JA Solar JAP6-60-255/MP is a 255.0 W STC (225.6 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.59% efficiency, 37.78 V Voc at 25 C, and 42.33 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 255.0 W

- **PTC Wattage** : 225.6 W

- **Voc @ 25C** : 37.78 V

- **Efficiency** : 15.59%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-60-255/MP Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-60-255/MP handles rooftop heat (225.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAP6-60-255/MP exhibits 8.91 A short-circuit current, requiring a 13.9 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,421 of 21,677 (23.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 52.3 m2 for an 8 kW system (40 panels for 10 kW). Lower 37.78 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does JA Solar JAP6-60-255/MP Fall Across Listed CEC Models?

Where JA Solar JAP6-60-255/MP (255.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAP6-60-255/MP?

Percentile placement of JA Solar JAP6-60-255/MP across power density (156.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAP6-60-255/MP?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-255/MP specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #19,421 / 21,677

### 255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,803

### 15.59% Aperture Efficiency

Power density 156.0 W/m2 (4.32 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.33 V at -10 C (592.6 V string) and 43.63 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,160 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,219 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.78 * (1 + (-0.344/100) * (-10 - 25)) = 42.33 V | OCPD = 1.56 * 8.91 = 13.9 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-255/MP: Voc=37.78 V, beta_Voc=-0.344%/C, Isc=8.91 A, STC=255.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (592.6 V); 32 panels for 8 kW (563 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-60-255/MP?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-255/MP.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-255/MP.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 225.6 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.36 V / 8.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.344 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.59% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-60-255/MP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-255/MP (255.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.12 kW | 422 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 32 | 8.16 kW | 563 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 40 | 10.2 kW | 704 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-60-255/MP architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the JA Solar JAP6-60-255/MP wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-60-250/MP** | 250.0 W | 221.0 W | 37.71 V | 30.14 V | 15.29% |
| **JA Solar JAP6-60-255/MP** | 255.0 W | 225.6 W | 37.78 V | 30.36 V | 15.59% |
| **JA Solar JAP6-60-260/MP** | 260.0 W | 230.1 W | 37.84 V | 30.57 V | 15.9% |

## How Many JA Solar JAP6-60-255/MP Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-60-255/MP from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.78V and beta_Voc=-0.344%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.63 V | 13 panels | 567.2 V | 22 panels |
| **-10 C (14 F)** | 42.33 V | 14 panels | 592.6 V | 23 panels |
| **0 C (32 F)** | 41.03 V | 14 panels | 574.4 V | 24 panels |
| **25 C (77 F STC)** | 37.78 V | 15 panels | 566.7 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-255/MP?

Alternative CEC solar modules from competing brands near JA Solar JAP6-60-255/MP (255.0 W), including GCL System Integration Technology Co Ltd GCL-P6/60255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-P6/60255**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60255/) GCL System Integration Technology Co Ltd | 255.0 W | Tie (0 W) | 37.7 V | 15.67% | 90.4% |
| [**Advance Power API-M255**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m255/) Advance Power | 255.0 W | Tie (0 W) | 37.68 V | 15.57% | 89.5% |
| [**Eoplly New Energy Technology EP156P/60-255S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156p-60-255s-ac/) Eoplly New Energy Technology | 255.0 W | Tie (0 W) | 37.68 V | 15.6% | 89.9% |
| [**Eoplly New Energy Technology EP156M/60-255 AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-255-ac/) Eoplly New Energy Technology | 255.0 W | Tie (0 W) | 37.56 V | 15.76% | 89.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-255/MP?

Evaluate JA Solar JAP6-60-255/MP (255.0 W STC, 37.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-255/MP reaches 43.63 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (563 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-255/MP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-60-255/MP 8 kW Residential Fit

Needs 32 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60255.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 225.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-255/MP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAP6-60-255/MP PTC wattage (225.6 W) lower than STC (255.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 225.6 W PTC (88.5% retention) across JA Solar JAP6-60-255/MP's 1.635 m2 aperture.

### Who should skip JA Solar JAP6-60-255/MP on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 JA Solar JAP6-60-255/MP panels (563 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-P6/60255.

### What is the 1,000 V commercial string limit for JA Solar JAP6-60-255/MP?

On 1,000 V commercial inverters at -10 C (42.33 V cold Voc), JA Solar JAP6-60-255/MP fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-60-255/MP.

## Related Pages

Compare JA Solar equipment, GCL System Integration Technology Co Ltd GCL-P6/60255 specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-60-255/MP.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)