# JA Solar JAM60S01-310/PR — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM60S01-310/PR is a 310.0 W STC (288.4 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.58% efficiency, 40.3 V Voc at 25 C, and 44.12 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 288.4 W

- **Voc @ 25C** : 40.3 V

- **Efficiency** : 19.58%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM60S01-310/PR Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM60S01-310/PR (310.0 W STC) vs. DualSun SAS DualSun 310M-60-00 across 5,889 CEC Mono-c-Si solar modules.

Ranking #15,760 across 21,677 CEC solar panels (below all-CEC median; higher than 25.6% of peers), JA Solar JAM60S01-310/PR operates as a compact residential or specialty off-grid module sitting 100.0 W below the 410.0 W Mono-c-Si median. Mid-range 40.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), 26 panels occupy 443 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAM60S01-310/PR Fall Across Listed CEC Models?

Plots JA Solar JAM60S01-310/PR at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM60S01-310/PR?

Benchmarks JA Solar JAM60S01-310/PR on STC wattage, thermal PTC/STC retention, and 19.58 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAM60S01-310/PR?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM60S01-310/PR by JA Solar.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,931

### 19.58% Aperture Efficiency

Power density 195.8 W/m2 (0.33 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.12 V at -10 C (573.6 V string) and 45.21 V at -20 C (13 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 41.2 m2 (443 sq ft) producing 7,498 W PTC; NEC 690.8 OCPD floor is 15.46 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.3 * (1 + (-0.271/100) * (-10 - 25)) = 44.12 V | OCPD = 1.56 * 9.91 = 15.46 A

Inputs from CEC Modules.csv for JA Solar JAM60S01-310/PR: Voc=40.3 V, beta_Voc=-0.271%/C, Isc=9.91 A, STC=310.0 W, Area=1.583 m2.

**Result:** 13 panels max on 600 V (573.6 V); 26 panels for 8 kW (443 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM60S01-310/PR?

Laboratory test ratings recorded for JA Solar JAM60S01-310/PR (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM60S01-310/PR.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 288.4 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.84 V / 9.44 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.271 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.58% (1.583 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM60S01-310/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (443 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM60S01-310/PR.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 341 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 443 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 562 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM60S01-310/PR under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM60S01-310/PR wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM60S01-300/PR** | 300.0 W | 277.6 W | 39.85 V | 32.26 V | 18.95% |
| **JA Solar JAM60S01-305/PR** | 305.0 W | 282.4 W | 40.05 V | 32.57 V | 19.27% |
| **JA Solar JAM60S01-310/PR** | 310.0 W | 288.4 W | 40.3 V | 32.84 V | 19.58% |
| **JA Solar JAM60S01-315/PR** | 315.0 W | 293.2 W | 40.53 V | 33.16 V | 19.9% |
| **JA Solar JAM60S01-320/PR** | 320.0 W | 297.9 W | 40.8 V | 33.48 V | 20.21% |

## How Many JA Solar JAM60S01-310/PR Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM60S01-310/PR (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.3V and beta_Voc=-0.271%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.21 V | 13 panels | 587.7 V | 22 panels |
| **-10 C (14 F)** | 44.12 V | 13 panels | 573.6 V | 22 panels |
| **0 C (32 F)** | 43.03 V | 13 panels | 559.4 V | 23 panels |
| **25 C (77 F STC)** | 40.3 V | 14 panels | 564.2 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM60S01-310/PR?

Closest cross-brand CEC competitors to JA Solar JAM60S01-310/PR matched near 310.0 W STC and 40.3 V Voc, led by DualSun SAS DualSun 310M-60-00.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DualSun SAS DualSun 310M-60-00**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-310m-60-00/) DualSun SAS | 310.0 W | Tie (0 W) | 40.3 V | 18.9% | 91.4% |
| [**Bluesun Solar Energy Tech CoLtd BSM310M-60**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-energy-tech-coltd/bluesun-solar-energy-tech-coltd-bsm310m-60/) Bluesun Solar Energy Tech CoLtd | 310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
| [**Boviet Solar Technology Co Ltd BVM6610M-310**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-310/) Boviet Solar Technology Co Ltd | 310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| [**Boviet Solar Technology Co Ltd BVM6610M-310-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-310-h/) Boviet Solar Technology Co Ltd | 310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM60S01-310/PR?

Evaluate JA Solar JAM60S01-310/PR (310.0 W STC, 40.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM60S01-310/PR reaches 45.21 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 443 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (443 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM60S01-310/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM60S01-310/PR 8 kW Residential Fit

Needs 26 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 310M-60-00.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM60S01-310/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM60S01-310/PR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM60S01-310/PR cold Voc rises from 40.3 V to 44.12 V (beta_Voc -0.271%/C), capping a 600 V string at 13 panels (573.6 V).

### How much roof area does an 8 kW array of JA Solar JAM60S01-310/PR need?

An 8 kW DC system uses 26 JA Solar JAM60S01-310/PR modules (8,060 W STC / 7,498 W PTC), covering roughly 443 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does JA Solar JAM60S01-310/PR compare against DualSun SAS DualSun 310M-60-00?

JA Solar JAM60S01-310/PR outputs 310.0 W STC (40.3 V Voc, rank #15,760 of 21,677), while DualSun SAS DualSun 310M-60-00 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, DualSun SAS DualSun 310M-60-00 specs, utility payback rates, and NEC string calculators alongside JA Solar JAM60S01-310/PR.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)