title: "JA Solar JAP6-60-205 Specs (205.0W, 36.32V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jap6-60-205/
description: "CEC datasheet for JA Solar JAP6-60-205: 205.0W STC, 36.32V Voc, 40-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAP6-60-205 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAP6-60-205 is a 205.0 W STC (182.6 W PTC) Multi-c-Si solar module ranking #20,980 of 21,677 CEC listings (below all-CEC median; higher than 3.0% of peers). It delivers 12.54% efficiency, 36.32 V Voc at 25 C, and 40.51 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 205.0 W

- **PTC Wattage** : 182.6 W

- **Voc @ 25C** : 36.32 V

- **Efficiency** : 12.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAP6-60-205 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-205 (Multi-c-Si) residential solar systems.

JA Solar JAP6-60-205 delivers 125.4 W/m2 (7.37 percentage points below 19.91% CEC median) and typical 89.1% PTC-to-STC thermal output (182.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (704 sq ft). At -4 F (-20 C), string voltage climbs to 41.71 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with CSI Solar Co Ltd CS6P-210PX (210.0 W).

## Where Does JA Solar JAP6-60-205 Fall Across Listed CEC Models?

Comparison of JA Solar JAP6-60-205 (205.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Dataset Percentiles Define JA Solar JAP6-60-205?

Relative ranking of JA Solar JAP6-60-205 across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Do the Dataset Ranks Show for JA Solar JAP6-60-205?

Summary of JA Solar JAP6-60-205 output rank, 8 kW array size (40 panels), efficiency rating, and 600 V string limit.

Rank #20,980 / 21,677

### 205.0 W STC · Higher Than 3.0%

205.0 W STC (-180.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,509

### 12.54% Aperture Efficiency

Power density 125.4 W/m2 (7.37 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.51 V at -10 C (567.1 V string) and 41.71 V at -20 C (14 max).

 8 kW Reference Array

### 40 Panels = 8,200 W STC

Occupies 65.4 m2 (704 sq ft) producing 7,304 W PTC; NEC 690.8 OCPD floor is 12.31 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.32 * (1 + (-0.33/100) * (-10 - 25)) = 40.51 V | OCPD = 1.56 * 7.89 = 12.31 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-205: Voc=36.32 V, beta_Voc=-0.33%/C, Isc=7.89 A, STC=205.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (567.1 V); 40 panels for 8 kW (704 sq ft).

## What Are the Published CEC Specifications for JA Solar JAP6-60-205?

Complete CEC test sheet for JA Solar JAP6-60-205 including Isc (7.89 A), Voc (36.32 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-205.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 205.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 182.6 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 28.32 V / 7.24 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.54% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many JA Solar JAP6-60-205 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-205.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 30 | 6.15 kW | 528 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 40 | 8.2 kW | 704 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 49 | 10.04 kW | 862 sq ft | $2,513 | $4,249 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6-60-205 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the JA Solar JAP6-60-205 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAP6-60-200** | 200.0 W | 178.1 W | 36.15 V | 28.12 V | 12.23% |
| **JA Solar JAP6-60-205** | 205.0 W | 182.6 W | 36.32 V | 28.32 V | 12.54% |
| **JA Solar JAP6-60-210** | 210.0 W | 187.2 W | 36.49 V | 28.52 V | 12.84% |

## How Many JA Solar JAP6-60-205 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAP6-60-205 (36.32 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.32V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.71 V | 14 panels | 583.9 V | 23 panels |
| **-10 C (14 F)** | 40.51 V | 14 panels | 567.1 V | 24 panels |
| **0 C (32 F)** | 39.32 V | 15 panels | 589.8 V | 25 panels |
| **25 C (77 F STC)** | 36.32 V | 16 panels | 581.1 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-205?

Four comparable CEC modules such as CSI Solar Co Ltd CS6P-210PX (210.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6P-210PX**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-210px/) CSI Solar Co Ltd | 210.0 W | +5.0 W | 36.4 V | 13.06% | 91.6% |
| [**Hanwha Qcells (Qidong) Co Ltd SF220-30-M210**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf220-30-m210/) Hanwha Qcells (Qidong) Co Ltd | 210.0 W | +5.0 W | 36.4 V | 12.71% | 90.0% |
| [**CSI Solar Co Ltd CS6P-200P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-200p/) CSI Solar Co Ltd | 200.0 W | -5.0 W | 36.2 V | 12.43% | 91.5% |
| [**Grape Solar GS-P-200-CSPE**](https://epri-peac.com/solar-equipment/modules/grape-solar/grape-solar-gs-p-200-cspe/) Grape Solar | 200.0 W | -5.0 W | 36.2 V | 12.43% | 88.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-205?

Evaluate JA Solar JAP6-60-205 (205.0 W STC, 36.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-205 reaches 41.71 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 40 panels for an 8 kW build require 704 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (704 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-205 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAP6-60-205 8 kW Residential Fit

Needs 40 modules (704 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6P-210PX.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 182.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-205 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAP6-60-205 panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-60-205 cold Voc rises from 36.32 V to 40.51 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (567.1 V).

### How much roof area does an 8 kW array of JA Solar JAP6-60-205 need?

An 8 kW DC system uses 40 JA Solar JAP6-60-205 modules (8,200 W STC / 7,304 W PTC), covering roughly 704 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

### How does JA Solar JAP6-60-205 compare against CSI Solar Co Ltd CS6P-210PX?

JA Solar JAP6-60-205 outputs 205.0 W STC (36.32 V Voc, rank #20,980 of 21,677), while CSI Solar Co Ltd CS6P-210PX delivers 210.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, CSI Solar Co Ltd CS6P-210PX specs, utility payback rates, and NEC string calculators alongside JA Solar JAP6-60-205.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)