---
title: "JA Solar JAM72S09-400/PR Specs (400.0W, 49.92V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72s09-400-pr/
description: "CEC datasheet for JA Solar JAM72S09-400/PR: 400.0W STC, 49.92V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM72S09-400/PR — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM72S09-400/PR is a 400.0 W STC (373.3 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.62% efficiency, 49.92 V Voc at 25 C, and 54.6 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 373.3 W

- **Voc @ 25C** : 49.92 V

- **Efficiency** : 20.62%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM72S09-400/PR Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM72S09-400/PR: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 400.0 W STC and 373.3 W PTC, JA Solar JAM72S09-400/PR sits +15.0 W vs all-CEC median (top 45.5%; higher than 54.5% of peers) among 21,677 listed modules. Power density reaches 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). Higher 49.92 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-400-H rates 400.0 W.

## Where Does JA Solar JAM72S09-400/PR Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM72S09-400/PR (400.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define JA Solar JAM72S09-400/PR?

Dataset percentiles tracking JA Solar JAM72S09-400/PR power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for JA Solar JAM72S09-400/PR?

Benchmark highlights for JA Solar JAM72S09-400/PR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,995

### 20.62% Aperture Efficiency

Power density 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.6 V at -10 C (546.0 V string) and 55.94 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,466 W PTC; NEC 690.8 OCPD floor is 16.11 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.92 * (1 + (-0.268/100) * (-10 - 25)) = 54.6 V | OCPD = 1.56 * 10.33 = 16.11 A

Inputs from CEC Modules.csv for JA Solar JAM72S09-400/PR: Voc=49.92 V, beta_Voc=-0.268%/C, Isc=10.33 A, STC=400.0 W, Area=1.94 m2.

**Result:** 10 panels max on 600 V (546.0 V); 20 panels for 8 kW (418 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM72S09-400/PR?

Official CEC datasheet figures for JA Solar JAM72S09-400/PR (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72S09-400/PR.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 373.3 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.78 V / 9.81 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.268 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.62% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM72S09-400/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM72S09-400/PR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 313 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 418 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 522 sq ft | $2,503 | $4,232 |

## How Many JA Solar JAM72S09-400/PR Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM72S09-400/PR (54.6 V at 14 F).

Computed from Voc=49.92V and beta_Voc=-0.268%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.94 V | 10 panels | 559.4 V | 17 panels |
| **-10 C (14 F)** | 54.6 V | 10 panels | 546.0 V | 18 panels |
| **0 C (32 F)** | 53.26 V | 11 panels | 585.9 V | 18 panels |
| **25 C (77 F STC)** | 49.92 V | 12 panels | 599.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S09-400/PR?

Competing CEC solar panels closest to JA Solar JAM72S09-400/PR in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-400-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-400-h/) Boviet Solar Technology Co Ltd | 400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc/) Boviet Solar Technology Co Ltd | 405.0 W | +5.0 W | 49.45 V | 19.95% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S09-400/PR?

Evaluate JA Solar JAM72S09-400/PR (400.0 W STC, 49.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S09-400/PR reaches 55.94 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S09-400/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM72S09-400/PR 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 373.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72S09-400/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM72S09-400/PR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72S09-400/PR cold Voc rises from 49.92 V to 54.6 V (beta_Voc -0.268%/C), capping a 600 V string at 10 panels (546.0 V).

### How much roof area does an 8 kW array of JA Solar JAM72S09-400/PR need?

An 8 kW DC system uses 20 JA Solar JAM72S09-400/PR modules (8,000 W STC / 7,466 W PTC), covering roughly 418 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does JA Solar JAM72S09-400/PR compare against Boviet Solar Technology Co Ltd BVM6612M-400-H?

JA Solar JAM72S09-400/PR outputs 400.0 W STC (49.92 V Voc, rank #9,407 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-400-H delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, Boviet Solar Technology Co Ltd BVM6612M-400-H specs, utility payback rates, and NEC string calculators alongside JA Solar JAM72S09-400/PR.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)
