CEC PV Module

# JA Solar JAM6-60-240/SI — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6-60-240/SI is a 240.0 W STC (212.9 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.68% efficiency, 37.49 V Voc at 25 C, and 41.95 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 212.9 W

- **Voc @ 25C** : 37.49 V

- **Efficiency** : 14.68%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6-60-240/SI Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM6-60-240/SI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 240.0 W STC and 212.9 W PTC, JA Solar JAM6-60-240/SI sits -145.0 W vs all-CEC median (below all-CEC median; higher than 6.1% of peers) among 21,677 listed modules. Power density reaches 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). Lower 37.49 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer AXITEC AC-240M/156-60S rates 240.0 W.

## Where Does JA Solar JAM6-60-240/SI Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM6-60-240/SI (240.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define JA Solar JAM6-60-240/SI?

Dataset percentiles tracking JA Solar JAM6-60-240/SI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for JA Solar JAM6-60-240/SI?

Benchmark highlights for JA Solar JAM6-60-240/SI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,210

### 14.68% Aperture Efficiency

Power density 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.95 V at -10 C (587.3 V string) and 43.23 V at -20 C (13 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 55.6 m2 (598 sq ft) producing 7,239 W PTC; NEC 690.8 OCPD floor is 13.32 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.49 * (1 + (-0.34/100) * (-10 - 25)) = 41.95 V | OCPD = 1.56 * 8.54 = 13.32 A

Inputs from CEC Modules.csv for JA Solar JAM6-60-240/SI: Voc=37.49 V, beta_Voc=-0.34%/C, Isc=8.54 A, STC=240.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (587.3 V); 34 panels for 8 kW (598 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6-60-240/SI?

Official CEC datasheet figures for JA Solar JAM6-60-240/SI (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-60-240/SI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 212.9 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.56 V / 7.85 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.68% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6-60-240/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM6-60-240/SI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 440 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 598 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 739 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM6-60-240/SI mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the JA Solar JAM6-60-240/SI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM6-60-235/SI** | 235.0 W | 208.4 W | 37.19 V | 30.36 V | 14.37% |
| **JA Solar JAM6-60-240/SI** | 240.0 W | 212.9 W | 37.49 V | 30.56 V | 14.68% |
| **JA Solar JAM6-60-245/SI** | 245.0 W | 217.5 W | 37.74 V | 30.76 V | 14.98% |

## How Many JA Solar JAM6-60-240/SI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM6-60-240/SI (41.95 V at 14 F).

Computed from Voc=37.49V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.23 V | 13 panels | 562.0 V | 23 panels |
| **-10 C (14 F)** | 41.95 V | 14 panels | 587.3 V | 23 panels |
| **0 C (32 F)** | 40.68 V | 14 panels | 569.5 V | 24 panels |
| **25 C (77 F STC)** | 37.49 V | 16 panels | 599.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-60-240/SI?

Competing CEC solar panels closest to JA Solar JAM6-60-240/SI in nameplate wattage and Voc, starting with AXITEC AC-240M/156-60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-240M/156-60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-240m-156-60s/) AXITEC | 240.0 W | Tie (0 W) | 37.47 V | 14.79% | 90.4% |
| [**Heliene 60P240**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-60p240/) Heliene | 240.0 W | Tie (0 W) | 37.55 V | 14.62% | 89.2% |
| [**AXITEC AC-240P/156-60B**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-240p-156-60b/) AXITEC | 240.0 W | Tie (0 W) | 37.4 V | 14.79% | 89.5% |
| [**Centrosolar America EP6 240 BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-240-bw/) Centrosolar America | 240.0 W | Tie (0 W) | 37.64 V | 14.68% | 88.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-60-240/SI?

Evaluate JA Solar JAM6-60-240/SI (240.0 W STC, 37.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-60-240/SI reaches 43.23 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 598 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (598 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-60-240/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6-60-240/SI 8 kW Residential Fit

Needs 34 modules (598 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-240M/156-60S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-60-240/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM6-60-240/SI panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM6-60-240/SI cold Voc rises from 37.49 V to 41.95 V (beta_Voc -0.34%/C), capping a 600 V string at 14 panels (587.3 V).

### How much roof area does an 8 kW array of JA Solar JAM6-60-240/SI need?

An 8 kW DC system uses 34 JA Solar JAM6-60-240/SI modules (8,160 W STC / 7,239 W PTC), covering roughly 598 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

### How does JA Solar JAM6-60-240/SI compare against AXITEC AC-240M/156-60S?

JA Solar JAM6-60-240/SI outputs 240.0 W STC (37.49 V Voc, rank #20,160 of 21,677), while AXITEC AC-240M/156-60S delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, AXITEC AC-240M/156-60S specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6-60-240/SI.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)