 14 F and 52.9 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAP6(BK)-72-310/MP Fall Across Listed CEC Models?

Comparison of JA Solar JAP6(BK)-72-310/MP (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define JA Solar JAP6(BK)-72-310/MP?

Relative ranking of JA Solar JAP6(BK)-72-310/MP across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for JA Solar JAP6(BK)-72-310/MP?

Summary of JA Solar JAP6(BK)-72-310/MP output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,133

### 15.99% Aperture Efficiency

Power density 160.0 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.33 V at -10 C (564.6 V string) and 52.9 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.4 m2 (542 sq ft) producing 7,134 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.81 * (1 + (-0.344/100) * (-10 - 25)) = 51.33 V | OCPD = 1.56 * 8.8 = 13.73 A

Inputs from CEC Modules.csv for JA Solar JAP6(BK)-72-310/MP: Voc=45.81 V, beta_Voc=-0.344%/C, Isc=8.8 A, STC=310.0 W, Area=1.938 m2.

**Result:** 11 panels max on 600 V (564.6 V); 26 panels for 8 kW (542 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6(BK)-72-310/MP?

Complete CEC test sheet for JA Solar JAP6(BK)-72-310/MP including Isc (8.8 A), Voc (45.81 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6(BK)-72-310/MP.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 274.4 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.58 V / 8.25 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.344 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.99% (1.938 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6(BK)-72-310/MP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6(BK)-72-310/MP.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 417 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 688 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6(BK)-72-310/MP series guide.

Sibling CEC listings grouped into the JA Solar JAP6(BK)-72-310/MP wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6(BK)-72-300/MP** | 300.0 W | 265.3 W | 45.67 V | 36.9 V | 15.48% |
| **JA Solar JAP6(BK)-72-305/MP** | 305.0 W | 269.9 W | 45.74 V | 37.24 V | 15.73% |
| **JA Solar JAP6(BK)-72-310/MP** | 310.0 W | 274.4 W | 45.81 V | 37.58 V | 15.99% |
| **JA Solar JAP6(BK)-72-315/MP** | 315.0 W | 279.0 W | 45.9 V | 37.91 V | 16.25% |

## How Many JA Solar JAP6(BK)-72-310/MP Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6(BK)-72-310/MP (45.81 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.81V and beta_Voc=-0.344%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.9 V | 11 panels | 581.9 V | 18 panels |
| **-10 C (14 F)** | 51.33 V | 11 panels | 564.6 V | 19 panels |
| **0 C (32 F)** | 49.75 V | 12 panels | 597.0 V | 20 panels |
| **25 C (77 F STC)** | 45.81 V | 13 panels | 595.5 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-72-310/MP?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612P-310 (310.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612P-310**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612p-310/) Boviet Solar Technology Co Ltd | 310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| [**Centrosolar America CP72 310-C1**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-cp72-310-c1/) Centrosolar America | 310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| [**BYD Company Limited BYD 310P6C-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-310p6c-36/) BYD Company Limited | 310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.2% |
| [**BYD Company Limited BYD310P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd310p6k-36/) BYD Company Limited | 310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-72-310/MP?

Evaluate JA Solar JAP6(BK)-72-310/MP (310.0 W STC, 45.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-72-310/MP reaches 52.9 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-72-310/MP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6(BK)-72-310/MP 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6(BK)-72-310/MP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAP6(BK)-72-310/MP PTC wattage (274.4 W) lower than STC (310.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 274.4 W PTC (88.5% retention) across JA Solar JAP6(BK)-72-310/MP's 1.938 m2 aperture.

### Who should skip JA Solar JAP6(BK)-72-310/MP on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 JA Solar JAP6(BK)-72-310/MP panels (542 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612P-310.

### What is the 1,000 V commercial string limit for JA Solar JAP6(BK)-72-310/MP?

On 1,000 V commercial inverters at -10 C (51.33 V cold Voc), JA Solar JAP6(BK)-72-310/MP fits up to 19 panels per series string.

## Related Pages

Compare JA Solar equipment, Boviet Solar Technology Co Ltd BVM6612P-310 specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6(BK)-72-310/MP.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)