title: "JA Solar JAM6(BK)-72-290/SI Specs (290.0W, 45.72V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam6-bk-72-290-si/
description: "CEC datasheet for JA Solar JAM6(BK)-72-290/SI: 290.0W STC, 45.72V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM6(BK)-72-290/SI — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6(BK)-72-290/SI is a 290.0 W STC (257.4 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.96% efficiency, 45.72 V Voc at 25 C, and 51.16 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 290.0 W

- **PTC Wattage** : 257.4 W

- **Voc @ 25C** : 45.72 V

- **Efficiency** : 14.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6(BK)-72-290/SI Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM6(BK)-72-290/SI handles rooftop heat (257.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAM6(BK)-72-290/SI exhibits 8.6 A short-circuit current, requiring a 13.42 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,253 of 21,677 (120.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 54.3 m2 for an 8 kW system (35 panels for 10 kW). Mid-range 45.72 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does JA Solar JAM6(BK)-72-290/SI Fall Across Listed CEC Models?

Where JA Solar JAM6(BK)-72-290/SI (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM6(BK)-72-290/SI?

Percentile placement of JA Solar JAM6(BK)-72-290/SI across power density (149.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAM6(BK)-72-290/SI?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM6(BK)-72-290/SI specifications.

Rank #17,253 / 21,677

### 290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,793

### 14.96% Aperture Efficiency

Power density 149.6 W/m2 (4.95 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.16 V at -10 C (562.8 V string) and 52.72 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,120 W STC

Occupies 54.3 m2 (584 sq ft) producing 7,207 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.72 * (1 + (-0.34/100) * (-10 - 25)) = 51.16 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for JA Solar JAM6(BK)-72-290/SI: Voc=45.72 V, beta_Voc=-0.34%/C, Isc=8.6 A, STC=290.0 W, Area=1.938 m2.

**Result:** 11 panels max on 600 V (562.8 V); 28 panels for 8 kW (584 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6(BK)-72-290/SI?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM6(BK)-72-290/SI.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6(BK)-72-290/SI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 257.4 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.76 V / 7.89 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.96% (1.938 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6(BK)-72-290/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM6(BK)-72-290/SI (290.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.09 kW | 438 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 28 | 8.12 kW | 584 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 35 | 10.15 kW | 730 sq ft | $2,540 | $4,296 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAM6(BK)-72-290/SI architecture.

Sibling CEC listings grouped into the JA Solar JAM6(BK)-72-290/SI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM6(BK)-72-285/SI** | 285.0 W | 252.9 W | 45.42 V | 36.63 V | 14.7% |
| **JA Solar JAM6(BK)-72-290/SI** | 290.0 W | 257.4 W | 45.72 V | 36.76 V | 14.96% |
| **JA Solar JAM6(BK)-72-295/SI** | 295.0 W | 262.0 W | 45.92 V | 36.92 V | 15.22% |

## How Many JA Solar JAM6(BK)-72-290/SI Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM6(BK)-72-290/SI from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.72V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.72 V | 11 panels | 579.9 V | 18 panels |
| **-10 C (14 F)** | 51.16 V | 11 panels | 562.8 V | 19 panels |
| **0 C (32 F)** | 49.61 V | 12 panels | 595.3 V | 20 panels |
| **25 C (77 F STC)** | 45.72 V | 13 panels | 594.4 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6(BK)-72-290/SI?

Alternative CEC solar modules from competing brands near JA Solar JAM6(BK)-72-290/SI (290.0 W), including AXITEC AC-290M/156-72S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-290M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-156-72s/) AXITEC | 290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| [**Gintung Energy GTEC-290G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6s/) Gintung Energy | 290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| [**Gintung Energy GTEC-290G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6m/) Gintung Energy | 290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| [**Centrosolar America DM72 290**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-290/) Centrosolar America | 290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6(BK)-72-290/SI?

Evaluate JA Solar JAM6(BK)-72-290/SI (290.0 W STC, 45.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6(BK)-72-290/SI reaches 52.72 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 584 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (584 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6(BK)-72-290/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6(BK)-72-290/SI 8 kW Residential Fit

Needs 28 modules (584 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 257.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6(BK)-72-290/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM6(BK)-72-290/SI PTC wattage (257.4 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 257.4 W PTC (88.8% retention) across JA Solar JAM6(BK)-72-290/SI's 1.938 m2 aperture.

### Who should skip JA Solar JAM6(BK)-72-290/SI on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 JA Solar JAM6(BK)-72-290/SI panels (584 sq ft) leave unusable roof gaps vs. AXITEC AC-290M/156-72S.

### What is the 1,000 V commercial string limit for JA Solar JAM6(BK)-72-290/SI?

On 1,000 V commercial inverters at -10 C (51.16 V cold Voc), JA Solar JAM6(BK)-72-290/SI fits up to 19 panels per series string.

## Related Pages

Compare JA Solar equipment, AXITEC AC-290M/156-72S specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6(BK)-72-290/SI.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)