# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG is a 263.0 W STC (235.6 W PTC) Mono-c-Si solar module ranking #19,144 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.26% efficiency, 37.8 V Voc at 25 C, and 42.58 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 263.0 W

- **PTC Wattage** : 235.6 W

- **Voc @ 25C** : 37.8 V

- **Efficiency** : 16.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG (Mono-c-Si) residential solar systems.

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG delivers 162.6 W/m2 (3.65 percentage points below 19.91% CEC median) and typical 89.6% PTC-to-STC thermal output (235.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft). At -4 F (-20 C), string voltage climbs to 43.94 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Centrosolar America TM6 265xx (265.0 W).

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG Fall Across Listed CEC Models?

Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG (263.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG?

Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG across nameplate watts, 89.6% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG?

Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.

Rank #19,144 / 21,677

### 263.0 W STC · Higher Than 11.7%

263.0 W STC (-122.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,710

### 16.26% Aperture Efficiency

Power density 162.6 W/m2 (3.65 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.58 V at -10 C (596.1 V string) and 43.94 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,153 W STC

Occupies 50.1 m2 (540 sq ft) producing 7,304 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.8 * (1 + (-0.361/100) * (-10 - 25)) = 42.58 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG: Voc=37.8 V, beta_Voc=-0.361%/C, Isc=9.0 A, STC=263.0 W, Area=1.617 m2.

**Result:** 14 panels max on 600 V (596.1 V); 31 panels for 8 kW (540 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG?

Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG including Isc (9.0 A), Voc (37.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 263.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 235.6 W (89.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.0 V / 8.5 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.361 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.26% (1.617 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.05 kW | 400 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 31 | 8.15 kW | 540 sq ft | $2,040 | $3,449 |
| **10 kW Class** | 39 | 10.26 kW | 679 sq ft | $2,568 | $4,342 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG series guide.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S250MG** | 250.0 W | 225.7 W | 37.5 V | 31.1 V | 15.46% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S253MG** | 253.0 W | 228.5 W | 37.6 V | 31.3 V | 15.65% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255MG** | 255.0 W | 230.4 W | 37.7 V | 31.3 V | 15.77% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S258MG** | 258.0 W | 233.2 W | 37.7 V | 31.4 V | 15.96% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260MG** | 260.0 W | 235.0 W | 37.8 V | 31.4 V | 16.08% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG** | 263.0 W | 235.6 W | 37.8 V | 31.0 V | 16.26% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265MG** | 265.0 W | 237.5 W | 37.9 V | 31.2 V | 16.39% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S268MG** | 268.0 W | 240.2 W | 38.0 V | 31.2 V | 16.57% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S270MG** | 270.0 W | 242.1 W | 38.1 V | 31.4 V | 16.7% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S273MG** | 273.0 W | 244.9 W | 38.1 V | 31.6 V | 16.88% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG (37.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.8V and beta_Voc=-0.361%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.94 V | 13 panels | 571.2 V | 22 panels |
| **-10 C (14 F)** | 42.58 V | 14 panels | 596.1 V | 23 panels |
| **0 C (32 F)** | 41.21 V | 14 panels | 576.9 V | 24 panels |
| **25 C (77 F STC)** | 37.8 V | 15 panels | 567.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG?

Four comparable CEC modules such as Centrosolar America TM6 265xx (265.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America TM6 265xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6-265xx/) Centrosolar America | 265.0 W | +2.0 W | 38.0 V | 16.22% | 90.9% |
| [**Centrosolar America TM6S 265xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6s-265xx/) Centrosolar America | 265.0 W | +2.0 W | 38.0 V | 16.22% | 90.9% |
| [**Auxin Solar AXN6M610T260**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m610t260/) Auxin Solar | 260.0 W | -3.0 W | 37.8 V | 15.87% | 89.6% |
| [**CSI Solar Co Ltd CS6P-260M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-260m/) CSI Solar Co Ltd | 260.0 W | -3.0 W | 37.8 V | 16.79% | 91.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG (263.0 W STC, 37.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG reaches 43.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG 8 kW Residential Fit

Needs 31 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,040/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 265xx.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 235.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG cold Voc rises from 37.8 V to 42.58 V (beta_Voc -0.361%/C), capping a 600 V string at 14 panels (596.1 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG need?

An 8 kW DC system uses 31 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG modules (8,153 W STC / 7,304 W PTC), covering roughly 540 sq ft and saving ~$2,040/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG compare against Centrosolar America TM6 265xx?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG outputs 263.0 W STC (37.8 V Voc, rank #19,144 of 21,677), while Centrosolar America TM6 265xx delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Centrosolar America TM6 265xx specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)