title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (315.0W, 45.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s315ri/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI: 315.0W STC, 45.7V Voc, 26-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI is a 315.0 W STC (279.6 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.1% efficiency, 45.7 V Voc at 25 C, and 51.63 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 315.0 W

- **PTC Wattage** : 279.6 W

- **Voc @ 25C** : 45.7 V

- **Efficiency** : 16.1%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 315.0 W STC and 279.6 W PTC, HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI sits -70.0 W vs all-CEC median (below all-CEC median; higher than 27.3% of peers) among 21,677 listed modules. Power density reaches 161.0 W/m2 (3.81 percentage points below 19.91% CEC median). Mid-range 45.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Centrosolar America EP72 315BW rates 315.0 W.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI (315.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,387 / 21,677

### 315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,982

### 16.1% Aperture Efficiency

Power density 161.0 W/m2 (3.81 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.63 V at -10 C (567.9 V string) and 53.33 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,190 W STC

Occupies 50.9 m2 (547 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.7 * (1 + (-0.371/100) * (-10 - 25)) = 51.63 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI: Voc=45.7 V, beta_Voc=-0.371%/C, Isc=9.0 A, STC=315.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (567.9 V); 26 panels for 8 kW (547 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 279.6 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.4 V / 8.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.371 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.1% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.3 kW | 421 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 26 | 8.19 kW | 547 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 32 | 10.08 kW | 674 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Consolidated HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI mechanical and cell layout.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S305RI** | 305.0 W | 270.4 W | 45.3 V | 37.0 V | 15.59% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S310RI** | 310.0 W | 275.0 W | 45.5 V | 37.2 V | 15.85% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI** | 315.0 W | 279.6 W | 45.7 V | 37.4 V | 16.1% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S320RI** | 320.0 W | 284.2 W | 45.9 V | 37.6 V | 16.36% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI (51.63 V at 14 F).

Computed from Voc=45.7V and beta_Voc=-0.371%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.33 V | 11 panels | 586.6 V | 18 panels |
| **-10 C (14 F)** | 51.63 V | 11 panels | 567.9 V | 19 panels |
| **0 C (32 F)** | 49.94 V | 12 panels | 599.3 V | 20 panels |
| **25 C (77 F STC)** | 45.7 V | 13 panels | 594.1 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI in nameplate wattage and Voc, starting with Centrosolar America EP72 315BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America EP72 315BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep72-315bw/) Centrosolar America | 315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| [**Centrosolar America EP72 315SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep72-315sw/) Centrosolar America | 315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| [**GCL System Integration Technology Co Ltd GCL-P6/72315**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-72315/) GCL System Integration Technology Co Ltd | 315.0 W | Tie (0 W) | 45.6 V | 16.23% | 90.5% |
| [**Boviet Solar Technology Co Ltd BVM6612M-315**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-315/) Boviet Solar Technology Co Ltd | 315.0 W | Tie (0 W) | 46.1 V | 16.23% | 90.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI (315.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI reaches 53.33 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI 8 kW Residential Fit

Needs 26 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EP72 315BW.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI cold Voc rises from 45.7 V to 51.63 V (beta_Voc -0.371%/C), capping a 600 V string at 11 panels (567.9 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI need?

An 8 kW DC system uses 26 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI modules (8,190 W STC / 7,270 W PTC), covering roughly 547 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI compare against Centrosolar America EP72 315BW?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI outputs 315.0 W STC (45.7 V Voc, rank #15,387 of 21,677), while Centrosolar America EP72 315BW delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Centrosolar America EP72 315BW specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)