JA Solar JAM72S30-555/MR is a 555.0 W STC (522.8 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 22.02% efficiency, 50.05 V Voc at 25 C, and 54.64 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 555.0 W

- **PTC Wattage** : 522.8 W

- **Voc @ 25C** : 50.05 V

- **Efficiency** : 22.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM72S30-555/MR Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM72S30-555/MR handles rooftop heat (522.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAM72S30-555/MR exhibits 14.07 A short-circuit current, requiring a 21.95 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,550 of 21,677 (145.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.8 m2 for an 8 kW system (19 panels for 10 kW). Higher 50.05 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does JA Solar JAM72S30-555/MR Fall Across Listed CEC Models?

Where JA Solar JAM72S30-555/MR (555.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM72S30-555/MR?

Percentile placement of JA Solar JAM72S30-555/MR across power density (220.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAM72S30-555/MR?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM72S30-555/MR specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #2,550 / 21,677

### Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,069

### 22.02% Aperture Efficiency

Power density 220.2 W/m2 (2.11 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.64 V at -10 C (546.4 V string) and 55.95 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,325 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,842 W PTC; NEC 690.8 OCPD floor is 21.95 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.05 * (1 + (-0.262/100) * (-10 - 25)) = 54.64 V | OCPD = 1.56 * 14.07 = 21.95 A

Inputs from CEC Modules.csv for JA Solar JAM72S30-555/MR: Voc=50.05 V, beta_Voc=-0.262%/C, Isc=14.07 A, STC=555.0 W, Area=2.52 m2.

**Result:** 10 panels max on 600 V (546.4 V); 15 panels for 8 kW (407 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM72S30-555/MR?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM72S30-555/MR.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72S30-555/MR.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 522.8 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.12 V / 13.18 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.262 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.02% (2.52 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM72S30-555/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM72S30-555/MR (555.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.11 kW | 298 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 15 | 8.32 kW | 407 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 19 | 10.54 kW | 515 sq ft | $2,638 | $4,461 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAM72S30-555/MR architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the JA Solar JAM72S30-555/MR wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM72S30-550/MR** | 550.0 W | 518.0 W | 49.9 V | 41.96 V | 21.83% |
| **JA Solar JAM72S30-555/MR** | 555.0 W | 522.8 W | 50.05 V | 42.12 V | 22.02% |

## How Many JA Solar JAM72S30-555/MR Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM72S30-555/MR from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.05V and beta_Voc=-0.262%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.95 V | 10 panels | 559.5 V | 17 panels |
| **-10 C (14 F)** | 54.64 V | 10 panels | 546.4 V | 18 panels |
| **0 C (32 F)** | 53.33 V | 11 panels | 586.6 V | 18 panels |
| **25 C (77 F STC)** | 50.05 V | 11 panels | 550.5 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S30-555/MR?

Alternative CEC solar modules from competing brands near JA Solar JAM72S30-555/MR (555.0 W), including AXITEC AC-555MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-555MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mh-144v/) AXITEC | 555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
| [**ELITE Solar ET-M772BH555GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m772bh555gl/) ELITE Solar | 555.0 W | Tie (0 W) | 50.05 V | 21.68% | 94.2% |
| [**ELITE Solar ET-M772BH555WB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m772bh555wb/) ELITE Solar | 555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
| [**ELITE Solar ET-M772BH555WW**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m772bh555ww/) ELITE Solar | 555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S30-555/MR?

Evaluate JA Solar JAM72S30-555/MR (555.0 W STC, 50.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S30-555/MR reaches 55.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S30-555/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM72S30-555/MR 8 kW Residential Fit

Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-555MH/144V.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 522.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72S30-555/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM72S30-555/MR PTC wattage (522.8 W) lower than STC (555.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 522.8 W PTC (94.2% retention) across JA Solar JAM72S30-555/MR's 2.52 m2 aperture.

### Who should skip JA Solar JAM72S30-555/MR on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 JA Solar JAM72S30-555/MR panels (407 sq ft) leave unusable roof gaps vs. AXITEC AC-555MH/144V.

### What is the 1,000 V commercial string limit for JA Solar JAM72S30-555/MR?

On 1,000 V commercial inverters at -10 C (54.64 V cold Voc), JA Solar JAM72S30-555/MR fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM72S30-555/MR.

## Related Pages

Compare JA Solar equipment, AXITEC AC-555MH/144V specs, utility payback rates, and NEC string calculators alongside JA Solar JAM72S30-555/MR.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)