title: "JA Solar JAP6-60-260/3BB Specs (260.0W, 37.98V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-60-260-3bb/
description: "CEC datasheet for JA Solar JAP6-60-260/3BB: 260.0W STC, 37.98V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-60-260/3BB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-60-260/3BB is a 260.0 W STC (234.7 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.9% efficiency, 37.98 V Voc at 25 C, and 42.1 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 234.7 W

- **Voc @ 25C** : 37.98 V

- **Efficiency** : 15.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-60-260/3BB Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAP6-60-260/3BB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 260.0 W STC and 234.7 W PTC, JA Solar JAP6-60-260/3BB sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 159.0 W/m2 (4.01 percentage points below 19.91% CEC median). Lower 37.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W rates 260.0 W.

## Where Does JA Solar JAP6-60-260/3BB Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAP6-60-260/3BB (260.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define JA Solar JAP6-60-260/3BB?

Dataset percentiles tracking JA Solar JAP6-60-260/3BB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for JA Solar JAP6-60-260/3BB?

Benchmark highlights for JA Solar JAP6-60-260/3BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,312

### 15.9% Aperture Efficiency

Power density 159.0 W/m2 (4.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.1 V at -10 C (589.4 V string) and 43.28 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,276 W PTC; NEC 690.8 OCPD floor is 14.1 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.98 * (1 + (-0.31/100) * (-10 - 25)) = 42.1 V | OCPD = 1.56 * 9.04 = 14.1 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-260/3BB: Voc=37.98 V, beta_Voc=-0.31%/C, Isc=9.04 A, STC=260.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (589.4 V); 31 panels for 8 kW (546 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-60-260/3BB?

Official CEC datasheet figures for JA Solar JAP6-60-260/3BB (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-260/3BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 234.7 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.98 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.63 V / 8.49 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.9% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-60-260/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAP6-60-260/3BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 422 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 546 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 686 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAP6-60-260/3BB mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the JA Solar JAP6-60-260/3BB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-60-250/3BB** | 250.0 W | 222.9 W | 37.54 V | 29.98 V | 15.29% |
| **JA Solar JAP6-60-255/3BB** | 255.0 W | 230.1 W | 37.82 V | 30.29 V | 15.59% |
| **JA Solar JAP6-60-260/3BB** | 260.0 W | 234.7 W | 37.98 V | 30.63 V | 15.9% |
| **JA Solar JAP6-60-265/3BB** | 265.0 W | 239.4 W | 38.14 V | 30.96 V | 16.21% |
| **JA Solar JAP6-60-270/3BB** | 270.0 W | 244.0 W | 38.3 V | 31.29 V | 16.51% |

## How Many JA Solar JAP6-60-260/3BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAP6-60-260/3BB (42.1 V at 14 F).

Computed from Voc=37.98V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.28 V | 13 panels | 562.6 V | 23 panels |
| **-10 C (14 F)** | 42.1 V | 14 panels | 589.4 V | 23 panels |
| **0 C (32 F)** | 40.92 V | 14 panels | 572.9 V | 24 panels |
| **25 C (77 F STC)** | 37.98 V | 15 panels | 569.7 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-260/3BB?

Competing CEC solar panels closest to JA Solar JAP6-60-260/3BB in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6p30-260w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 260.0 W | Tie (0 W) | 38.0 V | 16.01% | 88.5% |
| [**Chinaland Solar Energy HSE260-60M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse260-60m/) Chinaland Solar Energy | 260.0 W | Tie (0 W) | 38.0 V | 16.01% | 90.5% |
| [**Chinaland Solar Energy HSE260-60M-B**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse260-60m-b/) Chinaland Solar Energy | 260.0 W | Tie (0 W) | 38.0 V | 15.21% | 90.4% |
| [**GermanSolar USA GSP6-60-260W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-60-260w/) GermanSolar USA | 260.0 W | Tie (0 W) | 38.0 V | 15.98% | 90.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-260/3BB?

Evaluate JA Solar JAP6-60-260/3BB (260.0 W STC, 37.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-260/3BB reaches 43.28 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-260/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-60-260/3BB 8 kW Residential Fit

Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-260/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAP6-60-260/3BB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-60-260/3BB cold Voc rises from 37.98 V to 42.1 V (beta_Voc -0.31%/C), capping a 600 V string at 14 panels (589.4 V).

### How much roof area does an 8 kW array of JA Solar JAP6-60-260/3BB need?

An 8 kW DC system uses 31 JA Solar JAP6-60-260/3BB modules (8,060 W STC / 7,276 W PTC), covering roughly 546 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does JA Solar JAP6-60-260/3BB compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W?

JA Solar JAP6-60-260/3BB outputs 260.0 W STC (37.98 V Voc, rank #19,146 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-60-260/3BB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)