# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI is a 390.0 W STC (354.6 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.31% efficiency, 48.5 V Voc at 25 C, and 54.19 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 354.6 W

- **Voc @ 25C** : 48.5 V

- **Efficiency** : 19.31%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI (Mono-c-Si) residential solar systems.

Homeowners evaluating HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI need 16 panels for 6 kW or 21 panels (457 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (457 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.335%/C) pushes open-circuit voltage to 54.19 V at 14 F and 55.81 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI (390.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,704

### 19.31% Aperture Efficiency

Power density 193.1 W/m2 (0.60 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.19 V at -10 C (596.1 V string) and 55.81 V at -20 C (10 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 42.4 m2 (457 sq ft) producing 7,447 W PTC; NEC 690.8 OCPD floor is 15.88 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.5 * (1 + (-0.335/100) * (-10 - 25)) = 54.19 V | OCPD = 1.56 * 10.18 = 15.88 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI: Voc=48.5 V, beta_Voc=-0.335%/C, Isc=10.18 A, STC=390.0 W, Area=2.02 m2.

**Result:** 11 panels max on 600 V (596.1 V); 21 panels for 8 kW (457 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI including Isc (10.18 A), Voc (48.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 354.6 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.18 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.2 V / 9.72 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.335 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.31% (2.02 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 348 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 457 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 565 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380VI** | 380.0 W | 345.2 W | 47.9 V | 39.6 V | 18.81% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385VI** | 385.0 W | 349.9 W | 48.2 V | 39.9 V | 19.06% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI** | 390.0 W | 354.6 W | 48.5 V | 40.2 V | 19.31% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395VI** | 395.0 W | 359.3 W | 48.8 V | 40.5 V | 19.55% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI (48.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.5V and beta_Voc=-0.335%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.81 V | 10 panels | 558.1 V | 17 panels |
| **-10 C (14 F)** | 54.19 V | 11 panels | 596.1 V | 18 panels |
| **0 C (32 F)** | 52.56 V | 11 panels | 578.2 V | 19 panels |
| **25 C (77 F STC)** | 48.5 V | 12 panels | 582.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI?

Four comparable CEC modules such as CSI Solar Co Ltd CS3U-390MS (390.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-390MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-390ms/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | -5.0 W | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | -5.0 W | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h/) Boviet Solar Technology Co Ltd | 385.0 W | -5.0 W | 48.45 V | 19.35% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI (390.0 W STC, 48.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI reaches 55.81 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 457 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (457 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI 8 kW Residential Fit

Needs 21 modules (457 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 354.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI PTC wattage (354.6 W) lower than STC (390.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 354.6 W PTC (90.9% retention) across HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI's 2.02 m2 aperture.

### Who should skip HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI panels (457 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-390MS.

### What is the 1,000 V commercial string limit for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI?

On 1,000 V commercial inverters at -10 C (54.19 V cold Voc), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI fits up to 18 panels per series string.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, CSI Solar Co Ltd CS3U-390MS specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)