title: "JA Solar JAP6-60-265/4BB Specs (265.0W, 38.05V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-60-265-4bb/
description: "CEC datasheet for JA Solar JAP6-60-265/4BB: 265.0W STC, 38.05V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-60-265/4BB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-60-265/4BB is a 265.0 W STC (245.4 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.21% efficiency, 38.05 V Voc at 25 C, and 42.06 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 265.0 W

- **PTC Wattage** : 245.4 W

- **Voc @ 25C** : 38.05 V

- **Efficiency** : 16.21%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-60-265/4BB Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-60-265/4BB handles rooftop heat (245.4 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAP6-60-265/4BB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 162.1 W/m2 (3.70 percentage points below 19.91% CEC median). Compared against Centrosolar America TM6 265xx (265.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Lower 38.05 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.16 A overcurrent floor served by a 15 A breaker.

## Where Does JA Solar JAP6-60-265/4BB Fall Across Listed CEC Models?

Where JA Solar JAP6-60-265/4BB (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAP6-60-265/4BB?

Percentile placement of JA Solar JAP6-60-265/4BB across power density (162.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAP6-60-265/4BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-265/4BB specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #18,880 / 21,677

### 265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,855

### 16.21% Aperture Efficiency

Power density 162.1 W/m2 (3.70 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.06 V at -10 C (588.8 V string) and 43.2 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,215 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,607 W PTC; NEC 690.8 OCPD floor is 14.16 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.05 * (1 + (-0.301/100) * (-10 - 25)) = 42.06 V | OCPD = 1.56 * 9.08 = 14.16 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-265/4BB: Voc=38.05 V, beta_Voc=-0.301%/C, Isc=9.08 A, STC=265.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (588.8 V); 31 panels for 8 kW (546 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-60-265/4BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-265/4BB.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-265/4BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 245.4 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.02 V / 8.54 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.301 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.21% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-60-265/4BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-265/4BB (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.09 kW | 405 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 31 | 8.21 kW | 546 sq ft | $2,055 | $3,475 |
| **10 kW Class** | 38 | 10.07 kW | 669 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-60-265/4BB architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the JA Solar JAP6-60-265/4BB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-60-255/4BB** | 255.0 W | 236.0 W | 37.61 V | 30.59 V | 15.59% |
| **JA Solar JAP6-60-260/4BB** | 260.0 W | 240.7 W | 37.84 V | 30.81 V | 15.9% |
| **JA Solar JAP6-60-265/4BB** | 265.0 W | 245.4 W | 38.05 V | 31.02 V | 16.21% |
| **JA Solar JAP6-60-270/4BB** | 270.0 W | 250.2 W | 38.27 V | 31.23 V | 16.51% |

## How Many JA Solar JAP6-60-265/4BB Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-60-265/4BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.05V and beta_Voc=-0.301%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.2 V | 13 panels | 561.6 V | 23 panels |
| **-10 C (14 F)** | 42.06 V | 14 panels | 588.8 V | 23 panels |
| **0 C (32 F)** | 40.91 V | 14 panels | 572.7 V | 24 panels |
| **25 C (77 F STC)** | 38.05 V | 15 panels | 570.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-265/4BB?

Alternative CEC solar modules from competing brands near JA Solar JAP6-60-265/4BB (265.0 W), including Centrosolar America TM6 265xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America TM6 265xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6-265xx/) Centrosolar America | 265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| [**Centrosolar America TM6S 265xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6s-265xx/) Centrosolar America | 265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60265**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60265/) GCL System Integration Technology Co Ltd | 265.0 W | Tie (0 W) | 38.1 V | 16.29% | 90.5% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60B265**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60b265/) GCL System Integration Technology Co Ltd | 265.0 W | Tie (0 W) | 38.1 V | 16.26% | 90.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-265/4BB?

Evaluate JA Solar JAP6-60-265/4BB (265.0 W STC, 38.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-265/4BB reaches 43.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-265/4BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-60-265/4BB 8 kW Residential Fit

Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 265xx.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 245.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-265/4BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-60-265/4BB?

Multiplying JA Solar JAP6-60-265/4BB's 9.08 A short-circuit current by 1.56 equals 14.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can JA Solar JAP6-60-265/4BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.06 V cold Voc at 14 F and handles 9.08 A Isc; string inverters cap JA Solar JAP6-60-265/4BB at 14 panels on 600 V.

### Is JA Solar JAP6-60-265/4BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-60-265/4BB rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, Centrosolar America TM6 265xx specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-60-265/4BB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)