title: "JA Solar JAP6-60-245 Specs (245.0W, 37.68V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-60-245/
description: "CEC datasheet for JA Solar JAP6-60-245: 245.0W STC, 37.68V Voc, 33-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-60-245 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-60-245 is a 245.0 W STC (218.3 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 14.98% efficiency, 37.68 V Voc at 25 C, and 42.48 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 245.0 W

- **PTC Wattage** : 218.3 W

- **Voc @ 25C** : 37.68 V

- **Efficiency** : 14.98%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-60-245 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-245 (Multi-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAP6-60-245 need 25 panels for 6 kW or 33 panels (581 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft). Under NEC 690.7(A), beta_Voc (-0.364%/C) pushes open-circuit voltage to 42.48 V at 14 F and 43.85 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAP6-60-245 Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-60-245 (245.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define JA Solar JAP6-60-245?

Relative ranking of JA Solar JAP6-60-245 across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## What Do the Dataset Ranks Show for JA Solar JAP6-60-245?

Summary of JA Solar JAP6-60-245 output rank, 8 kW array size (33 panels), efficiency rating, and 600 V string limit.

Rank #19,942 / 21,677

### 245.0 W STC · Higher Than 7.0%

245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,761

### 14.98% Aperture Efficiency

Power density 149.8 W/m2 (4.93 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.48 V at -10 C (594.7 V string) and 43.85 V at -20 C (13 max).

 8 kW Reference Array

### 33 Panels = 8,085 W STC

Occupies 54.0 m2 (581 sq ft) producing 7,204 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.68 * (1 + (-0.364/100) * (-10 - 25)) = 42.48 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-245: Voc=37.68 V, beta_Voc=-0.364%/C, Isc=8.56 A, STC=245.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (594.7 V); 33 panels for 8 kW (581 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-60-245?

Complete CEC test sheet for JA Solar JAP6-60-245 including Isc (8.56 A), Voc (37.68 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-245.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 218.3 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.68 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.92 V / 8.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.364 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.98% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-60-245 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-245.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.12 kW | 440 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 33 | 8.09 kW | 581 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 41 | 10.04 kW | 722 sq ft | $2,513 | $4,249 |

## How Many JA Solar JAP6-60-245 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-60-245 (37.68 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.68V and beta_Voc=-0.364%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.85 V | 13 panels | 570.1 V | 22 panels |
| **-10 C (14 F)** | 42.48 V | 14 panels | 594.7 V | 23 panels |
| **0 C (32 F)** | 41.11 V | 14 panels | 575.5 V | 24 panels |
| **25 C (77 F STC)** | 37.68 V | 15 panels | 565.2 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-245?

Four comparable CEC modules such as Changzhou Nesl Solartech DJ-245DA/C-ST15 (245.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Changzhou Nesl Solartech DJ-245DA/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-245da-c-st15/) Changzhou Nesl Solartech | 245.0 W | Tie (0 W) | 37.82 V | 15.0% | 90.3% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6p30-245w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 245.0 W | Tie (0 W) | 37.5 V | 15.09% | 88.3% |
| [**GermanSolar USA GSP6-60-245W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-60-245w/) GermanSolar USA | 245.0 W | Tie (0 W) | 37.5 V | 14.89% | 89.7% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245T**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60m6-ha-0-245t/) Hanwha Qcells (Qidong) Co Ltd | 245.0 W | Tie (0 W) | 37.5 V | 14.83% | 88.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-245?

Evaluate JA Solar JAP6-60-245 (245.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-245 reaches 43.85 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-245 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-60-245 8 kW Residential Fit

Needs 33 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-245DA/C-ST15.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 218.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-245 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAP6-60-245 PTC wattage (218.3 W) lower than STC (245.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 218.3 W PTC (89.1% retention) across JA Solar JAP6-60-245's 1.635 m2 aperture.

### Who should skip JA Solar JAP6-60-245 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 33 JA Solar JAP6-60-245 panels (581 sq ft) leave unusable roof gaps vs. Changzhou Nesl Solartech DJ-245DA/C-ST15.

### What is the 1,000 V commercial string limit for JA Solar JAP6-60-245?

On 1,000 V commercial inverters at -10 C (42.48 V cold Voc), JA Solar JAP6-60-245 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-60-245.

## Related Pages

Compare JA Solar equipment, Changzhou Nesl Solartech DJ-245DA/C-ST15 specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-60-245.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)