title: "JA Solar JAM54S31-390/MR Specs (390.0W, 36.85V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam54s31-390-mr/
description: "CEC datasheet for JA Solar JAM54S31-390/MR: 390.0W STC, 36.85V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM54S31-390/MR — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM54S31-390/MR is a 390.0 W STC (363.9 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.53% efficiency, 36.85 V Voc at 25 C, and 40.19 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 363.9 W

- **Voc @ 25C** : 36.85 V

- **Efficiency** : 20.53%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM54S31-390/MR Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM54S31-390/MR: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 390.0 W STC and 363.9 W PTC, JA Solar JAM54S31-390/MR sits +5.0 W vs all-CEC median (top 49.5%; higher than 50.5% of peers) among 21,677 listed modules. Power density reaches 205.3 W/m2 (0.62 percentage points above 19.91% CEC median). Lower 36.85 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Apollo Renewables Inc Apollo-M754BH-390BB rates 390.0 W.

## Where Does JA Solar JAM54S31-390/MR Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM54S31-390/MR (390.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define JA Solar JAM54S31-390/MR?

Dataset percentiles tracking JA Solar JAM54S31-390/MR power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for JA Solar JAM54S31-390/MR?

Benchmark highlights for JA Solar JAM54S31-390/MR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,442

### 20.53% Aperture Efficiency

Power density 205.3 W/m2 (0.62 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.19 V at -10 C (562.7 V string) and 41.14 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 39.9 m2 (429 sq ft) producing 7,642 W PTC; NEC 690.8 OCPD floor is 21.23 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.85 * (1 + (-0.259/100) * (-10 - 25)) = 40.19 V | OCPD = 1.56 * 13.61 = 21.23 A

Inputs from CEC Modules.csv for JA Solar JAM54S31-390/MR: Voc=36.85 V, beta_Voc=-0.259%/C, Isc=13.61 A, STC=390.0 W, Area=1.9 m2.

**Result:** 14 panels max on 600 V (562.7 V); 21 panels for 8 kW (429 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM54S31-390/MR?

Official CEC datasheet figures for JA Solar JAM54S31-390/MR (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM54S31-390/MR.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 363.9 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.64 V / 12.73 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.259 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.53% (1.9 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM54S31-390/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM54S31-390/MR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 327 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 429 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 532 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM54S31-390/MR mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the JA Solar JAM54S31-390/MR wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM54S31-385/MR** | 385.0 W | 359.1 W | 36.71 V | 30.46 V | 20.26% |
| **JA Solar JAM54S31-390/MR** | 390.0 W | 363.9 W | 36.85 V | 30.64 V | 20.53% |
| **JA Solar JAM54S31-395/MR** | 395.0 W | 368.7 W | 36.98 V | 30.84 V | 20.79% |

## How Many JA Solar JAM54S31-390/MR Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM54S31-390/MR (40.19 V at 14 F).

Computed from Voc=36.85V and beta_Voc=-0.259%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.14 V | 14 panels | 576.0 V | 24 panels |
| **-10 C (14 F)** | 40.19 V | 14 panels | 562.7 V | 24 panels |
| **0 C (32 F)** | 39.24 V | 15 panels | 588.6 V | 25 panels |
| **25 C (77 F STC)** | 36.85 V | 16 panels | 589.6 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM54S31-390/MR?

Competing CEC solar panels closest to JA Solar JAM54S31-390/MR in nameplate wattage and Voc, starting with Apollo Renewables Inc Apollo-M754BH-390BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Apollo Renewables Inc Apollo-M754BH-390BB**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m754bh-390bb/) Apollo Renewables Inc | 390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| [**AXITEC AC-390MH/108VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-390mh-108vb/) AXITEC | 390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| [**ELITE Solar ET-M754BH390BB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m754bh390bb/) ELITE Solar | 390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| [**DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M**](https://epri-peac.com/solar-equipment/modules/dongguan-sunworth-solar-energy-co-ltd/dongguan-sunworth-solar-energy-co-ltd-sw390m/) DONGGUAN SUNWORTH SOLAR ENERGY CO LTD | 390.0 W | Tie (0 W) | 36.45 V | 20.53% | 94.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM54S31-390/MR?

Evaluate JA Solar JAM54S31-390/MR (390.0 W STC, 36.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM54S31-390/MR reaches 41.14 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (429 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM54S31-390/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM54S31-390/MR 8 kW Residential Fit

Needs 21 modules (429 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-390BB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 363.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM54S31-390/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM54S31-390/MR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM54S31-390/MR cold Voc rises from 36.85 V to 40.19 V (beta_Voc -0.259%/C), capping a 600 V string at 14 panels (562.7 V).

### How much roof area does an 8 kW array of JA Solar JAM54S31-390/MR need?

An 8 kW DC system uses 21 JA Solar JAM54S31-390/MR modules (8,190 W STC / 7,642 W PTC), covering roughly 429 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

### How does JA Solar JAM54S31-390/MR compare against Apollo Renewables Inc Apollo-M754BH-390BB?

JA Solar JAM54S31-390/MR outputs 390.0 W STC (36.85 V Voc, rank #10,321 of 21,677), while Apollo Renewables Inc Apollo-M754BH-390BB delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, Apollo Renewables Inc Apollo-M754BH-390BB specs, utility payback rates, and NEC string calculators alongside JA Solar JAM54S31-390/MR.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)