title: "JA Solar JAM78D30-605/MB Specs (605.0W, 53.61V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/
description: "CEC datasheet for JA Solar JAM78D30-605/MB: 605.0W STC, 53.61V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM78D30-605/MB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM78D30-605/MB is a 605.0 W STC (567.6 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 22.24% efficiency, 53.61 V Voc at 25 C, and 58.24 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 605.0 W

- **PTC Wattage** : 567.6 W

- **Voc @ 25C** : 53.61 V

- **Efficiency** : 22.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM78D30-605/MB Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM78D30-605/MB (605.0 W STC) vs. LONGi Green Energy Technology Co Ltd LR5-78HBD-605M across 5,889 CEC Mono-c-Si solar modules.

Ranking #1,214 across 21,677 CEC solar panels (top 6.1%; higher than 93.9% of peers), JA Solar JAM78D30-605/MB operates as a large-format commercial and ground-mount module sitting 195.0 W above the 410.0 W Mono-c-Si median. Higher 53.61 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677), 14 panels occupy 410 sq ft and offset roughly $2,120/yr at average US rates (or $3,585/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does JA Solar JAM78D30-605/MB Fall Across Listed CEC Models?

Plots JA Solar JAM78D30-605/MB at 605.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM78D30-605/MB?

Benchmarks JA Solar JAM78D30-605/MB on STC wattage, thermal PTC/STC retention, and 22.24 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAM78D30-605/MB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM78D30-605/MB by JA Solar.

Rank #1,214 / 21,677

### Top 6.1% STC Output

605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,578

### 22.24% Aperture Efficiency

Power density 222.4 W/m2 (2.33 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.24 V at -10 C (582.4 V string) and 59.57 V at -20 C (10 max).

 8 kW Reference Array

### 14 Panels = 8,470 W STC

Occupies 38.1 m2 (410 sq ft) producing 7,946 W PTC; NEC 690.8 OCPD floor is 21.96 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.61 * (1 + (-0.247/100) * (-10 - 25)) = 58.24 V | OCPD = 1.56 * 14.08 = 21.96 A

Inputs from CEC Modules.csv for JA Solar JAM78D30-605/MB: Voc=53.61 V, beta_Voc=-0.247%/C, Isc=14.08 A, STC=605.0 W, Area=2.72 m2.

**Result:** 10 panels max on 600 V (582.4 V); 14 panels for 8 kW (410 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM78D30-605/MB?

Laboratory test ratings recorded for JA Solar JAM78D30-605/MB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM78D30-605/MB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 567.6 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 53.61 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 45.53 V / 13.29 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.247 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.24% (2.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many JA Solar JAM78D30-605/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (410 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM78D30-605/MB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.05 kW | 293 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 14 | 8.47 kW | 410 sq ft | $2,120 | $3,585 |
| **10 kW Class** | 17 | 10.29 kW | 498 sq ft | $2,575 | $4,355 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM78D30-605/MB under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM78D30-605/MB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM78D30-600/MB** | 600.0 W | 562.8 W | 53.5 V | 45.3 V | 22.06% |
| **JA Solar JAM78D30-605/MB** | 605.0 W | 567.6 W | 53.61 V | 45.53 V | 22.24% |

## How Many JA Solar JAM78D30-605/MB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM78D30-605/MB (beta_Voc -0.247%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=53.61V and beta_Voc=-0.247%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.57 V | 10 panels | 595.7 V | 16 panels |
| **-10 C (14 F)** | 58.24 V | 10 panels | 582.4 V | 17 panels |
| **0 C (32 F)** | 56.92 V | 10 panels | 569.2 V | 17 panels |
| **25 C (77 F STC)** | 53.61 V | 11 panels | 589.7 V | 18 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM78D30-605/MB?

Closest cross-brand CEC competitors to JA Solar JAM78D30-605/MB matched near 605.0 W STC and 53.61 V Voc, led by LONGi Green Energy Technology Co Ltd LR5-78HBD-605M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**LONGi Green Energy Technology Co Ltd LR5-78HBD-605M**](https://epri-peac.com/solar-equipment/modules/longi-green-energy-technology-co-ltd/longi-green-energy-technology-co-ltd-lr5-78hbd-605m/) LONGi Green Energy Technology Co Ltd | 605.0 W | Tie (0 W) | 54.2 V | 22.24% | 94.5% |
| [**Aptos Solar Technology LLC DNA-144-BFN10-605W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bfn10-605w-dg/) Aptos Solar Technology LLC | 605.0 W | Tie (0 W) | 52.9 V | 23.45% | 95.1% |
| [**BLUESUN GROUP LIMITED BSM605M10-72HNH**](https://epri-peac.com/solar-equipment/modules/bluesun-group-limited/bluesun-group-limited-bsm605m10-72hnh/) BLUESUN GROUP LIMITED | 605.0 W | Tie (0 W) | 52.9 V | 23.45% | 95.1% |
| [**Boviet Solar Technology Co Ltd BVM7613M-605-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7613m-605-h-hc-bf/) Boviet Solar Technology Co Ltd | 605.0 W | Tie (0 W) | 54.4 V | 21.61% | 94.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM78D30-605/MB?

Evaluate JA Solar JAM78D30-605/MB (605.0 W STC, 53.61 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM78D30-605/MB reaches 59.57 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 410 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM78D30-605/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM78D30-605/MB 8 kW Residential Fit

Needs 14 modules (410 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare LONGi Green Energy Technology Co Ltd LR5-78HBD-605M.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 567.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM78D30-605/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM78D30-605/MB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM78D30-605/MB cold Voc rises from 53.61 V to 58.24 V (beta_Voc -0.247%/C), capping a 600 V string at 10 panels (582.4 V).

### How much roof area does an 8 kW array of JA Solar JAM78D30-605/MB need?

An 8 kW DC system uses 14 JA Solar JAM78D30-605/MB modules (8,470 W STC / 7,946 W PTC), covering roughly 410 sq ft and saving ~$2,120/yr at 18.54 c/kWh.

### How does JA Solar JAM78D30-605/MB compare against LONGi Green Energy Technology Co Ltd LR5-78HBD-605M?

JA Solar JAM78D30-605/MB outputs 605.0 W STC (53.61 V Voc, rank #1,214 of 21,677), while LONGi Green Energy Technology Co Ltd LR5-78HBD-605M delivers 605.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, LONGi Green Energy Technology Co Ltd LR5-78HBD-605M specs, utility payback rates, and NEC string calculators alongside JA Solar JAM78D30-605/MB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)
- [JA Solar JAM66D45-595/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-595-lb/)