---
title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (405.0W, 49.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s405ni/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI: 405.0W STC, 49.4V Voc, 20-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI is a 405.0 W STC (368.2 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 19.85% efficiency, 49.4 V Voc at 25 C, and 55.26 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 368.2 W

- **Voc @ 25C** : 49.4 V

- **Efficiency** : 19.85%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from HYUNDAI ENERGY SOLUTIONS CO LTD and peers, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI stands 5.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (368.2 W real-world rating). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Higher 49.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI (405.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,028

### 19.85% Aperture Efficiency

Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.26 V at -10 C (552.6 V string) and 56.94 V at -20 C (10 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 40.8 m2 (439 sq ft) producing 7,364 W PTC; NEC 690.8 OCPD floor is 16.11 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.339/100) * (-10 - 25)) = 55.26 V | OCPD = 1.56 * 10.33 = 16.11 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI: Voc=49.4 V, beta_Voc=-0.339%/C, Isc=10.33 A, STC=405.0 W, Area=2.04 m2.

**Result:** 10 panels max on 600 V (552.6 V); 20 panels for 8 kW (439 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 368.2 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.1 V / 9.87 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.339 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.85% (2.04 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 329 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 439 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 549 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI mechanical and cell layout.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400NI** | 400.0 W | 363.4 W | 49.1 V | 40.8 V | 19.61% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI** | 405.0 W | 368.2 W | 49.4 V | 41.1 V | 19.85% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI (55.26 V at 14 F).

Computed from Voc=49.4V and beta_Voc=-0.339%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.94 V | 10 panels | 569.4 V | 17 panels |
| **-10 C (14 F)** | 55.26 V | 10 panels | 552.6 V | 18 panels |
| **0 C (32 F)** | 53.59 V | 11 panels | 589.5 V | 18 panels |
| **25 C (77 F STC)** | 49.4 V | 12 panels | 592.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.15% | 93.4% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-bf-dg/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 20.05% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc-bf/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.76% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-405l-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 405.0 W | Tie (0 W) | 49.45 V | 19.76% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI (405.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI reaches 56.94 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI 8 kW Residential Fit

Needs 20 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 368.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI's 10.33 A short-circuit current by 1.56 equals 16.11 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.26 V cold Voc at 14 F and handles 10.33 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI at 10 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)
