title: "JA Solar JAM72D09-385/BP Specs (385.0W, 49.11V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d09-385-bp/
description: "CEC datasheet for JA Solar JAM72D09-385/BP: 385.0W STC, 49.11V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM72D09-385/BP — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM72D09-385/BP is a 385.0 W STC (357.7 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.51% efficiency, 49.11 V Voc at 25 C, and 53.75 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 357.7 W

- **Voc @ 25C** : 49.11 V

- **Efficiency** : 19.51%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM72D09-385/BP Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM72D09-385/BP (385.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF across 5,889 CEC Mono-c-Si solar modules.

Ranking #10,723 across 21,677 CEC solar panels (at all-CEC median; higher than 49.1% of peers), JA Solar JAM72D09-385/BP operates as a compact residential or specialty off-grid module sitting 25.0 W below the 410.0 W Mono-c-Si median. Higher 49.11 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 21 panels occupy 446 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does JA Solar JAM72D09-385/BP Fall Across Listed CEC Models?

Plots JA Solar JAM72D09-385/BP at 385.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM72D09-385/BP?

Benchmarks JA Solar JAM72D09-385/BP on STC wattage, thermal PTC/STC retention, and 19.51 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAM72D09-385/BP?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM72D09-385/BP by JA Solar.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,152

### 19.51% Aperture Efficiency

Power density 195.1 W/m2 (0.40 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.75 V at -10 C (591.2 V string) and 55.08 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,512 W PTC; NEC 690.8 OCPD floor is 15.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.11 * (1 + (-0.27/100) * (-10 - 25)) = 53.75 V | OCPD = 1.56 * 10.09 = 15.74 A

Inputs from CEC Modules.csv for JA Solar JAM72D09-385/BP: Voc=49.11 V, beta_Voc=-0.27%/C, Isc=10.09 A, STC=385.0 W, Area=1.973 m2.

**Result:** 11 panels max on 600 V (591.2 V); 21 panels for 8 kW (446 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM72D09-385/BP?

Laboratory test ratings recorded for JA Solar JAM72D09-385/BP (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72D09-385/BP.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 357.7 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.11 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.33 V / 9.55 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.27 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.51% (1.973 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many JA Solar JAM72D09-385/BP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (446 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM72D09-385/BP.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 340 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 446 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 552 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM72D09-385/BP under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM72D09-385/BP wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM72D09-375/BP** | 375.0 W | 348.2 W | 48.51 V | 39.73 V | 19.01% |
| **JA Solar JAM72D09-380/BP** | 380.0 W | 353.0 W | 48.81 V | 40.02 V | 19.26% |
| **JA Solar JAM72D09-385/BP** | 385.0 W | 357.7 W | 49.11 V | 40.33 V | 19.51% |
| **JA Solar JAM72D09-390/BP** | 390.0 W | 362.5 W | 49.42 V | 40.63 V | 19.77% |

## How Many JA Solar JAM72D09-385/BP Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM72D09-385/BP (beta_Voc -0.27%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.11V and beta_Voc=-0.27%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.08 V | 10 panels | 550.8 V | 18 panels |
| **-10 C (14 F)** | 53.75 V | 11 panels | 591.2 V | 18 panels |
| **0 C (32 F)** | 52.42 V | 11 panels | 576.6 V | 19 panels |
| **25 C (77 F STC)** | 49.11 V | 12 panels | 589.3 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D09-385/BP?

Closest cross-brand CEC competitors to JA Solar JAM72D09-385/BP matched near 385.0 W STC and 49.11 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h-bf/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.15% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h-bf-dg/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.06% | 93.6% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h-hc-bf/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 18.78% | 93.6% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 18.78% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D09-385/BP?

Evaluate JA Solar JAM72D09-385/BP (385.0 W STC, 49.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D09-385/BP reaches 55.08 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (446 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72D09-385/BP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM72D09-385/BP 8 kW Residential Fit

Needs 21 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 357.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72D09-385/BP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM72D09-385/BP panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72D09-385/BP cold Voc rises from 49.11 V to 53.75 V (beta_Voc -0.27%/C), capping a 600 V string at 11 panels (591.2 V).

### How much roof area does an 8 kW array of JA Solar JAM72D09-385/BP need?

An 8 kW DC system uses 21 JA Solar JAM72D09-385/BP modules (8,085 W STC / 7,512 W PTC), covering roughly 446 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

### How does JA Solar JAM72D09-385/BP compare against Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF?

JA Solar JAM72D09-385/BP outputs 385.0 W STC (49.11 V Voc, rank #10,723 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF specs, utility payback rates, and NEC string calculators alongside JA Solar JAM72D09-385/BP.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)