title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (350.0W, 47.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s350ti/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI: 350.0W STC, 47.1V Voc, 23-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI is a 350.0 W STC (317.5 W PTC) Mono-c-Si solar module ranking #13,031 of 21,677 CEC listings (below all-CEC median; higher than 38.6% of peers). It delivers 17.89% efficiency, 47.1 V Voc at 25 C, and 52.05 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 350.0 W

- **PTC Wattage** : 317.5 W

- **Voc @ 25C** : 47.1 V

- **Efficiency** : 17.89%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI (350.0 W STC) vs. CSI Solar Co Ltd CS3U-350P-AG across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI pairs typical 90.7% PTC-to-STC thermal output (317.5 W real-world rating) with 47.1 V nominal Voc. An 8 kW residential build (8,050 W DC, 7,302 W PTC) saves ~$2,015/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3U-350P-AG offers a 350.0 W alternative.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI at 350.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI on STC wattage, thermal PTC/STC retention, and 17.89 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #13,031 / 21,677

### 350.0 W STC · Higher Than 38.6%

350.0 W STC (-35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,240

### 17.89% Aperture Efficiency

Power density 178.9 W/m2 (2.02 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.05 V at -10 C (572.5 V string) and 53.46 V at -20 C (11 max).

 8 kW Reference Array

### 23 Panels = 8,050 W STC

Occupies 45.0 m2 (484 sq ft) producing 7,302 W PTC; NEC 690.8 OCPD floor is 14.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.1 * (1 + (-0.3/100) * (-10 - 25)) = 52.05 V | OCPD = 1.56 * 9.6 = 14.98 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI: Voc=47.1 V, beta_Voc=-0.3%/C, Isc=9.6 A, STC=350.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (572.5 V); 23 panels for 8 kW (484 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 350.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 317.5 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.7 V / 9.0 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.3 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.89% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (484 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 18 | 6.3 kW | 379 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 23 | 8.05 kW | 484 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 29 | 10.15 kW | 611 sq ft | $2,540 | $4,296 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI (beta_Voc -0.3%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.1V and beta_Voc=-0.3%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.46 V | 11 panels | 588.1 V | 18 panels |
| **-10 C (14 F)** | 52.05 V | 11 panels | 572.5 V | 19 panels |
| **0 C (32 F)** | 50.63 V | 11 panels | 556.9 V | 19 panels |
| **25 C (77 F STC)** | 47.1 V | 12 panels | 565.2 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI matched near 350.0 W STC and 47.1 V Voc, led by CSI Solar Co Ltd CS3U-350P-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-350P-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-350p-ag/) CSI Solar Co Ltd | 350.0 W | Tie (0 W) | 46.6 V | 18.23% | 92.3% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-350w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 350.0 W | Tie (0 W) | 47.64 V | 18.2% | 91.5% |
| [**Centrosolar America EM72 350BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350bw/) Centrosolar America | 350.0 W | Tie (0 W) | 47.64 V | 18.2% | 91.5% |
| [**Centrosolar America EM72 350SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-em72-350sw/) Centrosolar America | 350.0 W | Tie (0 W) | 47.64 V | 18.2% | 91.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI (350.0 W STC, 47.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI reaches 53.46 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 484 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (484 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI 8 kW Residential Fit

Needs 23 modules (484 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-350P-AG.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 317.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI's 9.6 A short-circuit current by 1.56 equals 14.98 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.05 V cold Voc at 14 F and handles 9.6 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI at 11 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, CSI Solar Co Ltd CS3U-350P-AG specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)