title: "JA Solar JAM6-72-265 Specs (265.0W, 44.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam6-72-265/
description: "CEC datasheet for JA Solar JAM6-72-265: 265.0W STC, 44.6V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM6-72-265 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6-72-265 is a 265.0 W STC (237.3 W PTC) Mono-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 13.57% efficiency, 44.6 V Voc at 25 C, and 49.6 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 265.0 W

- **PTC Wattage** : 237.3 W

- **Voc @ 25C** : 44.6 V

- **Efficiency** : 13.57%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6-72-265 Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM6-72-265 (265.0 W STC) vs. Gintung Energy ASEC-265G6S across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, JA Solar JAM6-72-265 pairs typical 89.5% PTC-to-STC thermal output (237.3 W real-world rating) with 44.6 V nominal Voc. An 8 kW residential build (8,215 W DC, 7,356 W PTC) saves ~$2,055/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Gintung Energy ASEC-265G6S offers a 265.0 W alternative.

## Where Does JA Solar JAM6-72-265 Fall Across Listed CEC Models?

Plots JA Solar JAM6-72-265 at 265.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM6-72-265?

Benchmarks JA Solar JAM6-72-265 on STC wattage, thermal PTC/STC retention, and 13.57 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAM6-72-265?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM6-72-265 by JA Solar.

Rank #18,880 / 21,677

### 265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,181

### 13.57% Aperture Efficiency

Power density 135.8 W/m2 (6.34 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.6 V at -10 C (595.2 V string) and 51.02 V at -20 C (11 max).

 8 kW Reference Array

### 31 Panels = 8,215 W STC

Occupies 60.5 m2 (651 sq ft) producing 7,356 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.6 * (1 + (-0.32/100) * (-10 - 25)) = 49.6 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for JA Solar JAM6-72-265: Voc=44.6 V, beta_Voc=-0.32%/C, Isc=8.2 A, STC=265.0 W, Area=1.952 m2.

**Result:** 12 panels max on 600 V (595.2 V); 31 panels for 8 kW (651 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6-72-265?

Laboratory test ratings recorded for JA Solar JAM6-72-265 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-72-265.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 237.3 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.33 V / 7.5 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.57% (1.952 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6-72-265 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (651 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM6-72-265.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.09 kW | 483 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 31 | 8.21 kW | 651 sq ft | $2,055 | $3,475 |
| **10 kW Class** | 38 | 10.07 kW | 798 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM6-72-265 under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM6-72-265 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM6-72-255** | 255.0 W | 228.1 W | 44.5 V | 34.93 V | 13.06% |
| **JA Solar JAM6-72-260** | 260.0 W | 232.7 W | 44.6 V | 35.14 V | 13.32% |
| **JA Solar JAM6-72-265** | 265.0 W | 237.3 W | 44.6 V | 35.33 V | 13.57% |
| **JA Solar JAM6-72-270** | 270.0 W | 241.9 W | 44.7 V | 35.33 V | 13.83% |

## How Many JA Solar JAM6-72-265 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM6-72-265 (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=44.6V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.02 V | 11 panels | 561.2 V | 19 panels |
| **-10 C (14 F)** | 49.6 V | 12 panels | 595.2 V | 20 panels |
| **0 C (32 F)** | 48.17 V | 12 panels | 578.0 V | 20 panels |
| **25 C (77 F STC)** | 44.6 V | 13 panels | 579.8 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-72-265?

Closest cross-brand CEC competitors to JA Solar JAM6-72-265 matched near 265.0 W STC and 44.6 V Voc, led by Gintung Energy ASEC-265G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-265G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-265g6s/) Gintung Energy | 265.0 W | Tie (0 W) | 44.12 V | 13.55% | 89.5% |
| [**CSI Solar Co Ltd CS6X-265P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6x-265p/) CSI Solar Co Ltd | 265.0 W | Tie (0 W) | 43.9 V | 14.31% | 88.8% |
| [**Advance Power API-M270**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m270/) Advance Power | 270.0 W | +5.0 W | 44.64 V | 13.84% | 89.0% |
| [**Auxin Solar AXN6M612T270**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t270/) Auxin Solar | 270.0 W | +5.0 W | 44.64 V | 13.84% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-72-265?

Evaluate JA Solar JAM6-72-265 (265.0 W STC, 44.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-72-265 reaches 51.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 651 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (651 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-72-265 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6-72-265 8 kW Residential Fit

Needs 31 modules (651 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-265G6S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 237.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-72-265 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAM6-72-265?

Multiplying JA Solar JAM6-72-265's 8.2 A short-circuit current by 1.56 equals 12.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can JA Solar JAM6-72-265 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.6 V cold Voc at 14 F and handles 8.2 A Isc; string inverters cap JA Solar JAM6-72-265 at 12 panels on 600 V.

### Is JA Solar JAM6-72-265 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM6-72-265 rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, Gintung Energy ASEC-265G6S specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6-72-265.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)