title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (355.0W, 47.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s355ki-bk/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK): 355.0W STC, 47.3V Voc, 23-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) is a 355.0 W STC (321.7 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 18.15% efficiency, 47.3 V Voc at 25 C, and 52.61 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 355.0 W

- **PTC Wattage** : 321.7 W

- **Voc @ 25C** : 47.3 V

- **Efficiency** : 18.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) (Mono-c-Si) residential solar systems.

Homeowners evaluating HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) need 17 panels for 6 kW or 23 panels (484 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (484 sq ft). Under NEC 690.7(A), beta_Voc (-0.321%/C) pushes open-circuit voltage to 52.61 V at 14 F and 54.13 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) (355.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.

Rank #12,724 / 21,677

### 355.0 W STC · Higher Than 39.9%

355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,882

### 18.15% Aperture Efficiency

Power density 181.5 W/m2 (1.76 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.61 V at -10 C (578.7 V string) and 54.13 V at -20 C (11 max).

 8 kW Reference Array

### 23 Panels = 8,165 W STC

Occupies 45.0 m2 (484 sq ft) producing 7,399 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.3 * (1 + (-0.321/100) * (-10 - 25)) = 52.61 V | OCPD = 1.56 * 9.7 = 15.13 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK): Voc=47.3 V, beta_Voc=-0.321%/C, Isc=9.7 A, STC=355.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (578.7 V); 23 panels for 8 kW (484 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) including Isc (9.7 A), Voc (47.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 355.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 321.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.9 V / 9.1 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.321 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.15% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.04 kW | 358 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 23 | 8.16 kW | 484 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 29 | 10.29 kW | 611 sq ft | $2,575 | $4,355 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350KI(BK)** | 350.0 W | 317.1 W | 47.1 V | 38.7 V | 17.89% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)** | 355.0 W | 321.7 W | 47.3 V | 38.9 V | 18.15% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360KI(BK)** | 360.0 W | 326.4 W | 47.4 V | 39.1 V | 18.4% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) (47.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=47.3V and beta_Voc=-0.321%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.13 V | 11 panels | 595.4 V | 18 panels |
| **-10 C (14 F)** | 52.61 V | 11 panels | 578.7 V | 19 panels |
| **0 C (32 F)** | 51.1 V | 11 panels | 562.1 V | 19 panels |
| **25 C (77 F STC)** | 47.3 V | 12 panels | 567.6 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612P-355 (355.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612P-355**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612p-355/) Boviet Solar Technology Co Ltd | 355.0 W | Tie (0 W) | 47.3 V | 18.3% | 92.6% |
| [**CertainTeed CT355M00-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct355m00-01/) CertainTeed | 355.0 W | Tie (0 W) | 47.3 V | 19.61% | 92.0% |
| [**CertainTeed CT355M10-01**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct355m10-01/) CertainTeed | 355.0 W | Tie (0 W) | 47.3 V | 19.61% | 92.0% |
| [**AXITEC AC-355M/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-355m-156-72s/) AXITEC | 355.0 W | Tie (0 W) | 47.4 V | 18.3% | 91.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) (355.0 W STC, 47.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) reaches 54.13 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 484 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (484 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) 8 kW Residential Fit

Needs 23 modules (484 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-355.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 321.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) PTC wattage (321.7 W) lower than STC (355.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 321.7 W PTC (90.6% retention) across HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)'s 1.956 m2 aperture.

### Who should skip HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) panels (484 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612P-355.

### What is the 1,000 V commercial string limit for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK)?

On 1,000 V commercial inverters at -10 C (52.61 V cold Voc), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK) fits up to 19 panels per series string.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Boviet Solar Technology Co Ltd BVM6612P-355 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK).

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)