title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs hyundai-energy #4"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s420vj/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ: 420.0W STC, 52.0V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ is a 420.0 W STC (381.0 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.27% efficiency, 52.0 V Voc at 25 C, and 57.95 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 381.0 W

- **Voc @ 25C** : 52.0 V

- **Efficiency** : 19.27%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ Compare Against Peer CEC Listings?

How HYUNDAI ENERGY SOLUTIONS CO LTD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ handles rooftop heat (381.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ exhibits 10.22 A short-circuit current, requiring a 15.94 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #7,910 of 21,677 (10.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 43.6 m2 for an 8 kW system (24 panels for 10 kW). Higher 52.0 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ Fall Across Listed CEC Models?

Where HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ?

Percentile placement of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ across power density (192.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ?

Four critical engineering numbers homeowners and solar installers check first when reviewing HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ specifications.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,821

### 19.27% Aperture Efficiency

Power density 192.7 W/m2 (0.64 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.95 V at -10 C (579.5 V string) and 59.65 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 43.6 m2 (469 sq ft) producing 7,620 W PTC; NEC 690.8 OCPD floor is 15.94 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.0 * (1 + (-0.327/100) * (-10 - 25)) = 57.95 V | OCPD = 1.56 * 10.22 = 15.94 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ: Voc=52.0 V, beta_Voc=-0.327%/C, Isc=10.22 A, STC=420.0 W, Area=2.18 m2.

**Result:** 10 panels max on 600 V (579.5 V); 20 panels for 8 kW (469 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 381.0 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 52.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 43.2 V / 9.73 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.327 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.27% (2.18 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 352 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 469 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 563 sq ft | $2,523 | $4,266 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ Modules Fit in a Cold-Weather String?

Maximum series module counts for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.0V and beta_Voc=-0.327%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 59.65 V | 10 panels | 596.5 V | 16 panels |
| **-10 C (14 F)** | 57.95 V | 10 panels | 579.5 V | 17 panels |
| **0 C (32 F)** | 56.25 V | 10 panels | 562.5 V | 17 panels |
| **25 C (77 F STC)** | 52.0 V | 11 panels | 572.0 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ?

Alternative CEC solar modules from competing brands near HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ (420.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS1Y-410MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-410ms/) CSI Solar Co Ltd | 410.0 W | -10.0 W | 52.7 V | 21.03% | 94.1% |
| [**DualSun SAS DualSun 420M-144-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/) DualSun SAS | 420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| [**Auxin Solar AXNG1M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410b/) Auxin Solar | 410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
| [**Auxin Solar AXNG1M410W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410w/) Auxin Solar | 410.0 W | -10.0 W | 49.47 V | 20.92% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ (420.0 W STC, 52.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ reaches 59.65 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 469 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (469 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ 8 kW Residential Fit

Needs 20 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ PTC wattage (381.0 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 381.0 W PTC (90.7% retention) across HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ's 2.18 m2 aperture.

### Who should skip HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ panels (469 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-410MS.

### What is the 1,000 V commercial string limit for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ?

On 1,000 V commercial inverters at -10 C (57.95 V cold Voc), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ fits up to 17 panels per series string.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, CSI Solar Co Ltd CS1Y-410MS specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)