title: "HYUNDAI ENERGY SOLUTIONS CO LTD Specs (310.0W, 45.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-his-m310ri/
description: "CEC datasheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI: 310.0W STC, 45.3V Voc, 26-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI — CEC Solar Module Specifications

Manufacturer: [**HYUNDAI ENERGY SOLUTIONS CO LTD**](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) Registry: **CEC Verified Engineering Specification**

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI is a 310.0 W STC (279.6 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.85% efficiency, 45.3 V Voc at 25 C, and 50.74 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 279.6 W

- **Voc @ 25C** : 45.3 V

- **Efficiency** : 15.85%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI (310.0 W STC) vs. Advance Power API-P310 across 1,407 CEC Multi-c-Si solar modules.

Ranking #15,760 across 21,677 CEC solar panels (below all-CEC median; higher than 25.6% of peers), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI operates as a compact residential or specialty off-grid module sitting 31.2 W above the 278.8 W Multi-c-Si median. Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 90.2% PTC-to-STC thermal output (279.6 W real-world rating), 26 panels occupy 547 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI on STC wattage, thermal PTC/STC retention, and 15.85 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,395

### 15.85% Aperture Efficiency

Power density 158.5 W/m2 (4.06 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.74 V at -10 C (558.1 V string) and 52.29 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.9 m2 (547 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.3 * (1 + (-0.343/100) * (-10 - 25)) = 50.74 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI: Voc=45.3 V, beta_Voc=-0.343%/C, Isc=8.9 A, STC=310.0 W, Area=1.956 m2.

**Result:** 11 panels max on 600 V (558.1 V); 26 panels for 8 kW (547 sq ft).

## What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 279.6 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.0 V / 8.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.343 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.85% (1.956 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (547 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 421 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 547 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 695 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Sibling wattage bins and frame colors grouped with HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI under HYUNDAI ENERGY SOLUTIONS CO LTD to prevent duplicate spec pages.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M300RI** | 300.0 W | 270.3 W | 44.9 V | 35.8 V | 15.34% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M305RI** | 305.0 W | 275.0 W | 45.1 V | 36.0 V | 15.59% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI** | 310.0 W | 279.6 W | 45.3 V | 36.0 V | 15.85% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M315RI** | 315.0 W | 284.3 W | 45.5 V | 36.2 V | 16.1% |
| **HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M320RI** | 320.0 W | 288.9 W | 45.7 V | 36.4 V | 16.36% |

## How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.3V and beta_Voc=-0.343%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.29 V | 11 panels | 575.2 V | 19 panels |
| **-10 C (14 F)** | 50.74 V | 11 panels | 558.1 V | 19 panels |
| **0 C (32 F)** | 49.18 V | 12 panels | 590.2 V | 20 panels |
| **25 C (77 F STC)** | 45.3 V | 13 panels | 588.9 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI matched near 310.0 W STC and 45.3 V Voc, led by Advance Power API-P310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-P310**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p310/) Advance Power | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Auxin Solar AXN6P612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t310/) Auxin Solar | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Chinaland Solar Energy HSE310-72M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse310-72m/) Chinaland Solar Energy | 310.0 W | Tie (0 W) | 45.4 V | 16.06% | 90.3% |
| [**GCL System Integration Technology Co Ltd GCL-P6/72310**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-72310/) GCL System Integration Technology Co Ltd | 310.0 W | Tie (0 W) | 45.4 V | 15.98% | 90.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI (310.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI reaches 52.29 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI 8 kW Residential Fit

Needs 26 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI cold Voc rises from 45.3 V to 50.74 V (beta_Voc -0.343%/C), capping a 600 V string at 11 panels (558.1 V).

### How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI need?

An 8 kW DC system uses 26 HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI modules (8,060 W STC / 7,270 W PTC), covering roughly 547 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI compare against Advance Power API-P310?

HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI outputs 310.0 W STC (45.3 V Voc, rank #15,760 of 21,677), while Advance Power API-P310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare HYUNDAI ENERGY SOLUTIONS CO LTD equipment, Advance Power API-P310 specs, utility payback rates, and NEC string calculators alongside HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI.

[All HYUNDAI ENERGY SOLUTIONS CO LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From HYUNDAI ENERGY SOLUTIONS CO LTD

- [All HYUNDAI ENERGY SOLUTIONS CO LTD Specs](https://epri-peac.com/solar-equipment/brands/hyundai-energy-solutions-co-ltd/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s545bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hin-s520bi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460xi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s460yi/)
- [HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI](https://epri-peac.com/solar-equipment/modules/hyundai-energy-solutions-co-ltd/hyundai-energy-solutions-co-ltd-hig-s455ni/)