title: "JA Solar JAM5-72-165 Specs (165.0W, 44.79V Voc)"
url: https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam5-72-165/
description: "CEC datasheet for JA Solar JAM5-72-165: 165.0W STC, 44.79V Voc, 49-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# JA Solar JAM5-72-165 — CEC Solar Module Specifications

Manufacturer: [**JA Solar**](https://epri-peac.com/solar-equipment/brands/ja-solar/) Registry: **CEC Verified Engineering Specification**

JA Solar JAM5-72-165 is a 165.0 W STC (148.0 W PTC) Mono-c-Si solar module ranking #21,351 of 21,677 CEC listings (below all-CEC median; higher than 1.4% of peers). It delivers 12.92% efficiency, 44.79 V Voc at 25 C, and 49.81 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 165.0 W

- **PTC Wattage** : 148.0 W

- **Voc @ 25C** : 44.79 V

- **Efficiency** : 12.92%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does JA Solar JAM5-72-165 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM5-72-165 (Mono-c-Si) residential solar systems.

Homeowners evaluating JA Solar JAM5-72-165 need 37 panels for 6 kW or 49 panels (674 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 49.81 V at 14 F and 51.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does JA Solar JAM5-72-165 Fall Across Listed CEC Models?

Comparison of JA Solar JAM5-72-165 (165.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Dataset Percentiles Define JA Solar JAM5-72-165?

Relative ranking of JA Solar JAM5-72-165 across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Do the Dataset Ranks Show for JA Solar JAM5-72-165?

Summary of JA Solar JAM5-72-165 output rank, 8 kW array size (49 panels), efficiency rating, and 600 V string limit.

Rank #21,351 / 21,677

### 165.0 W STC · Higher Than 1.4%

165.0 W STC (-220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,422

### 12.92% Aperture Efficiency

Power density 129.2 W/m2 (6.99 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.81 V at -10 C (597.7 V string) and 51.24 V at -20 C (11 max).

 8 kW Reference Array

### 49 Panels = 8,085 W STC

Occupies 62.6 m2 (674 sq ft) producing 7,252 W PTC; NEC 690.8 OCPD floor is 7.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.79 * (1 + (-0.32/100) * (-10 - 25)) = 49.81 V | OCPD = 1.56 * 5.03 = 7.85 A

Inputs from CEC Modules.csv for JA Solar JAM5-72-165: Voc=44.79 V, beta_Voc=-0.32%/C, Isc=5.03 A, STC=165.0 W, Area=1.277 m2.

**Result:** 12 panels max on 600 V (597.7 V); 49 panels for 8 kW (674 sq ft).

## What Are the Published CEC Specifications for JA Solar JAM5-72-165?

Complete CEC test sheet for JA Solar JAM5-72-165 including Isc (5.03 A), Voc (44.79 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM5-72-165.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 165.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 148.0 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.79 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.2 V / 4.56 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.92% (1.277 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many JA Solar JAM5-72-165 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM5-72-165.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 37 | 6.11 kW | 509 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 49 | 8.09 kW | 674 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 61 | 10.06 kW | 838 sq ft | $2,518 | $4,258 |

## Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM5-72-165 series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the JA Solar JAM5-72-165 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **JA Solar JAM5-72-165** | 165.0 W | 148.0 W | 44.79 V | 36.2 V | 12.92% |
| **JA Solar JAM5-72-170** | 170.0 W | 152.6 W | 44.96 V | 36.4 V | 13.32% |

## How Many JA Solar JAM5-72-165 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAM5-72-165 (44.79 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.79V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 51.24 V | 11 panels | 563.6 V | 19 panels |
| **-10 C (14 F)** | 49.81 V | 12 panels | 597.7 V | 20 panels |
| **0 C (32 F)** | 48.37 V | 12 panels | 580.4 V | 20 panels |
| **25 C (77 F STC)** | 44.79 V | 13 panels | 582.3 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM5-72-165?

Four comparable CEC modules such as Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B (165.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf160-24-m165b/) Hanwha Qcells (Qidong) Co Ltd | 165.0 W | Tie (0 W) | 44.0 V | 12.92% | 90.1% |
| [**Enp Sonne Solar Technikk ENP-M170MO**](https://epri-peac.com/solar-equipment/modules/enp-sonne-solar-technikk/enp-sonne-solar-technikk-enp-m170mo/) Enp Sonne Solar Technikk | 170.0 W | +5.0 W | 44.2 V | 13.29% | 89.3% |
| [**Hanwha Qcells (Qidong) Co Ltd SF160-24-P170**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf160-24-p170/) Hanwha Qcells (Qidong) Co Ltd | 170.0 W | +5.0 W | 44.1 V | 13.32% | 88.2% |
| [**Jiangyin Hareon Power HR-170W/24V**](https://epri-peac.com/solar-equipment/modules/jiangyin-hareon-power/jiangyin-hareon-power-hr-170w-24v/) Jiangyin Hareon Power | 170.0 W | +5.0 W | 43.8 V | 13.32% | 89.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for JA Solar JAM5-72-165?

Evaluate JA Solar JAM5-72-165 (165.0 W STC, 44.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM5-72-165 reaches 51.24 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 49 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 49 panels (674 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM5-72-165 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### JA Solar JAM5-72-165 8 kW Residential Fit

Needs 49 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 148.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM5-72-165 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is JA Solar JAM5-72-165 PTC wattage (148.0 W) lower than STC (165.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 148.0 W PTC (89.7% retention) across JA Solar JAM5-72-165's 1.277 m2 aperture.

### Who should skip JA Solar JAM5-72-165 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 49 JA Solar JAM5-72-165 panels (674 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B.

### What is the 1,000 V commercial string limit for JA Solar JAM5-72-165?

On 1,000 V commercial inverters at -10 C (49.81 V cold Voc), JA Solar JAM5-72-165 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM5-72-165.

## Related Pages

Compare JA Solar equipment, Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B specs, utility payback rates, and NEC string calculators alongside JA Solar JAM5-72-165.

[All JA Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/ja-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From JA Solar

- [All JA Solar Specs](https://epri-peac.com/solar-equipment/brands/ja-solar/)
- [JA Solar JAM66D45-635/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-635-lb/)
- [JA Solar JAM66D45-610/LB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/)
- [JA Solar JAM78D30-605/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam78d30-605-mb/)
- [JA Solar JAM72D40-600/MB](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb/)
- [JA Solar JAM72D40-600/MB-US](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam72d40-600-mb-us/)