title: "JA Solar JAM72S10-395/MR Specs (395.0W, 49.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72s10-395-mr/
description: "CEC datasheet for JA Solar JAM72S10-395/MR: 395.0W STC, 49.3V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM72S10-395/MR — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM72S10-395/MR is a 395.0 W STC (369.7 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 49.3 V Voc at 25 C, and 53.91 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 369.7 W

- **Voc @ 25C** : 49.3 V

- **Efficiency** : 20.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM72S10-395/MR Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM72S10-395/MR handles rooftop heat (369.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAM72S10-395/MR exhibits 10.27 A short-circuit current, requiring a 16.02 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.9 m2 for an 8 kW system (26 panels for 10 kW). Higher 49.3 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does JA Solar JAM72S10-395/MR Fall Across Listed CEC Models?

Where JA Solar JAM72S10-395/MR (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM72S10-395/MR?

Percentile placement of JA Solar JAM72S10-395/MR across power density (202.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAM72S10-395/MR?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM72S10-395/MR specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

### 20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.91 V at -10 C (593.0 V string) and 55.22 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,764 W PTC; NEC 690.8 OCPD floor is 16.02 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.3 * (1 + (-0.267/100) * (-10 - 25)) = 53.91 V | OCPD = 1.56 * 10.27 = 16.02 A

Inputs from CEC Modules.csv for JA Solar JAM72S10-395/MR: Voc=49.3 V, beta_Voc=-0.267%/C, Isc=10.27 A, STC=395.0 W, Area=1.95 m2.

**Result:** 11 panels max on 600 V (593.0 V); 21 panels for 8 kW (441 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM72S10-395/MR?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM72S10-395/MR.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72S10-395/MR.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 369.7 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.06 V / 9.62 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.267 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.26% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM72S10-395/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM72S10-395/MR (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |

## How Many JA Solar JAM72S10-395/MR Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM72S10-395/MR from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.3V and beta_Voc=-0.267%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.22 V | 10 panels | 552.2 V | 18 panels |
| **-10 C (14 F)** | 53.91 V | 11 panels | 593.0 V | 18 panels |
| **0 C (32 F)** | 52.59 V | 11 panels | 578.5 V | 19 panels |
| **25 C (77 F STC)** | 49.3 V | 12 panels | 591.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S10-395/MR?

Alternative CEC solar modules from competing brands near JA Solar JAM72S10-395/MR (395.0 W), including ELITE Solar ET-M672BH395WW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**ELITE Solar ET-M672BH395WW**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395ww/) ELITE Solar | 395.0 W | Tie (0 W) | 49.5 V | 19.85% | 93.3% |
| [**ELITE Solar ET-M672BH395GL**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m672bh395gl/) ELITE Solar | 395.0 W | Tie (0 W) | 49.6 V | 19.36% | 93.2% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-bhc-395w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-hc-395w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S10-395/MR?

Evaluate JA Solar JAM72S10-395/MR (395.0 W STC, 49.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S10-395/MR reaches 55.22 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S10-395/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM72S10-395/MR 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M672BH395WW.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72S10-395/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM72S10-395/MR PTC wattage (369.7 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 369.7 W PTC (93.6% retention) across JA Solar JAM72S10-395/MR's 1.95 m2 aperture.

### Who should skip JA Solar JAM72S10-395/MR on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 JA Solar JAM72S10-395/MR panels (441 sq ft) leave unusable roof gaps vs. ELITE Solar ET-M672BH395WW.

### What is the 1,000 V commercial string limit for JA Solar JAM72S10-395/MR?

On 1,000 V commercial inverters at -10 C (53.91 V cold Voc), JA Solar JAM72S10-395/MR fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM72S10-395/MR.

## Related Pages

Compare JA Solar equipment, ELITE Solar ET-M672BH395WW specs, utility payback rates, and NEC string calculators alongside JA Solar JAM72S10-395/MR.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)