# JA Solar JAM6-60-210 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM6-60-210 is a 210.0 W STC (187.8 W PTC) Mono-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 12.84% efficiency, 36.46 V Voc at 25 C, and 40.54 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 210.0 W

- **PTC Wattage** : 187.8 W

- **Voc @ 25C** : 36.46 V

- **Efficiency** : 12.84%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM6-60-210 Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM6-60-210: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Across 5,889 Mono-c-Si listings from JA Solar and peers, JA Solar JAM6-60-210 stands 200.0 W below the 410.0 W Mono-c-Si median and typical 89.4% PTC-to-STC thermal output (187.8 W real-world rating). Sizing 6 kW (29 panels) to 10 kW (48 panels) yields $1,524-$2,523/yr in baseline US bill offset. Lower 36.46 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does JA Solar JAM6-60-210 Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM6-60-210 (210.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define JA Solar JAM6-60-210?

Dataset percentiles tracking JA Solar JAM6-60-210 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

## What Do the Dataset Ranks Show for JA Solar JAM6-60-210?

Benchmark highlights for JA Solar JAM6-60-210 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #20,916 / 21,677

### 210.0 W STC · Higher Than 3.2%

210.0 W STC (-175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,463

### 12.84% Aperture Efficiency

Power density 128.4 W/m2 (7.07 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.54 V at -10 C (567.6 V string) and 41.71 V at -20 C (14 max).

 8 kW Reference Array

### 39 Panels = 8,190 W STC

Occupies 63.8 m2 (686 sq ft) producing 7,324 W PTC; NEC 690.8 OCPD floor is 12.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.46 * (1 + (-0.32/100) * (-10 - 25)) = 40.54 V | OCPD = 1.56 * 8.0 = 12.48 A

Inputs from CEC Modules.csv for JA Solar JAM6-60-210: Voc=36.46 V, beta_Voc=-0.32%/C, Isc=8.0 A, STC=210.0 W, Area=1.635 m2.

**Result:** 14 panels max on 600 V (567.6 V); 39 panels for 8 kW (686 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM6-60-210?

Official CEC datasheet figures for JA Solar JAM6-60-210 (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM6-60-210.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 210.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 187.8 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 28.28 V / 7.43 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.84% (1.635 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM6-60-210 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM6-60-210 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 29 | 6.09 kW | 510 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 39 | 8.19 kW | 686 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 48 | 10.08 kW | 845 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM6-60-210 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the JA Solar JAM6-60-210 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM6-60-200** | 200.0 W | 178.6 W | 36.12 V | 27.88 V | 12.23% |
| **JA Solar JAM6-60-205** | 205.0 W | 183.2 W | 36.29 V | 28.08 V | 12.54% |
| **JA Solar JAM6-60-210** | 210.0 W | 187.8 W | 36.46 V | 28.28 V | 12.84% |
| **JA Solar JAM6-60-215** | 215.0 W | 192.4 W | 36.63 V | 28.48 V | 13.15% |
| **JA Solar JAM6-60-220** | 220.0 W | 197.0 W | 36.8 V | 28.68 V | 13.45% |

## How Many JA Solar JAM6-60-210 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM6-60-210 (40.54 V at 14 F).

Computed from Voc=36.46V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.71 V | 14 panels | 583.9 V | 23 panels |
| **-10 C (14 F)** | 40.54 V | 14 panels | 567.6 V | 24 panels |
| **0 C (32 F)** | 39.38 V | 15 panels | 590.7 V | 25 panels |
| **25 C (77 F STC)** | 36.46 V | 16 panels | 583.4 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-60-210?

Competing CEC solar panels closest to JA Solar JAM6-60-210 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6P-210PX.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6P-210PX**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-210px/) CSI Solar Co Ltd | 210.0 W | Tie (0 W) | 36.4 V | 13.06% | 91.6% |
| [**Hanwha Qcells (Qidong) Co Ltd SF220-30-M210**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf220-30-m210/) Hanwha Qcells (Qidong) Co Ltd | 210.0 W | Tie (0 W) | 36.4 V | 12.71% | 90.0% |
| [**Hanwha Qcells (Qidong) Co Ltd SF220-30-P210**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf220-30-p210/) Hanwha Qcells (Qidong) Co Ltd | 210.0 W | Tie (0 W) | 36.2 V | 12.71% | 90.1% |
| [**Hanwha Qcells (Qidong) Co Ltd SF220-30-P210B**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf220-30-p210b/) Hanwha Qcells (Qidong) Co Ltd | 210.0 W | Tie (0 W) | 36.1 V | 12.71% | 89.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-60-210?

Evaluate JA Solar JAM6-60-210 (210.0 W STC, 36.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-60-210 reaches 41.71 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 686 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (686 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-60-210 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM6-60-210 8 kW Residential Fit

Needs 39 modules (686 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6P-210PX.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 187.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM6-60-210 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for JA Solar JAM6-60-210?

Multiplying JA Solar JAM6-60-210's 8.0 A short-circuit current by 1.56 equals 12.48 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can JA Solar JAM6-60-210 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.54 V cold Voc at 14 F and handles 8.0 A Isc; string inverters cap JA Solar JAM6-60-210 at 14 panels on 600 V.

### Is JA Solar JAM6-60-210 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM6-60-210 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare JA Solar equipment, CSI Solar Co Ltd CS6P-210PX specs, utility payback rates, and NEC string calculators alongside JA Solar JAM6-60-210.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)