title: "JA Solar JAM54D30-395/MB Specs (395.0W, 36.98V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam54d30-395-mb/
description: "CEC datasheet for JA Solar JAM54D30-395/MB: 395.0W STC, 36.98V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM54D30-395/MB — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM54D30-395/MB is a 395.0 W STC (370.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.79% efficiency, 36.98 V Voc at 25 C, and 40.19 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 370.0 W

- **Voc @ 25C** : 36.98 V

- **Efficiency** : 20.79%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM54D30-395/MB Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM54D30-395/MB (395.0 W STC) vs. AXITEC AC-395MBT/108V across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), JA Solar JAM54D30-395/MB operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Lower 36.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), 21 panels occupy 429 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does JA Solar JAM54D30-395/MB Fall Across Listed CEC Models?

Plots JA Solar JAM54D30-395/MB at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define JA Solar JAM54D30-395/MB?

Benchmarks JA Solar JAM54D30-395/MB on STC wattage, thermal PTC/STC retention, and 20.79 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for JA Solar JAM54D30-395/MB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM54D30-395/MB by JA Solar.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,247

### 20.79% Aperture Efficiency

Power density 207.9 W/m2 (0.88 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.19 V at -10 C (562.7 V string) and 41.11 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 39.9 m2 (429 sq ft) producing 7,770 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.98 * (1 + (-0.248/100) * (-10 - 25)) = 40.19 V | OCPD = 1.56 * 13.7 = 21.37 A

Inputs from CEC Modules.csv for JA Solar JAM54D30-395/MB: Voc=36.98 V, beta_Voc=-0.248%/C, Isc=13.7 A, STC=395.0 W, Area=1.9 m2.

**Result:** 14 panels max on 600 V (562.7 V); 21 panels for 8 kW (429 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM54D30-395/MB?

Laboratory test ratings recorded for JA Solar JAM54D30-395/MB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM54D30-395/MB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 370.0 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.98 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.84 V / 12.81 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.248 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.79% (1.9 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many JA Solar JAM54D30-395/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (429 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM54D30-395/MB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 327 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 429 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 532 sq ft | $2,570 | $4,347 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM54D30-395/MB under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM54D30-395/MB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM54D30-390/MB** | 390.0 W | 365.2 W | 36.85 V | 30.64 V | 20.53% |
| **JA Solar JAM54D30-395/MB** | 395.0 W | 370.0 W | 36.98 V | 30.84 V | 20.79% |

## How Many JA Solar JAM54D30-395/MB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM54D30-395/MB (beta_Voc -0.248%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.98V and beta_Voc=-0.248%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.11 V | 14 panels | 575.5 V | 24 panels |
| **-10 C (14 F)** | 40.19 V | 14 panels | 562.7 V | 24 panels |
| **0 C (32 F)** | 39.27 V | 15 panels | 589.1 V | 25 panels |
| **25 C (77 F STC)** | 36.98 V | 16 panels | 591.7 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM54D30-395/MB?

Closest cross-brand CEC competitors to JA Solar JAM54D30-395/MB matched near 395.0 W STC and 36.98 V Voc, led by AXITEC AC-395MBT/108V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-395MBT/108V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-395mbt-108v/) AXITEC | 395.0 W | Tie (0 W) | 37.0 V | 20.47% | 93.3% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-BF-395**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-bf-395/) Elin Energy (Sirius PV) | 395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.3% |
| [**Belinus Solar BV BE-M7-GG-108-395**](https://epri-peac.com/solar-equipment/modules/belinus-solar-bv/belinus-solar-bv-be-m7-gg-108-395/) Belinus Solar BV | 395.0 W | Tie (0 W) | 37.03 V | 20.26% | 93.8% |
| [**ASTORIOS Holding Inc ASTR108BDG-395W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr108bdg-395w-us/) ASTORIOS Holding Inc | 395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM54D30-395/MB?

Evaluate JA Solar JAM54D30-395/MB (395.0 W STC, 36.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM54D30-395/MB reaches 41.11 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (429 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM54D30-395/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM54D30-395/MB 8 kW Residential Fit

Needs 21 modules (429 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-395MBT/108V.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 370.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM54D30-395/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many JA Solar JAM54D30-395/MB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM54D30-395/MB cold Voc rises from 36.98 V to 40.19 V (beta_Voc -0.248%/C), capping a 600 V string at 14 panels (562.7 V).

### How much roof area does an 8 kW array of JA Solar JAM54D30-395/MB need?

An 8 kW DC system uses 21 JA Solar JAM54D30-395/MB modules (8,295 W STC / 7,770 W PTC), covering roughly 429 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

### How does JA Solar JAM54D30-395/MB compare against AXITEC AC-395MBT/108V?

JA Solar JAM54D30-395/MB outputs 395.0 W STC (36.98 V Voc, rank #9,869 of 21,677), while AXITEC AC-395MBT/108V delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare JA Solar equipment, AXITEC AC-395MBT/108V specs, utility payback rates, and NEC string calculators alongside JA Solar JAM54D30-395/MB.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)