title: "JA Solar JAP6-72-255 Specs (255.0W, 43.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-72-255/
description: "CEC datasheet for JA Solar JAP6-72-255: 255.0W STC, 43.8V Voc, 32-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-72-255 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-72-255 is a 255.0 W STC (227.4 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 13.06% efficiency, 43.8 V Voc at 25 C, and 48.86 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 255.0 W

- **PTC Wattage** : 227.4 W

- **Voc @ 25C** : 43.8 V

- **Efficiency** : 13.06%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-72-255 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-72-255 (Multi-c-Si) residential solar systems.

JA Solar JAP6-72-255 delivers 130.6 W/m2 (6.85 percentage points below 19.91% CEC median) and typical 89.2% PTC-to-STC thermal output (227.4 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (672 sq ft). At -4 F (-20 C), string voltage climbs to 50.3 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Gintung Energy ASEC-260G6M (260.0 W).

## Where Does JA Solar JAP6-72-255 Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-72-255 (255.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define JA Solar JAP6-72-255?

Relative ranking of JA Solar JAP6-72-255 across nameplate watts, 89.2% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for JA Solar JAP6-72-255?

Summary of JA Solar JAP6-72-255 output rank, 8 kW array size (32 panels), efficiency rating, and 600 V string limit.

Rank #19,421 / 21,677

### 255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,384

### 13.06% Aperture Efficiency

Power density 130.6 W/m2 (6.85 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.86 V at -10 C (586.3 V string) and 50.3 V at -20 C (11 max).

 8 kW Reference Array

### 32 Panels = 8,160 W STC

Occupies 62.5 m2 (672 sq ft) producing 7,277 W PTC; NEC 690.8 OCPD floor is 12.32 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.8 * (1 + (-0.33/100) * (-10 - 25)) = 48.86 V | OCPD = 1.56 * 7.9 = 12.32 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-255: Voc=43.8 V, beta_Voc=-0.33%/C, Isc=7.9 A, STC=255.0 W, Area=1.952 m2.

**Result:** 12 panels max on 600 V (586.3 V); 32 panels for 8 kW (672 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-72-255?

Complete CEC test sheet for JA Solar JAP6-72-255 including Isc (7.9 A), Voc (43.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-255.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 227.4 W (89.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.61 V / 7.16 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.06% (1.952 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-72-255 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-72-255.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.12 kW | 504 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 32 | 8.16 kW | 672 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 40 | 10.2 kW | 840 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-72-255 series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the JA Solar JAP6-72-255 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-72-250** | 250.0 W | 222.8 W | 43.6 V | 35.26 V | 12.81% |
| **JA Solar JAP6-72-255** | 255.0 W | 227.4 W | 43.8 V | 35.61 V | 13.06% |
| **JA Solar JAP6-72-260** | 260.0 W | 232.0 W | 43.8 V | 35.76 V | 13.32% |

## How Many JA Solar JAP6-72-255 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-72-255 (43.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=43.8V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.3 V | 11 panels | 553.3 V | 19 panels |
| **-10 C (14 F)** | 48.86 V | 12 panels | 586.3 V | 20 panels |
| **0 C (32 F)** | 47.41 V | 12 panels | 568.9 V | 21 panels |
| **25 C (77 F STC)** | 43.8 V | 13 panels | 569.4 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-255?

Four comparable CEC modules such as Gintung Energy ASEC-260G6M (260.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-260G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-260g6m/) Gintung Energy | 260.0 W | +5.0 W | 43.84 V | 13.29% | 89.3% |
| [**CSI Solar Co Ltd CS6X-265P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6x-265p/) CSI Solar Co Ltd | 265.0 W | +10.0 W | 43.9 V | 14.31% | 88.8% |
| [**Gintung Energy ASEC-265G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-265g6s/) Gintung Energy | 265.0 W | +10.0 W | 44.12 V | 13.55% | 89.5% |
| [**Advance Power API-P265**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p265/) Advance Power | 265.0 W | +10.0 W | 43.27 V | 13.58% | 89.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-255?

Evaluate JA Solar JAP6-72-255 (255.0 W STC, 43.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-255 reaches 50.3 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 672 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (672 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-72-255 8 kW Residential Fit

Needs 32 modules (672 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-260G6M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 227.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-255 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAP6-72-255 panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-72-255 cold Voc rises from 43.8 V to 48.86 V (beta_Voc -0.33%/C), capping a 600 V string at 12 panels (586.3 V).

### How much roof area does an 8 kW array of JA Solar JAP6-72-255 need?

An 8 kW DC system uses 32 JA Solar JAP6-72-255 modules (8,160 W STC / 7,277 W PTC), covering roughly 672 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

### How does JA Solar JAP6-72-255 compare against Gintung Energy ASEC-260G6M?

JA Solar JAP6-72-255 outputs 255.0 W STC (43.8 V Voc, rank #19,421 of 21,677), while Gintung Energy ASEC-260G6M delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, Gintung Energy ASEC-260G6M specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-72-255.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)