title: "JA Solar JAP6(BK)-60-250 Specs (250.0W, 37.85V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-bk-60-250/
description: "CEC datasheet for JA Solar JAP6(BK)-60-250: 250.0W STC, 37.85V Voc, 32-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6(BK)-60-250 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6(BK)-60-250 is a 250.0 W STC (222.9 W PTC) Multi-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.29% efficiency, 37.85 V Voc at 25 C, and 42.67 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 250.0 W

- **PTC Wattage** : 222.9 W

- **Voc @ 25C** : 37.85 V

- **Efficiency** : 15.29%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6(BK)-60-250 Compare Against Peer CEC Listings?

Engineering position of JA Solar JAP6(BK)-60-250 (250.0 W STC) vs. Changzhou Nesl Solartech DJ-250DA/C-ST15 across 1,407 CEC Multi-c-Si solar modules.

Ranking #19,686 across 21,677 CEC solar panels (below all-CEC median; higher than 8.0% of peers), JA Solar JAP6(BK)-60-250 operates as a compact residential or specialty off-grid module sitting 28.8 W below the 278.8 W Multi-c-Si median. Lower 37.85 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 89.2% PTC-to-STC thermal output (222.9 W real-world rating), 32 panels occupy 563 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAP6(BK)-60-250 Fall Across Listed CEC Models?

Plots JA Solar JAP6(BK)-60-250 at 250.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAP6(BK)-60-250?

Benchmarks JA Solar JAP6(BK)-60-250 on STC wattage, thermal PTC/STC retention, and 15.29 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAP6(BK)-60-250?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6(BK)-60-250 by JA Solar.

Rank #19,686 / 21,677

### 250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,272

### 15.29% Aperture Efficiency

Power density 152.9 W/m2 (4.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.67 V at -10 C (597.4 V string) and 44.05 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,000 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,133 W PTC; NEC 690.8 OCPD floor is 13.49 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.85 * (1 + (-0.364/100) * (-10 - 25)) = 42.67 V | OCPD = 1.56 * 8.65 = 13.49 A

Inputs from CEC Modules.csv for JA Solar JAP6(BK)-60-250: Voc=37.85 V, beta_Voc=-0.364%/C, Isc=8.65 A, STC=250.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (597.4 V); 32 panels for 8 kW (563 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6(BK)-60-250?

Laboratory test ratings recorded for JA Solar JAP6(BK)-60-250 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6(BK)-60-250.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 250.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 222.9 W (89.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.12 V / 8.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.364 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.29% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6(BK)-60-250 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (563 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6(BK)-60-250.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.0 kW | 422 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 32 | 8.0 kW | 563 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 40 | 10.0 kW | 704 sq ft | $2,503 | $4,232 |

## How Many JA Solar JAP6(BK)-60-250 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAP6(BK)-60-250 (beta_Voc -0.364%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.85V and beta_Voc=-0.364%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.05 V | 13 panels | 572.6 V | 22 panels |
| **-10 C (14 F)** | 42.67 V | 14 panels | 597.4 V | 23 panels |
| **0 C (32 F)** | 41.29 V | 14 panels | 578.1 V | 24 panels |
| **25 C (77 F STC)** | 37.85 V | 15 panels | 567.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-60-250?

Closest cross-brand CEC competitors to JA Solar JAP6(BK)-60-250 matched near 250.0 W STC and 37.85 V Voc, led by Changzhou Nesl Solartech DJ-250DA/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Changzhou Nesl Solartech DJ-250DA/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-250da-c-st15/) Changzhou Nesl Solartech | 250.0 W | Tie (0 W) | 38.07 V | 15.3% | 90.4% |
| [**Boviet Solar Technology Co Ltd BVM6610P-250**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610p-250/) Boviet Solar Technology Co Ltd | 250.0 W | Tie (0 W) | 37.5 V | 15.37% | 90.2% |
| [**Anji Technology AJP-M660-250**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-250/) Anji Technology | 250.0 W | Tie (0 W) | 37.32 V | 15.4% | 89.0% |
| [**Eoplly New Energy Technology EP156MB/60-250S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-250s-ac/) Eoplly New Energy Technology | 250.0 W | Tie (0 W) | 37.26 V | 15.45% | 89.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-60-250?

Evaluate JA Solar JAP6(BK)-60-250 (250.0 W STC, 37.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-60-250 reaches 44.05 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (563 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-60-250 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6(BK)-60-250 8 kW Residential Fit

Needs 32 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-250DA/C-ST15.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 222.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6(BK)-60-250 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAP6(BK)-60-250 panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6(BK)-60-250 cold Voc rises from 37.85 V to 42.67 V (beta_Voc -0.364%/C), capping a 600 V string at 14 panels (597.4 V).

### How much roof area does an 8 kW array of JA Solar JAP6(BK)-60-250 need?

An 8 kW DC system uses 32 JA Solar JAP6(BK)-60-250 modules (8,000 W STC / 7,133 W PTC), covering roughly 563 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does JA Solar JAP6(BK)-60-250 compare against Changzhou Nesl Solartech DJ-250DA/C-ST15?

JA Solar JAP6(BK)-60-250 outputs 250.0 W STC (37.85 V Voc, rank #19,686 of 21,677), while Changzhou Nesl Solartech DJ-250DA/C-ST15 delivers 250.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, Changzhou Nesl Solartech DJ-250DA/C-ST15 specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6(BK)-60-250.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)