title: "JA Solar JAM6-72-300 Specs (300.0W, 44.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam6-72-300/
description: "CEC datasheet for JA Solar JAM6-72-300: 300.0W STC, 44.9V Voc, 27-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM6-72-300 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6-72-300 is a 300.0 W STC (269.5 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.37% efficiency, 44.9 V Voc at 25 C, and 49.93 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 269.5 W

- **Voc @ 25C** : 44.9 V

- **Efficiency** : 15.37%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6-72-300 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM6-72-300 (Mono-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAM6-72-300 need 20 panels for 6 kW or 27 panels (567 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (567 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 49.93 V at 14 F and 51.37 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAM6-72-300 Fall Across Listed CEC Models?

Comparison of JA Solar JAM6-72-300 (300.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

## What Dataset Percentiles Define JA Solar JAM6-72-300?

Relative ranking of JA Solar JAM6-72-300 across nameplate watts, 89.8% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

## What Do the Dataset Ranks Show for JA Solar JAM6-72-300?

Summary of JA Solar JAM6-72-300 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,164

### 15.37% Aperture Efficiency

Power density 153.7 W/m2 (4.54 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.93 V at -10 C (599.2 V string) and 51.37 V at -20 C (11 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 52.7 m2 (567 sq ft) producing 7,276 W PTC; NEC 690.8 OCPD floor is 13.65 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.9 * (1 + (-0.32/100) * (-10 - 25)) = 49.93 V | OCPD = 1.56 * 8.75 = 13.65 A

Inputs from CEC Modules.csv for JA Solar JAM6-72-300: Voc=44.9 V, beta_Voc=-0.32%/C, Isc=8.75 A, STC=300.0 W, Area=1.952 m2.

**Result:** 12 panels max on 600 V (599.2 V); 27 panels for 8 kW (567 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6-72-300?

Complete CEC test sheet for JA Solar JAM6-72-300 including Isc (8.75 A), Voc (44.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-72-300.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 269.5 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.36 V / 8.03 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.37% (1.952 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6-72-300 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM6-72-300.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 420 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 567 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 714 sq ft | $2,553 | $4,317 |

## How Many JA Solar JAM6-72-300 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAM6-72-300 (44.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.9V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.37 V | 11 panels | 565.1 V | 19 panels |
| **-10 C (14 F)** | 49.93 V | 12 panels | 599.2 V | 20 panels |
| **0 C (32 F)** | 48.49 V | 12 panels | 581.9 V | 20 panels |
| **25 C (77 F STC)** | 44.9 V | 13 panels | 583.7 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-72-300?

Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN6P612T305G**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t305g/) Auxin Solar | 305.0 W | +5.0 W | 45.0 V | 15.63% | 90.3% |
| [**CSI Solar Co Ltd CS6X-310P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6x-310p/) CSI Solar Co Ltd | 310.0 W | +10.0 W | 44.9 V | 16.31% | 91.4% |
| [**Auxin Solar AXN6M612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t310/) Auxin Solar | 310.0 W | +10.0 W | 45.0 V | 15.89% | 89.4% |
| [**AXITEC AC-310P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-310p-156-72s/) AXITEC | 310.0 W | +10.0 W | 45.05 V | 16.01% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-72-300?

Evaluate JA Solar JAM6-72-300 (300.0 W STC, 44.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-72-300 reaches 51.37 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 567 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (567 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-72-300 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6-72-300 8 kW Residential Fit

Needs 27 modules (567 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 269.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-72-300 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM6-72-300 PTC wattage (269.5 W) lower than STC (300.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 269.5 W PTC (89.8% retention) across JA Solar JAM6-72-300's 1.952 m2 aperture.

### Who should skip JA Solar JAM6-72-300 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 JA Solar JAM6-72-300 panels (567 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P612T305G.

### What is the 1,000 V commercial string limit for JA Solar JAM6-72-300?

On 1,000 V commercial inverters at -10 C (49.93 V cold Voc), JA Solar JAM6-72-300 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM6-72-300.

## Related Pages

Compare JA Solar equipment, Auxin Solar AXN6P612T305G specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6-72-300.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)