title: "JA Solar JAP6-60-280/4BB/RE Specs (280.0W, 38.85V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-60-280-4bb-re/
description: "CEC datasheet for JA Solar JAP6-60-280/4BB/RE: 280.0W STC, 38.85V Voc, 29-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-60-280/4BB/RE — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-60-280/4BB/RE is a 280.0 W STC (256.7 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.12% efficiency, 38.85 V Voc at 25 C, and 42.94 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 280.0 W

- **PTC Wattage** : 256.7 W

- **Voc @ 25C** : 38.85 V

- **Efficiency** : 17.12%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-60-280/4BB/RE Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-280/4BB/RE (Multi-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAP6-60-280/4BB/RE need 22 panels for 6 kW or 29 panels (510 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (510 sq ft). Under NEC 690.7(A), beta_Voc (-0.301%/C) pushes open-circuit voltage to 42.94 V at 14 F and 44.11 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAP6-60-280/4BB/RE Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-60-280/4BB/RE (280.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define JA Solar JAP6-60-280/4BB/RE?

Relative ranking of JA Solar JAP6-60-280/4BB/RE across nameplate watts, 91.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for JA Solar JAP6-60-280/4BB/RE?

Summary of JA Solar JAP6-60-280/4BB/RE output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.

Rank #17,941 / 21,677

### 280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,307

### 17.12% Aperture Efficiency

Power density 171.3 W/m2 (2.79 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.94 V at -10 C (558.2 V string) and 44.11 V at -20 C (13 max).

 8 kW Reference Array

### 29 Panels = 8,120 W STC

Occupies 47.4 m2 (510 sq ft) producing 7,444 W PTC; NEC 690.8 OCPD floor is 14.55 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.85 * (1 + (-0.301/100) * (-10 - 25)) = 42.94 V | OCPD = 1.56 * 9.33 = 14.55 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-280/4BB/RE: Voc=38.85 V, beta_Voc=-0.301%/C, Isc=9.33 A, STC=280.0 W, Area=1.635 m2.

**Result:** 13 panels max on 600 V (558.2 V); 29 panels for 8 kW (510 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-60-280/4BB/RE?

Complete CEC test sheet for JA Solar JAP6-60-280/4BB/RE including Isc (9.33 A), Voc (38.85 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-280/4BB/RE.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 256.7 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.88 V / 8.78 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.301 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.12% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-60-280/4BB/RE Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-280/4BB/RE.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.16 kW | 387 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 29 | 8.12 kW | 510 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 36 | 10.08 kW | 634 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-60-280/4BB/RE series guide.

Sibling CEC listings grouped into the JA Solar JAP6-60-280/4BB/RE wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-60-275/4BB/RE** | 275.0 W | 252.0 W | 38.46 V | 31.54 V | 16.82% |
| **JA Solar JAP6-60-280/4BB/RE** | 280.0 W | 256.7 W | 38.85 V | 31.88 V | 17.12% |

## How Many JA Solar JAP6-60-280/4BB/RE Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-60-280/4BB/RE (38.85 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.85V and beta_Voc=-0.301%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.11 V | 13 panels | 573.4 V | 22 panels |
| **-10 C (14 F)** | 42.94 V | 13 panels | 558.2 V | 23 panels |
| **0 C (32 F)** | 41.77 V | 14 panels | 584.8 V | 23 panels |
| **25 C (77 F STC)** | 38.85 V | 15 panels | 582.8 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-280/4BB/RE?

Four comparable CEC modules such as Centrosolar America TM6 280xx (280.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America TM6 280xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6-280xx/) Centrosolar America | 280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| [**Centrosolar America TM6S 280xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6s-280xx/) Centrosolar America | 280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| [**GCL System Integration Technology Co Ltd GCL-M6/60280**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60280/) GCL System Integration Technology Co Ltd | 280.0 W | Tie (0 W) | 38.7 V | 17.18% | 90.1% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60280**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60280/) GCL System Integration Technology Co Ltd | 280.0 W | Tie (0 W) | 38.7 V | 17.18% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-280/4BB/RE?

Evaluate JA Solar JAP6-60-280/4BB/RE (280.0 W STC, 38.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-280/4BB/RE reaches 44.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 510 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (510 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-280/4BB/RE carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-60-280/4BB/RE 8 kW Residential Fit

Needs 29 modules (510 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 280xx.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-280/4BB/RE by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAP6-60-280/4BB/RE PTC wattage (256.7 W) lower than STC (280.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 256.7 W PTC (91.7% retention) across JA Solar JAP6-60-280/4BB/RE's 1.635 m2 aperture.

### Who should skip JA Solar JAP6-60-280/4BB/RE on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 JA Solar JAP6-60-280/4BB/RE panels (510 sq ft) leave unusable roof gaps vs. Centrosolar America TM6 280xx.

### What is the 1,000 V commercial string limit for JA Solar JAP6-60-280/4BB/RE?

On 1,000 V commercial inverters at -10 C (42.94 V cold Voc), JA Solar JAP6-60-280/4BB/RE fits up to 23 panels per series string.

## Related Pages

Compare JA Solar equipment, Centrosolar America TM6 280xx specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-60-280/4BB/RE.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)