title: "JA Solar JAP6-72-330/3BB Specs (330.0W, 46.05V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-72-330-3bb/
description: "CEC datasheet for JA Solar JAP6-72-330/3BB: 330.0W STC, 46.05V Voc, 25-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-72-330/3BB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-72-330/3BB is a 330.0 W STC (298.5 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.02% efficiency, 46.05 V Voc at 25 C, and 51.05 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 330.0 W

- **PTC Wattage** : 298.5 W

- **Voc @ 25C** : 46.05 V

- **Efficiency** : 17.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-72-330/3BB Compare Against Peer CEC Listings?

Engineering position of JA Solar JAP6-72-330/3BB (330.0 W STC) vs. Advance Power API-P330 across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, JA Solar JAP6-72-330/3BB pairs typical 90.5% PTC-to-STC thermal output (298.5 W real-world rating) with 46.05 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,462 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Advance Power API-P330 offers a 330.0 W alternative.

## Where Does JA Solar JAP6-72-330/3BB Fall Across Listed CEC Models?

Plots JA Solar JAP6-72-330/3BB at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAP6-72-330/3BB?

Benchmarks JA Solar JAP6-72-330/3BB on STC wattage, thermal PTC/STC retention, and 17.02 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAP6-72-330/3BB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6-72-330/3BB by JA Solar.

Rank #14,165 / 21,677

### 330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,417

### 17.02% Aperture Efficiency

Power density 170.3 W/m2 (2.89 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.05 V at -10 C (561.5 V string) and 52.47 V at -20 C (11 max).

 8 kW Reference Array

### 25 Panels = 8,250 W STC

Occupies 48.4 m2 (522 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 14.18 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.05 * (1 + (-0.31/100) * (-10 - 25)) = 51.05 V | OCPD = 1.56 * 9.09 = 14.18 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-330/3BB: Voc=46.05 V, beta_Voc=-0.31%/C, Isc=9.09 A, STC=330.0 W, Area=1.938 m2.

**Result:** 11 panels max on 600 V (561.5 V); 25 panels for 8 kW (522 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-72-330/3BB?

Laboratory test ratings recorded for JA Solar JAP6-72-330/3BB (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-330/3BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 298.5 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 46.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.11 V / 8.66 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.02% (1.938 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-72-330/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6-72-330/3BB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 19 | 6.27 kW | 396 sq ft | $1,569 | $2,654 |
| **8 kW Class** | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAP6-72-330/3BB under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAP6-72-330/3BB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-72-325/3BB** | 325.0 W | 293.8 W | 45.9 V | 37.84 V | 16.77% |
| **JA Solar JAP6-72-330/3BB** | 330.0 W | 298.5 W | 46.05 V | 38.11 V | 17.02% |

## How Many JA Solar JAP6-72-330/3BB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAP6-72-330/3BB (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.05V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.47 V | 11 panels | 577.2 V | 19 panels |
| **-10 C (14 F)** | 51.05 V | 11 panels | 561.5 V | 19 panels |
| **0 C (32 F)** | 49.62 V | 12 panels | 595.4 V | 20 panels |
| **25 C (77 F STC)** | 46.05 V | 13 panels | 598.6 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-330/3BB?

Closest cross-brand CEC competitors to JA Solar JAP6-72-330/3BB matched near 330.0 W STC and 46.05 V Voc, led by Advance Power API-P330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-P330**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p330/) Advance Power | 330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| [**Auxin Solar AXN6P612T330**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t330/) Auxin Solar | 330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| [**Centrosolar America TM7 330SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm7-330sw/) Centrosolar America | 330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| [**Centrosolar America TM7S 330SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm7s-330sw/) Centrosolar America | 330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-330/3BB?

Evaluate JA Solar JAP6-72-330/3BB (330.0 W STC, 46.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-330/3BB reaches 52.47 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-330/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-72-330/3BB 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P330.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 298.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-330/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-72-330/3BB?

Multiplying JA Solar JAP6-72-330/3BB's 9.09 A short-circuit current by 1.56 equals 14.18 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can JA Solar JAP6-72-330/3BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.05 V cold Voc at 14 F and handles 9.09 A Isc; string inverters cap JA Solar JAP6-72-330/3BB at 11 panels on 600 V.

### Is JA Solar JAP6-72-330/3BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-72-330/3BB rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, Advance Power API-P330 specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-72-330/3BB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)