# JA Solar JAM6-60-260/SI — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6-60-260/SI is a 260.0 W STC (234.6 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.9% efficiency, 38.08 V Voc at 25 C, and 42.21 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 234.6 W

- **Voc @ 25C** : 38.08 V

- **Efficiency** : 15.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6-60-260/SI Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM6-60-260/SI handles rooftop heat (234.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAM6-60-260/SI exhibits 8.92 A short-circuit current, requiring a 13.92 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,146 of 21,677 (150.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 50.7 m2 for an 8 kW system (39 panels for 10 kW). Lower 38.08 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does JA Solar JAM6-60-260/SI Fall Across Listed CEC Models?

Where JA Solar JAM6-60-260/SI (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM6-60-260/SI?

Percentile placement of JA Solar JAM6-60-260/SI across power density (159.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAM6-60-260/SI?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM6-60-260/SI specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,312

### 15.9% Aperture Efficiency

Power density 159.0 W/m2 (4.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.21 V at -10 C (590.9 V string) and 43.39 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,273 W PTC; NEC 690.8 OCPD floor is 13.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.08 * (1 + (-0.31/100) * (-10 - 25)) = 42.21 V | OCPD = 1.56 * 8.92 = 13.92 A

Inputs from CEC Modules.csv for JA Solar JAM6-60-260/SI: Voc=38.08 V, beta_Voc=-0.31%/C, Isc=8.92 A, STC=260.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (590.9 V); 31 panels for 8 kW (546 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6-60-260/SI?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM6-60-260/SI.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-60-260/SI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 234.6 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.08 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.81 V / 8.44 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.31 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.9% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6-60-260/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM6-60-260/SI (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 422 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 546 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 686 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAM6-60-260/SI architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the JA Solar JAM6-60-260/SI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM6-60-250/SI** | 250.0 W | 222.1 W | 37.92 V | 30.96 V | 15.29% |
| **JA Solar JAM6-60-255/SI** | 255.0 W | 226.6 W | 38.1 V | 31.16 V | 15.59% |
| **JA Solar JAM6-60-260/SI** | 260.0 W | 234.6 W | 38.08 V | 30.81 V | 15.9% |
| **JA Solar JAM6-60-265/SI** | 265.0 W | 239.2 W | 38.26 V | 31.11 V | 16.21% |
| **JA Solar JAM6-60-270/SI** | 270.0 W | 243.8 W | 38.46 V | 31.33 V | 16.51% |

## How Many JA Solar JAM6-60-260/SI Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM6-60-260/SI from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.08V and beta_Voc=-0.31%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.39 V | 13 panels | 564.1 V | 23 panels |
| **-10 C (14 F)** | 42.21 V | 14 panels | 590.9 V | 23 panels |
| **0 C (32 F)** | 41.03 V | 14 panels | 574.4 V | 24 panels |
| **25 C (77 F STC)** | 38.08 V | 15 panels | 571.2 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-60-260/SI?

Alternative CEC solar modules from competing brands near JA Solar JAM6-60-260/SI (260.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6p30-260w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 260.0 W | Tie (0 W) | 38.0 V | 16.01% | 88.5% |
| [**Chinaland Solar Energy HSE260-60M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse260-60m/) Chinaland Solar Energy | 260.0 W | Tie (0 W) | 38.0 V | 16.01% | 90.5% |
| [**Chinaland Solar Energy HSE260-60M-B**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse260-60m-b/) Chinaland Solar Energy | 260.0 W | Tie (0 W) | 38.0 V | 15.21% | 90.4% |
| [**GermanSolar USA GSP6-60-260W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa/germansolar-usa-gsp6-60-260w/) GermanSolar USA | 260.0 W | Tie (0 W) | 38.0 V | 15.98% | 90.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-60-260/SI?

Evaluate JA Solar JAM6-60-260/SI (260.0 W STC, 38.08 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-60-260/SI reaches 43.39 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-60-260/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6-60-260/SI 8 kW Residential Fit

Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-60-260/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM6-60-260/SI PTC wattage (234.6 W) lower than STC (260.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 234.6 W PTC (90.2% retention) across JA Solar JAM6-60-260/SI's 1.635 m2 aperture.

### Who should skip JA Solar JAM6-60-260/SI on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 JA Solar JAM6-60-260/SI panels (546 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

### What is the 1,000 V commercial string limit for JA Solar JAM6-60-260/SI?

On 1,000 V commercial inverters at -10 C (42.21 V cold Voc), JA Solar JAM6-60-260/SI fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM6-60-260/SI.

## Related Pages

Compare JA Solar equipment, Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6-60-260/SI.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)