title: "JA Solar JAP6-72-310 Specs (310.0W, 45.61V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-72-310/
description: "CEC datasheet for JA Solar JAP6-72-310: 310.0W STC, 45.61V Voc, 26-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-72-310 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-72-310 is a 310.0 W STC (281.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.99% efficiency, 45.61 V Voc at 25 C, and 50.86 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 281.0 W

- **Voc @ 25C** : 45.61 V

- **Efficiency** : 15.99%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-72-310 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-72-310 (Multi-c-Si) residential solar systems.

JA Solar JAP6-72-310 delivers 160.0 W/m2 (3.92 percentage points below 19.91% CEC median) and typical 90.6% PTC-to-STC thermal output (281.0 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). At -4 F (-20 C), string voltage climbs to 52.36 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with DEHUI SOLAR POWER INC DH-72P-310W (310.0 W).

## Where Does JA Solar JAP6-72-310 Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-72-310 (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define JA Solar JAP6-72-310?

Relative ranking of JA Solar JAP6-72-310 across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for JA Solar JAP6-72-310?

Summary of JA Solar JAP6-72-310 output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,133

### 15.99% Aperture Efficiency

Power density 160.0 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.86 V at -10 C (559.5 V string) and 52.36 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.4 m2 (542 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 13.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.61 * (1 + (-0.329/100) * (-10 - 25)) = 50.86 V | OCPD = 1.56 * 8.78 = 13.7 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-310: Voc=45.61 V, beta_Voc=-0.329%/C, Isc=8.78 A, STC=310.0 W, Area=1.938 m2.

**Result:** 11 panels max on 600 V (559.5 V); 26 panels for 8 kW (542 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-72-310?

Complete CEC test sheet for JA Solar JAP6-72-310 including Isc (8.78 A), Voc (45.61 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-310.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 281.0 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.61 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.49 V / 8.41 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.329 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.99% (1.938 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-72-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-72-310.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 417 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 688 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-72-310 series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the JA Solar JAP6-72-310 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-72-300** | 300.0 W | 271.7 W | 45.31 V | 36.74 V | 15.48% |
| **JA Solar JAP6-72-305** | 305.0 W | 276.3 W | 45.42 V | 36.36 V | 15.73% |
| **JA Solar JAP6-72-310** | 310.0 W | 281.0 W | 45.61 V | 36.49 V | 15.99% |
| **JA Solar JAP6-72-315** | 315.0 W | 285.6 W | 45.91 V | 36.72 V | 16.25% |

## How Many JA Solar JAP6-72-310 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-72-310 (45.61 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.61V and beta_Voc=-0.329%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.36 V | 11 panels | 576.0 V | 19 panels |
| **-10 C (14 F)** | 50.86 V | 11 panels | 559.5 V | 19 panels |
| **0 C (32 F)** | 49.36 V | 12 panels | 592.3 V | 20 panels |
| **25 C (77 F STC)** | 45.61 V | 13 panels | 592.9 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-310?

Four comparable CEC modules such as DEHUI SOLAR POWER INC DH-72P-310W (310.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DEHUI SOLAR POWER INC DH-72P-310W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-inc/dehui-solar-power-inc-dh-72p-310w/) DEHUI SOLAR POWER INC | 310.0 W | Tie (0 W) | 45.6 V | 16.12% | 90.5% |
| [**Centrosolar America DM72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-310/) Centrosolar America | 310.0 W | Tie (0 W) | 45.7 V | 15.94% | 90.8% |
| [**Centrosolar America TP7 310xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-310xx/) Centrosolar America | 310.0 W | Tie (0 W) | 45.7 V | 15.89% | 90.5% |
| [**Centrosolar America TP7S 310xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7s-310xx/) Centrosolar America | 310.0 W | Tie (0 W) | 45.7 V | 15.89% | 90.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-310?

Evaluate JA Solar JAP6-72-310 (310.0 W STC, 45.61 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-310 reaches 52.36 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-72-310 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72P-310W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-310 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAP6-72-310 panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-72-310 cold Voc rises from 45.61 V to 50.86 V (beta_Voc -0.329%/C), capping a 600 V string at 11 panels (559.5 V).

### How much roof area does an 8 kW array of JA Solar JAP6-72-310 need?

An 8 kW DC system uses 26 JA Solar JAP6-72-310 modules (8,060 W STC / 7,306 W PTC), covering roughly 542 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does JA Solar JAP6-72-310 compare against DEHUI SOLAR POWER INC DH-72P-310W?

JA Solar JAP6-72-310 outputs 310.0 W STC (45.61 V Voc, rank #15,760 of 21,677), while DEHUI SOLAR POWER INC DH-72P-310W delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, DEHUI SOLAR POWER INC DH-72P-310W specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-72-310.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)