Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM72S09-385/PR is a 385.0 W STC (359.0 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.85% efficiency, 49.04 V Voc at 25 C, and 53.64 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 359.0 W

- **Voc @ 25C** : 49.04 V

- **Efficiency** : 19.85%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM72S09-385/PR Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM72S09-385/PR: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from JA Solar and peers, JA Solar JAM72S09-385/PR stands 25.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,542-$2,505/yr in baseline US bill offset. Higher 49.04 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does JA Solar JAM72S09-385/PR Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM72S09-385/PR (385.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define JA Solar JAM72S09-385/PR?

Dataset percentiles tracking JA Solar JAM72S09-385/PR power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for JA Solar JAM72S09-385/PR?

Benchmark highlights for JA Solar JAM72S09-385/PR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,028

### 19.85% Aperture Efficiency

Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.64 V at -10 C (590.0 V string) and 54.95 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,539 W PTC; NEC 690.8 OCPD floor is 15.87 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.04 * (1 + (-0.268/100) * (-10 - 25)) = 53.64 V | OCPD = 1.56 * 10.17 = 15.87 A

Inputs from CEC Modules.csv for JA Solar JAM72S09-385/PR: Voc=49.04 V, beta_Voc=-0.268%/C, Isc=10.17 A, STC=385.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (590.0 V); 21 panels for 8 kW (439 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM72S09-385/PR?

Official CEC datasheet figures for JA Solar JAM72S09-385/PR (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72S09-385/PR.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 359.0 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 39.9 V / 9.65 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.268 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.85% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM72S09-385/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM72S09-385/PR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 334 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 439 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 543 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM72S09-385/PR mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the JA Solar JAM72S09-385/PR wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM72S09-375/PR** | 375.0 W | 349.4 W | 48.47 V | 39.27 V | 19.35% |
| **JA Solar JAM72S09-380/PR** | 380.0 W | 354.2 W | 48.75 V | 39.59 V | 19.61% |
| **JA Solar JAM72S09-385/PR** | 385.0 W | 359.0 W | 49.04 V | 39.9 V | 19.85% |
| **JA Solar JAM72S09-390/PR** | 390.0 W | 363.8 W | 49.35 V | 40.21 V | 20.12% |
| **JA Solar JAM72S09-395/PR** | 395.0 W | 368.6 W | 49.64 V | 40.48 V | 20.38% |

## How Many JA Solar JAM72S09-385/PR Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM72S09-385/PR (53.64 V at 14 F).

Computed from Voc=49.04V and beta_Voc=-0.268%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.95 V | 10 panels | 549.5 V | 18 panels |
| **-10 C (14 F)** | 53.64 V | 11 panels | 590.0 V | 18 panels |
| **0 C (32 F)** | 52.33 V | 11 panels | 575.6 V | 19 panels |
| **25 C (77 F STC)** | 49.04 V | 12 panels | 588.5 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S09-385/PR?

Competing CEC solar panels closest to JA Solar JAM72S09-385/PR in nameplate wattage and Voc, starting with EMMVEE Photovoltaic Power Private Limited E385M72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**EMMVEE Photovoltaic Power Private Limited E385M72**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e385m72/) EMMVEE Photovoltaic Power Private Limited | 385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S09-385/PR?

Evaluate JA Solar JAM72S09-385/PR (385.0 W STC, 49.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S09-385/PR reaches 54.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (439 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S09-385/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM72S09-385/PR 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72S09-385/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAM72S09-385/PR?

Multiplying JA Solar JAM72S09-385/PR's 10.17 A short-circuit current by 1.56 equals 15.87 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can JA Solar JAM72S09-385/PR pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.64 V cold Voc at 14 F and handles 10.17 A Isc; string inverters cap JA Solar JAM72S09-385/PR at 11 panels on 600 V.

### Is JA Solar JAM72S09-385/PR eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM72S09-385/PR rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, EMMVEE Photovoltaic Power Private Limited E385M72 specs, utility payback rates, and NEC string calculators alongside JA Solar JAM72S09-385/PR.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)