CEC PV Module

# JA Solar JAM54D41-435/MB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM54D41-435/MB is a 435.0 W STC (412.6 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 23.02% efficiency, 39.11 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 412.6 W

- **Voc @ 25C** : 39.11 V

- **Efficiency** : 23.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM54D41-435/MB Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM54D41-435/MB handles rooftop heat (412.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAM54D41-435/MB exhibits 13.8 A short-circuit current, requiring a 21.53 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #6,850 of 21,677 (25.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 35.9 m2 for an 8 kW system (23 panels for 10 kW). Lower 39.11 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does JA Solar JAM54D41-435/MB Fall Across Listed CEC Models?

Where JA Solar JAM54D41-435/MB (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM54D41-435/MB?

Percentile placement of JA Solar JAM54D41-435/MB across power density (230.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for JA Solar JAM54D41-435/MB?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM54D41-435/MB specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,124

### 23.02% Aperture Efficiency

Power density 230.2 W/m2 (3.11 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 42.98 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 35.9 m2 (387 sq ft) producing 7,839 W PTC; NEC 690.8 OCPD floor is 21.53 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.11 * (1 + (-0.22/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 13.8 = 21.53 A

Inputs from CEC Modules.csv for JA Solar JAM54D41-435/MB: Voc=39.11 V, beta_Voc=-0.22%/C, Isc=13.8 A, STC=435.0 W, Area=1.89 m2.

**Result:** 14 panels max on 600 V (589.7 V); 19 panels for 8 kW (387 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM54D41-435/MB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM54D41-435/MB.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM54D41-435/MB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 412.6 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.11 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.13 V / 13.13 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.22 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.02% (1.89 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many JA Solar JAM54D41-435/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM54D41-435/MB (435.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 285 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 387 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 468 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAM54D41-435/MB architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the JA Solar JAM54D41-435/MB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM54D41-425/MB** | 425.0 W | 402.9 W | 38.56 V | 32.64 V | 22.49% |
| **JA Solar JAM54D41-430/MB** | 430.0 W | 407.8 W | 38.84 V | 32.88 V | 22.75% |
| **JA Solar JAM54D41-435/MB** | 435.0 W | 412.6 W | 39.11 V | 33.13 V | 23.02% |
| **JA Solar JAM54D41-440/MB** | 440.0 W | 417.5 W | 39.38 V | 33.37 V | 23.28% |

## How Many JA Solar JAM54D41-435/MB Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM54D41-435/MB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.11V and beta_Voc=-0.22%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.98 V | 13 panels | 558.7 V | 23 panels |
| **-10 C (14 F)** | 42.12 V | 14 panels | 589.7 V | 23 panels |
| **0 C (32 F)** | 41.26 V | 14 panels | 577.6 V | 24 panels |
| **25 C (77 F STC)** | 39.11 V | 15 panels | 586.6 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM54D41-435/MB?

Alternative CEC solar modules from competing brands near JA Solar JAM54D41-435/MB (435.0 W), including Aptos Solar Technology LLC DNA-108-BFN10-435W-DG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-BFN10-435W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bfn10-435w-dg/) Aptos Solar Technology LLC | 435.0 W | Tie (0 W) | 39.0 V | 22.42% | 94.9% |
| [**AMPS Solar AMPS-435N-108BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-435n-108bb/) AMPS Solar | 435.0 W | Tie (0 W) | 39.69 V | 22.42% | 95.1% |
| [**CertainTeed CTTC435HC12-08**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc435hc12-08/) CertainTeed | 435.0 W | Tie (0 W) | 38.5 V | 22.31% | 94.8% |
| [**Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-430-h-hc-bf/) Boviet Solar Technology Co Ltd | 430.0 W | -5.0 W | 39.04 V | 19.91% | 94.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM54D41-435/MB?

Evaluate JA Solar JAM54D41-435/MB (435.0 W STC, 39.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM54D41-435/MB reaches 42.98 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 387 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (387 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM54D41-435/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM54D41-435/MB 8 kW Residential Fit

Needs 19 modules (387 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BFN10-435W-DG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 412.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM54D41-435/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM54D41-435/MB PTC wattage (412.6 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.6 W PTC (94.9% retention) across JA Solar JAM54D41-435/MB's 1.89 m2 aperture.

### Who should skip JA Solar JAM54D41-435/MB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 JA Solar JAM54D41-435/MB panels (387 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-BFN10-435W-DG.

### What is the 1,000 V commercial string limit for JA Solar JAM54D41-435/MB?

On 1,000 V commercial inverters at -10 C (42.12 V cold Voc), JA Solar JAM54D41-435/MB fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM54D41-435/MB.

## Related Pages

Compare JA Solar equipment, Aptos Solar Technology LLC DNA-108-BFN10-435W-DG specs, utility payback rates, and NEC string calculators alongside JA Solar JAM54D41-435/MB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)