title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (360.0W, 47.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s360ri/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI: 360.0W STC, 47.4V Voc, 23-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI is a 360.0 W STC (327.0 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.4% efficiency, 47.4 V Voc at 25 C, and 52.81 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 360.0 W

- **PTC Wattage** : 327.0 W

- **Voc @ 25C** : 47.4 V

- **Efficiency** : 18.4%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 360.0 W STC and 327.0 W PTC, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI sits -25.0 W vs all-CEC median (below all-CEC median; higher than 41.3% of peers) among 21,677 listed modules. Power density reaches 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). Mid-range 47.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer CertainTeed CT360M11-03 rates 360.0 W.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI (360.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,385 / 21,677

### 360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,501

### 18.4% Aperture Efficiency

Power density 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.81 V at -10 C (580.9 V string) and 54.35 V at -20 C (11 max).

 8 kW Reference Array

### 23 Panels = 8,280 W STC

Occupies 45.0 m2 (484 sq ft) producing 7,521 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.4 * (1 + (-0.326/100) * (-10 - 25)) = 52.81 V | OCPD = 1.56 * 9.7 = 15.13 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI: Voc=47.4 V, beta_Voc=-0.326%/C, Isc=9.7 A, STC=360.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (580.9 V); 23 panels for 8 kW (484 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 327.0 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 39.1 V / 9.2 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.326 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.4% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.12 kW | 358 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 23 | 8.28 kW | 484 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 28 | 10.08 kW | 590 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI mechanical and cell layout.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350RI** | 350.0 W | 317.6 W | 47.1 V | 38.7 V | 17.89% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355RI** | 355.0 W | 322.3 W | 47.3 V | 38.9 V | 18.15% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI** | 360.0 W | 327.0 W | 47.4 V | 39.1 V | 18.4% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365RI** | 365.0 W | 332.0 W | 47.6 V | 39.3 V | 18.66% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370RI** | 370.0 W | 336.7 W | 47.8 V | 39.5 V | 18.92% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI (52.81 V at 14 F).

Computed from Voc=47.4V and beta_Voc=-0.326%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.35 V | 11 panels | 597.9 V | 18 panels |
| **-10 C (14 F)** | 52.81 V | 11 panels | 580.9 V | 18 panels |
| **0 C (32 F)** | 51.26 V | 11 panels | 563.9 V | 19 panels |
| **25 C (77 F STC)** | 47.4 V | 12 panels | 568.8 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI in nameplate wattage and Voc, starting with CertainTeed CT360M11-03.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CT360M11-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct360m11-03/) CertainTeed | 360.0 W | Tie (0 W) | 47.4 V | 18.72% | 92.3% |
| [**AXITEC AC-360M/72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360m-72s/) AXITEC | 360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| [**AXITEC AC-360M/72V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-360m-72v/) AXITEC | 360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| [**Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development-co-ltd/anhui-rinengzhongtian-semiconductor-development-co-ltd-qjm360-72/) Anhui Rinengzhongtian Semiconductor Development Co Ltd | 360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI (360.0 W STC, 47.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI reaches 54.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 484 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (484 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI 8 kW Residential Fit

Needs 23 modules (484 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT360M11-03.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 327.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI cold Voc rises from 47.4 V to 52.81 V (beta_Voc -0.326%/C), capping a 600 V string at 11 panels (580.9 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI need?

An 8 kW DC system uses 23 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI modules (8,280 W STC / 7,521 W PTC), covering roughly 484 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI compare against CertainTeed CT360M11-03?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI outputs 360.0 W STC (47.4 V Voc, rank #12,385 of 21,677), while CertainTeed CT360M11-03 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, CertainTeed CT360M11-03 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)