title: "JA Solar JAM66D45-595/LB Specs (595.0W, 47.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-595-lb/
description: "CEC datasheet for JA Solar JAM66D45-595/LB: 595.0W STC, 47.5V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM66D45-595/LB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM66D45-595/LB is a 595.0 W STC (558.6 W PTC) Mono-c-Si solar module ranking #1,462 of 21,677 CEC listings (top 7.4%; higher than 92.6% of peers). It delivers 22.54% efficiency, 47.5 V Voc at 25 C, and 51.61 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 595.0 W

- **PTC Wattage** : 558.6 W

- **Voc @ 25C** : 47.5 V

- **Efficiency** : 22.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM66D45-595/LB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM66D45-595/LB (Mono-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAM66D45-595/LB need 11 panels for 6 kW or 14 panels (398 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.247%/C) pushes open-circuit voltage to 51.61 V at 14 F and 52.78 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does JA Solar JAM66D45-595/LB Fall Across Listed CEC Models?

Comparison of JA Solar JAM66D45-595/LB (595.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define JA Solar JAM66D45-595/LB?

Relative ranking of JA Solar JAM66D45-595/LB across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for JA Solar JAM66D45-595/LB?

Summary of JA Solar JAM66D45-595/LB output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,462 / 21,677

### Top 7.4% STC Output

595.0 W STC (+210.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,947

### 22.54% Aperture Efficiency

Power density 225.4 W/m2 (2.63 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.61 V at -10 C (567.7 V string) and 52.78 V at -20 C (11 max).

 8 kW Reference Array

### 14 Panels = 8,330 W STC

Occupies 37.0 m2 (398 sq ft) producing 7,820 W PTC; NEC 690.8 OCPD floor is 24.8 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.5 * (1 + (-0.247/100) * (-10 - 25)) = 51.61 V | OCPD = 1.56 * 15.9 = 24.8 A

Inputs from CEC Modules.csv for JA Solar JAM66D45-595/LB: Voc=47.5 V, beta_Voc=-0.247%/C, Isc=15.9 A, STC=595.0 W, Area=2.64 m2.

**Result:** 11 panels max on 600 V (567.7 V); 14 panels for 8 kW (398 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM66D45-595/LB?

Complete CEC test sheet for JA Solar JAM66D45-595/LB including Isc (15.9 A), Voc (47.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM66D45-595/LB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 595.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 558.6 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 15.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 39.27 V / 15.15 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.247 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.54% (2.64 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many JA Solar JAM66D45-595/LB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM66D45-595/LB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.54 kW | 313 sq ft | $1,637 | $2,768 |
| **8 kW Class** | 14 | 8.33 kW | 398 sq ft | $2,085 | $3,525 |
| **10 kW Class** | 17 | 10.12 kW | 483 sq ft | $2,533 | $4,283 |

## How Many JA Solar JAM66D45-595/LB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAM66D45-595/LB (47.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=47.5V and beta_Voc=-0.247%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.78 V | 11 panels | 580.6 V | 18 panels |
| **-10 C (14 F)** | 51.61 V | 11 panels | 567.7 V | 19 panels |
| **0 C (32 F)** | 50.43 V | 11 panels | 554.7 V | 19 panels |
| **25 C (77 F STC)** | 47.5 V | 12 panels | 570.0 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM66D45-595/LB?

Four comparable CEC modules such as CSI Solar Co Ltd CS62-66TB-595HP (595.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS62-66TB-595HP**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs62-66tb-595hp/) CSI Solar Co Ltd | 595.0 W | Tie (0 W) | 47.4 V | 22.71% | 95.0% |
| [**Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm8611m-595r-h-hc-bf/) Boviet Solar Technology Co Ltd | 595.0 W | Tie (0 W) | 47.65 V | 23.61% | 95.3% |
| [**Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm8611m-595r-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 595.0 W | Tie (0 W) | 47.65 V | 23.61% | 95.3% |
| [**CSI Solar Co Ltd CS62-66TB-590H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs62-66tb-590h/) CSI Solar Co Ltd | 590.0 W | -5.0 W | 47.2 V | 22.52% | 95.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM66D45-595/LB?

Evaluate JA Solar JAM66D45-595/LB (595.0 W STC, 47.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM66D45-595/LB reaches 52.78 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM66D45-595/LB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM66D45-595/LB 8 kW Residential Fit

Needs 14 modules (398 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS62-66TB-595HP.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 558.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM66D45-595/LB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM66D45-595/LB PTC wattage (558.6 W) lower than STC (595.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 558.6 W PTC (93.9% retention) across JA Solar JAM66D45-595/LB's 2.64 m2 aperture.

### Who should skip JA Solar JAM66D45-595/LB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 JA Solar JAM66D45-595/LB panels (398 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS62-66TB-595HP.

### What is the 1,000 V commercial string limit for JA Solar JAM66D45-595/LB?

On 1,000 V commercial inverters at -10 C (51.61 V cold Voc), JA Solar JAM66D45-595/LB fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM66D45-595/LB.

## Related Pages

Compare JA Solar equipment, CSI Solar Co Ltd CS62-66TB-595HP specs, utility payback rates, and NEC string calculators alongside JA Solar JAM66D45-595/LB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)