title: "JA Solar JAM6-72-290/SI Specs (290.0W, 45.72V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam6-72-290-si/
description: "CEC datasheet for JA Solar JAM6-72-290/SI: 290.0W STC, 45.72V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM6-72-290/SI — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6-72-290/SI is a 290.0 W STC (257.4 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.96% efficiency, 45.72 V Voc at 25 C, and 51.16 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 290.0 W

- **PTC Wattage** : 257.4 W

- **Voc @ 25C** : 45.72 V

- **Efficiency** : 14.96%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6-72-290/SI Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM6-72-290/SI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 290.0 W STC and 257.4 W PTC, JA Solar JAM6-72-290/SI sits -95.0 W vs all-CEC median (below all-CEC median; higher than 18.8% of peers) among 21,677 listed modules. Power density reaches 149.6 W/m2 (4.95 percentage points below 19.91% CEC median). Mid-range 45.72 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer AXITEC AC-290M/156-72S rates 290.0 W.

## Where Does JA Solar JAM6-72-290/SI Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM6-72-290/SI (290.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define JA Solar JAM6-72-290/SI?

Dataset percentiles tracking JA Solar JAM6-72-290/SI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for JA Solar JAM6-72-290/SI?

Benchmark highlights for JA Solar JAM6-72-290/SI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,253 / 21,677

### 290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,793

### 14.96% Aperture Efficiency

Power density 149.6 W/m2 (4.95 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.16 V at -10 C (562.8 V string) and 52.72 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,120 W STC

Occupies 54.3 m2 (584 sq ft) producing 7,207 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.72 * (1 + (-0.34/100) * (-10 - 25)) = 51.16 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for JA Solar JAM6-72-290/SI: Voc=45.72 V, beta_Voc=-0.34%/C, Isc=8.6 A, STC=290.0 W, Area=1.938 m2.

**Result:** 11 panels max on 600 V (562.8 V); 28 panels for 8 kW (584 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6-72-290/SI?

Official CEC datasheet figures for JA Solar JAM6-72-290/SI (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-72-290/SI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 257.4 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.76 V / 7.89 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.96% (1.938 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6-72-290/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM6-72-290/SI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.09 kW | 438 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 28 | 8.12 kW | 584 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 35 | 10.15 kW | 730 sq ft | $2,540 | $4,296 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM6-72-290/SI mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the JA Solar JAM6-72-290/SI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM6-72-285/SI** | 285.0 W | 252.9 W | 45.42 V | 36.63 V | 14.7% |
| **JA Solar JAM6-72-290/SI** | 290.0 W | 257.4 W | 45.72 V | 36.76 V | 14.96% |
| **JA Solar JAM6-72-295/SI** | 295.0 W | 262.0 W | 45.92 V | 36.92 V | 15.22% |

## How Many JA Solar JAM6-72-290/SI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM6-72-290/SI (51.16 V at 14 F).

Computed from Voc=45.72V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.72 V | 11 panels | 579.9 V | 18 panels |
| **-10 C (14 F)** | 51.16 V | 11 panels | 562.8 V | 19 panels |
| **0 C (32 F)** | 49.61 V | 12 panels | 595.3 V | 20 panels |
| **25 C (77 F STC)** | 45.72 V | 13 panels | 594.4 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-72-290/SI?

Competing CEC solar panels closest to JA Solar JAM6-72-290/SI in nameplate wattage and Voc, starting with AXITEC AC-290M/156-72S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-290M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-156-72s/) AXITEC | 290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| [**Gintung Energy GTEC-290G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6s/) Gintung Energy | 290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| [**Gintung Energy GTEC-290G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-gtec-290g6m/) Gintung Energy | 290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| [**Centrosolar America DM72 290**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-290/) Centrosolar America | 290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-72-290/SI?

Evaluate JA Solar JAM6-72-290/SI (290.0 W STC, 45.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-72-290/SI reaches 52.72 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 584 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (584 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-72-290/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6-72-290/SI 8 kW Residential Fit

Needs 28 modules (584 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 257.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-72-290/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM6-72-290/SI panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM6-72-290/SI cold Voc rises from 45.72 V to 51.16 V (beta_Voc -0.34%/C), capping a 600 V string at 11 panels (562.8 V).

### How much roof area does an 8 kW array of JA Solar JAM6-72-290/SI need?

An 8 kW DC system uses 28 JA Solar JAM6-72-290/SI modules (8,120 W STC / 7,207 W PTC), covering roughly 584 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

### How does JA Solar JAM6-72-290/SI compare against AXITEC AC-290M/156-72S?

JA Solar JAM6-72-290/SI outputs 290.0 W STC (45.72 V Voc, rank #17,253 of 21,677), while AXITEC AC-290M/156-72S delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, AXITEC AC-290M/156-72S specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6-72-290/SI.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)