title: "JA Solar JAP6-72-330/4BB/RE Specs (330.0W, 47.48V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-72-330-4bb-re/
description: "CEC datasheet for JA Solar JAP6-72-330/4BB/RE: 330.0W STC, 47.48V Voc, 25-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-72-330/4BB/RE — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-72-330/4BB/RE is a 330.0 W STC (302.5 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.02% efficiency, 47.48 V Voc at 25 C, and 52.48 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 330.0 W

- **PTC Wattage** : 302.5 W

- **Voc @ 25C** : 47.48 V

- **Efficiency** : 17.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-72-330/4BB/RE Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-72-330/4BB/RE handles rooftop heat (302.5 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAP6-72-330/4BB/RE (Multi-c-Si) as a compact residential or specialty off-grid module delivering 170.3 W/m2 (2.89 percentage points below 19.91% CEC median). Compared against Centrosolar America DM72 330 (330.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Mid-range 47.48 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.62 A overcurrent floor served by a 15 A breaker.

## Where Does JA Solar JAP6-72-330/4BB/RE Fall Across Listed CEC Models?

Where JA Solar JAP6-72-330/4BB/RE (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAP6-72-330/4BB/RE?

Percentile placement of JA Solar JAP6-72-330/4BB/RE across power density (170.3 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAP6-72-330/4BB/RE?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-72-330/4BB/RE specifications.

Rank #14,165 / 21,677

### 330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,417

### 17.02% Aperture Efficiency

Power density 170.3 W/m2 (2.89 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.48 V at -10 C (577.3 V string) and 53.91 V at -20 C (11 max).

 8 kW Reference Array

### 25 Panels = 8,250 W STC

Occupies 48.4 m2 (522 sq ft) producing 7,562 W PTC; NEC 690.8 OCPD floor is 14.62 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.48 * (1 + (-0.301/100) * (-10 - 25)) = 52.48 V | OCPD = 1.56 * 9.37 = 14.62 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-330/4BB/RE: Voc=47.48 V, beta_Voc=-0.301%/C, Isc=9.37 A, STC=330.0 W, Area=1.938 m2.

**Result:** 11 panels max on 600 V (577.3 V); 25 panels for 8 kW (522 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-72-330/4BB/RE?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-72-330/4BB/RE.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-330/4BB/RE.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 302.5 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.48 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.05 V / 8.67 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.301 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.02% (1.938 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-72-330/4BB/RE Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-72-330/4BB/RE (330.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 19 | 6.27 kW | 396 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-72-330/4BB/RE architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the JA Solar JAP6-72-330/4BB/RE wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-72-325/4BB/RE** | 325.0 W | 297.8 W | 46.98 V | 37.61 V | 16.77% |
| **JA Solar JAP6-72-330/4BB/RE** | 330.0 W | 302.5 W | 47.48 V | 38.05 V | 17.02% |
| **JA Solar JAP6-72-335/4BB/RE** | 335.0 W | 307.3 W | 47.98 V | 38.49 V | 17.28% |

## How Many JA Solar JAP6-72-330/4BB/RE Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-72-330/4BB/RE from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.48V and beta_Voc=-0.301%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.91 V | 11 panels | 593.0 V | 18 panels |
| **-10 C (14 F)** | 52.48 V | 11 panels | 577.3 V | 19 panels |
| **0 C (32 F)** | 51.05 V | 11 panels | 561.5 V | 19 panels |
| **25 C (77 F STC)** | 47.48 V | 12 panels | 569.8 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-330/4BB/RE?

Alternative CEC solar modules from competing brands near JA Solar JAP6-72-330/4BB/RE (330.0 W), including Centrosolar America DM72 330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM72 330**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-330/) Centrosolar America | 330.0 W | Tie (0 W) | 46.9 V | 16.97% | 90.9% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6p-330w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| [**Centrosolar America EP72 330BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep72-330bw/) Centrosolar America | 330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |
| [**Centrosolar America EP72 330SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep72-330sw/) Centrosolar America | 330.0 W | Tie (0 W) | 46.65 V | 17.16% | 91.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-330/4BB/RE?

Evaluate JA Solar JAP6-72-330/4BB/RE (330.0 W STC, 47.48 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-330/4BB/RE reaches 53.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-330/4BB/RE carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-72-330/4BB/RE 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 330.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 302.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-330/4BB/RE by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-72-330/4BB/RE?

Multiplying JA Solar JAP6-72-330/4BB/RE's 9.37 A short-circuit current by 1.56 equals 14.62 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can JA Solar JAP6-72-330/4BB/RE pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.48 V cold Voc at 14 F and handles 9.37 A Isc; string inverters cap JA Solar JAP6-72-330/4BB/RE at 11 panels on 600 V.

### Is JA Solar JAP6-72-330/4BB/RE eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-72-330/4BB/RE rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, Centrosolar America DM72 330 specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-72-330/4BB/RE.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)