title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (224.0W, 37.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-s224sg/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG: 224.0W STC, 37.1V Voc, 36-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG is a 224.0 W STC (196.9 W PTC) Mono-c-Si solar module ranking #20,751 of 21,677 CEC listings (below all-CEC median; higher than 4.3% of peers). It delivers 15.44% efficiency, 37.1 V Voc at 25 C, and 42.89 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 224.0 W

- **PTC Wattage** : 196.9 W

- **Voc @ 25C** : 37.1 V

- **Efficiency** : 15.44%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG Compare Against Peer CEC Listings?

How HYUNDAI ENERGY SOLUTIONS CO LTD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG handles rooftop heat (196.9 W PTC), 8 kW sizing, and cold winter string voltage.

HYUNDAI ENERGY SOLUTIONS CO LTD builds the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG (Mono-c-Si) as a compact residential or specialty off-grid module delivering 154.4 W/m2 (4.47 percentage points below 19.91% CEC median). Compared against Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 (225.0 W), this model holds typical 87.9% PTC-to-STC thermal output (196.9 W real-world rating). Lower 37.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.79 A overcurrent floor served by a 15 A breaker.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG Fall Across Listed CEC Models?

Where HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG (224.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG?

Percentile placement of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG across power density (154.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG?

Four critical engineering numbers homeowners and solar installers check first when reviewing HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG specifications.

Rank #20,751 / 21,677

### 224.0 W STC · Higher Than 4.3%

224.0 W STC (-161.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,080

### 15.44% Aperture Efficiency

Power density 154.4 W/m2 (4.47 percentage points below 19.91% CEC median). PTC/STC ratio: 87.9% (rank #21,435).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.89 V at -10 C (557.6 V string) and 44.55 V at -20 C (13 max).

 8 kW Reference Array

### 36 Panels = 8,064 W STC

Occupies 52.2 m2 (562 sq ft) producing 7,088 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.1 * (1 + (-0.446/100) * (-10 - 25)) = 42.89 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG: Voc=37.1 V, beta_Voc=-0.446%/C, Isc=8.2 A, STC=224.0 W, Area=1.451 m2.

**Result:** 13 panels max on 600 V (557.6 V); 36 panels for 8 kW (562 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 224.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 196.9 W (87.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.2 V / 7.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.446 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.44% (1.451 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG (224.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 27 | 6.05 kW | 422 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 36 | 8.06 kW | 562 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 45 | 10.08 kW | 703 sq ft | $2,523 | $4,266 |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG Modules Fit in a Cold-Weather String?

Maximum series module counts for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.1V and beta_Voc=-0.446%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.55 V | 13 panels | 579.1 V | 22 panels |
| **-10 C (14 F)** | 42.89 V | 13 panels | 557.6 V | 23 panels |
| **0 C (32 F)** | 41.24 V | 14 panels | 577.4 V | 24 panels |
| **25 C (77 F STC)** | 37.1 V | 16 panels | 593.6 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG?

Alternative CEC solar modules from competing brands near HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG (224.0 W), including Hanwha Qcells (Qidong) Co Ltd SF220-30-M225.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanwha Qcells (Qidong) Co Ltd SF220-30-M225**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf220-30-m225/) Hanwha Qcells (Qidong) Co Ltd | 225.0 W | +1.0 W | 36.8 V | 13.62% | 90.2% |
| [**Greenlite Solar Canada GLS-220**](https://epri-peac.com/solar-equipment/modules/greenlite-solar-canada/greenlite-solar-canada-gls-220/) Greenlite Solar Canada | 220.0 W | -4.0 W | 37.08 V | 13.63% | 90.0% |
| [**APOS Energy AS220**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as220/) APOS Energy | 220.0 W | -4.0 W | 36.63 V | 13.26% | 89.5% |
| [**Grape Solar GS-P-220-CS**](https://epri-peac.com/solar-equipment/modules/grape-solar/grape-solar-gs-p-220-cs/) Grape Solar | 220.0 W | -4.0 W | 36.6 V | 13.68% | 91.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG (224.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG reaches 44.55 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 36 panels for an 8 kW build require 562 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 36 panels (562 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG 8 kW Residential Fit

Needs 36 modules (562 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd SF220-30-M225.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 196.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG's 8.2 A short-circuit current by 1.56 equals 12.79 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.89 V cold Voc at 14 F and handles 8.2 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG at 13 panels on 600 V.

### Is HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Hanwha Qcells (Qidong) Co Ltd SF220-30-M225 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)